Denso BHT-805BWB Скачать руководство пользователя страница 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Barcode Handy Terminal 

BHT-805BWB 

 

User’s Manual

 

Содержание BHT-805BWB

Страница 1: ...Barcode Handy Terminal BHT 805BWB User s Manual...

Страница 2: ...precautions to ensure its products do not infringe upon any patents or other intellectual property rights of other s However DENSO WAVE cannot be responsible for any patent or other intellectual prope...

Страница 3: ...led information on each product Download service Offers downloads of repair modules for the latest BHT Series systems or software and sample programs E mail inquiries Product related queries can be se...

Страница 4: ...ust be performed prior to commencing operation Chapter 3 Basic Operation Describes basic operations performed by the operator and how to make basic changes to settings such as the volume Chapter 4 Sys...

Страница 5: ...k The PDF Bookmark function can be used to jump to the Contents page Procedure 1 Click the Bookmark tab 2 Click to search for the desired item 3 Click the item to be read 3 Click the item to be read 1...

Страница 6: ...ction can be used to jump to the target page by entering words or characters related to the item being searched 1 Click the Search icon Or select Edit Search 2 Enter the word s or character s to be se...

Страница 7: ...es This is an instruction manual used to create handy terminal programs with BHT BASIC BHT BASIC 4 0 Transfer Utility User s Guide This is an instruction manual for software relating to data transfer...

Страница 8: ...those conditions that could cause serious bodily injury or death if the instructions are not followed correctly Alerts you to those conditions that could cause minor bodily injury or substantial prope...

Страница 9: ...high pressure container Doing so could cause the batteries to break generate heat rupture or burn Avoid dropping the battery cartridge or letting it undergo any shock or impact Doing so could cause th...

Страница 10: ...r nearest dealer Failure to do so could cause fire or electrical shock Never use the CU for charging anything other than the specified battery cartridges Doing so could cause heat battery rupture or f...

Страница 11: ...etting them caught in other objects or entangled in rotating machinery Failure to do so could result in accident or injury Never dis assemble Never disassemble or modify the BHT doing so could result...

Страница 12: ...een stored in a hot 50 C to 60 C 122 F to 140 F and humid place allow it to sit at room temperature and humidity for at least one day before use Using the BHT with its inside being hot will result in...

Страница 13: ...deforming its housing resulting in a fire Always use the CU and AC adapter in a well ventilated area Do not place the CU anyplace where it may be subjected to oily smoke or steam e g near a cooking r...

Страница 14: ...INCORPORATED BHT 805BWB Wireless LAN DWWL001 Bluetooth DWBT011 1999 5 K Fran ais Par la pr sente DENSO WAVE INCORPORATED d clare que le terminal BHT 805BWB est dot d un module de connexion un r seau l...

Страница 15: ...mi pr slu n mi ustanoveniami Smernice 1999 5 ES Suomi T ten DENSO WAVE INCORPORATED vakuuttaa ett t m n tuotteen BHT 805BWB sis lt m langaton WLAN moduli tyyppi DWWL001 ja Bluetooth piiri tyyppi DWBT...

Страница 16: ...xv BHT 805BWB...

Страница 17: ...iguration 2 1 1 2 Software Configuration 4 1 2 Component Names and Functions 7 1 2 1 BHT Front Rear 7 1 2 2 Keypad 8 1 2 3 BHT Screen 10 BHT 805BWB Chapter 1 Outline This chapter describes the BHT sys...

Страница 18: ...C 4 0 Development Pack Option and BHT BASIC 4 0 Transfer Utility Option Required for system configuration Host computer BHT CU Wireless LAN access point Bluetooth compatible device Software Ref Page 1...

Страница 19: ...CU 801 RS 232C interface CU 811 Ethernet CU 821 USB interface Connection Cable Option or Commercially Available Product Used to connect the host computer and CU 800 Series Select a cable suited to the...

Страница 20: ...is is an instruction manual used to create handy terminal programs with BHT BASIC BHT BASIC 4 0 Development Pack Option This is a package containing four software products required for BHT Series appl...

Страница 21: ...ored in the user area are run by the system program in order to use the BHT It is necessary to download application programs PD4 and data files product master files etc required to run application pro...

Страница 22: ...eed to display Kanji characters you may delete these JIS font files After deletion the memory area which was occupied by these files can be used as a user area For the deleting procedure refer to Chap...

Страница 23: ...4 System Operation for details on how to operate the SYSTEM MENU 5 Speaker Emits sound 6 IrDA interface port Used to exchange data programs with the optical communication unit CU 800 or other BHTs 7 H...

Страница 24: ...y M1 3 Magic key M2 4 Magic key M3 5 Magic key M4 Each of the M3 and M4 keys is assigned a trigger switch by default The SF ENT Backlight MENU or C key functions can be assigned to these magic keys by...

Страница 25: ...d at user programs Refer to the BHT BASIC Programmer s Manual For BHT 800 Series for further details 9 Power key Turns the BHT power ON or OFF 10 Backspace clear key Deletes the last entered character...

Страница 26: ...ting up the FTP Shows that the CU 811 is connected Blinks when the CU 811 which is not connected tries to connect The icons are displayed in the following order when No response from the CU 811 Waitin...

Страница 27: ...2 Holding the BHT 19 2 4 Initial Setup 20 2 5 Turning OFF the Power 21 2 5 1 Normal Power OFF 21 2 5 2 Turning the Power OFF after Data Back up 21 2 5 3 Auto Power OFF 21 2 5 4 If the BHT Is Shut Down...

Страница 28: ...hargers are used for charging individual batteries and the CH 851 and CH 854 are stand type same type as CU communication unit chargers The charging time is approximately 3 hours The charging time is...

Страница 29: ...ve the battery cartridge cover 2 2 Check the battery cartridge terminals and indication on the BHT unit and then insert the cartridge in the direction indicated by the arrow Point Do not use battery c...

Страница 30: ...r when using the BHT for the first time or when left unused for long periods of time do not remove from the charger for approximately 10 minutes When the BHT is set on the charger the LCD screen will...

Страница 31: ...AC power source 230 V AC The LED will turn red when charging is commenced 3 The LED will turn OFF when charging is complete Point z Charging takes approximately 3 hours z An only slightly discharged...

Страница 32: ...cover tab 1 and then close the battery cartridge cover 2 to lock the cover in position Press the battery cover into place until a click is heard Note The BHT is equipped with a back up battery used to...

Страница 33: ...ke generation blowout or combustion Please read the following item prior to use z Terminate charging if not completed even after the specified time has elapsed Note z The BHT is equipped with a back u...

Страница 34: ...press the ENT key The Battery Voltage screen displays while the keys are pressed About the Battery Level The battery power level indicator does not accurately reflect the battery residual power and s...

Страница 35: ...trap Attach the hand strap to prevent the BHT from being accidentally dropped during use 2 3 1 Attaching the Hand Strap Attach the hand strap as shown below 2 3 2 Holding the BHT Attach the hand strap...

Страница 36: ...ng the numeric keys Ex April 5 2009 14 20 Point Enter the last two digits for the year and enter the time in 24 hour clock format 3 Press the ENT key to set the date and time The screen to the right d...

Страница 37: ...turned ON there are times when a message 2XXX displays asking the user to contact the administrator 2 5 2 Turning the Power OFF after Data Back up 1 Hold down the Power key for at least 3 seconds The...

Страница 38: ...rtridge loaded then unsaved data may be lost Normally shut down refers to 2 5 Turning OFF the Power 1 The right message will appear when you load a charged battery cartridge and turn the BHT on 2 Next...

Страница 39: ...ight may appear The BHT displays the screen for three seconds and then automatically runs the execution program from the beginning The screen may also appear when the calendar clock built in the BHT s...

Страница 40: ...ered 1000 to 1200 is lost Ex SAMPLE1 DAT 01000 01050 SAMPLE1 DAT 01200 01250 SAMPLE1 DAT 01600 01650 SAMPLE2 DAT 00250 00275 SAMPLE3 DAT 00100 00150 2 5 5 If Broken Files Are Found Even broken files c...

Страница 41: ...ings 29 3 4 1 Procedure 29 3 5 Transmitting Data 31 3 5 1 Infrared Communication 32 3 5 2 Wireless Communication 33 Chapter 3 Basic Operation This chapter describes basic operations such as barcode sc...

Страница 42: ...uminate in blue Point The barcode scanning method may differ depending on the application Perform scanning in accordance with the instructions provided in the application User s Manual Note z If requi...

Страница 43: ...forming to the UPC Shipping Container Code PCS value 0 9 or more Minimum narrow bar width 1 2 mm min Barcode surface curvature Scanning may be unsuccessful if the barcode surface is curved Scan the ba...

Страница 44: ...ic keys 1 2 and 0 followed by the Enter key 3 3 Task Selection If a selection item such as 1 XXX 2 XXX with numeric values displays enter the values with the numeric entry keys and then press the Ente...

Страница 45: ...F the vibrator that notifies the user when barcode scanning is complete ON OFF BRIGHTNESS Used to set the backlight brightness of the LCD display The brightness can be adjusted in 5 levels Levels 1 to...

Страница 46: ...ct the item to be changed The selected item is highlighted 3 Use the and cursor keys to select the setting 4 Press any of the following keys to exit the settings screen M1 key long press Backspace cle...

Страница 47: ...ata gathered by the BHT should be promptly uploaded to the host computer 1 To enable wireless LAN communication it is necessary to configure the wireless local area network wireless LAN of both the BH...

Страница 48: ...the vicinity of infrared communication This may result in comunication failure Perform communication in locations where the BHT units will not be exposed to light interference from sources such as int...

Страница 49: ...point to improve communication performance Communication may not be possible at the following locations 1 In the vicinity of devices operating on the same 2 4 GHz waveband as the BHT such as microwav...

Страница 50: ...34 BHT 805BWB...

Страница 51: ...U Configuration 48 4 5 SYSTEM MENU 53 4 5 1 Executing Setup SETUP Menu 53 4 5 2 Executing User Programs EXECUTE PROGRAM Menu 57 4 5 3 Downloading Files DOWNLOAD Menu 58 4 5 4 Uploading Files UPLOAD Me...

Страница 52: ...essage displays on the screen when the BHT is turned on Point By initializing the system all files in the user area are deleted and therefore all files that need to be backed up should be uploaded to...

Страница 53: ...Memory Area Selected for Initialization 2 To delete font files Press the 2 key while holding down the SF key The screen on the right displays Next press the 2 key select 2 WHOLE USER AREA and press th...

Страница 54: ...t font files from deletion When the screen on the right displays select the item and press the ENT key Press the BS C key to return to the screen to select the area for initialization 1 Yes The system...

Страница 55: ...nistrator Note the error number XXXX message displays even although initialization has been completed initialize the BHT again Following initialization all programs and data files stored in the target...

Страница 56: ...ttp www denso wave com en BHT System Update Refer to section 4 5 16 Updating the System MODIFY MENU and update the BHT system Important In order to prevent the battery running low during the system up...

Страница 57: ...llowing Web site http www denso wave com en CU 811 System Update Refer to section 4 5 16 Updating the System MODIFY MENU and update the CU 811 system The CU 811 LED flashes during CU 811 system update...

Страница 58: ...n If no program has been selected at the SYSTEM MENU EXECUTE PROGRAM menu and the BHT power is turned ON control will switch to the directory management program and the first of the programs PD4 regis...

Страница 59: ...ersion In the above case the registration order does not change and therefore MAIN PD4 starts up by pressing the Power key Example 2 When newly downloading USER PD4 after deleting BBBBBBBB DAT In the...

Страница 60: ...rogram has been selected the first registered program from among the programs PD4 registered in the BHT will be executed Refer to the BHT BASIC Programmer s Manual for details 4 3 5 Executing by Remot...

Страница 61: ...upload Remote wake up setting System message file download upload System update Refer to each item at the 4 5 SYSTEM MENU for details of the above operations 4 4 1 Starting Up System Mode Use the foll...

Страница 62: ...will be highlighted SETUP will be highlighted when System Mode is started up 2 Press the ENT key The selected item is set and the next screen displays Press the BS C key to return to the previous scre...

Страница 63: ...o the item to be selected Alternatively press the cursor keys to select the item The selected item will be highlighted 2 Select the setting value with the cursor keys 3 Press the ENT key The selected...

Страница 64: ...reen Select the item with the numerical keys or cursor keys and press the ENT key SYSTEM MENU Executing Programs Refer to section 4 5 2 Executing User Programs Downloading Refer to section 4 5 3 Downl...

Страница 65: ...5 6 System Environment Setting Testing Refer to section 4 5 7 BHT Operation Test System Information Display Refer to section 4 5 8 System Information Downloading Uploading by FTP Refer to section 4 5...

Страница 66: ...50 BHT 805BWB DEVICE MENU Refer to section 4 5 10 Wireless Communication Settings 8 and ENT keys BS C key...

Страница 67: ...key SYSTEM MENU Deleting Program Data Files Refer to section 4 5 11 Deleting Program Data Files Deleting Font Files Refer to section 4 5 12 Deleting Font Files Downloading Uploading the BHT System Pa...

Страница 68: ...eld down BS C key Setting Remote Wake up Refer to section 4 5 14 Setting Remote Wake up Downloading Uploading the System Message File Refer to section 4 5 15 Downloading Uploading System the Message F...

Страница 69: ...lable Available File Copy Clone Files in both the receiving and transmitting devices are identical Default Available Not Available General system setting values excluding the items below Available Ava...

Страница 70: ...ential numbers but date settings can be performed as well Ex The function differentiates between 1 and 000001 2 SOFTWAVE TO CLONE OS YES There are also OS settings and additional files but the aforeme...

Страница 71: ...then press ENT on the transmitting device The data transmission progress status is shown as per the screens below Data transmission complete When flashing data transmission is in progress Master Side...

Страница 72: ...not be copied N Suspend processing OS update not possible when HT HT copy mode designations and initialization are required OS cannot be updated Cloning will be stopped Number of files exceeded Too m...

Страница 73: ...y to return to the SYSTEM MENU 2 Use the cursor keys to select the target program The selected program will be highlighted Use the key to scroll down when more than 18 programs have been downloaded to...

Страница 74: ...file download order Refer to 4 3 Executing User Programs for details Use the following procedure to download files 1 Select 2 DOWNLOAD at the SYSTEM MENU and then press the ENT key The screen on the r...

Страница 75: ...By executing the BHT BASIC 4 0 Transfer Utility or similar program the screen on the right displays and file downloading is commenced Refer to the BHT BASIC 4 0 Transfer Utility User s Guide 4 The scr...

Страница 76: ...le size equals the total file size Press the BS C key to return to the DOWNLOAD menu With this screen displayed on the BHT downloading another new file from the host computer allows the BHT to begin r...

Страница 77: ...Ymodem BHT Ir BHTp Ymodem protocol BHT Ir protocol BHT protocol Interface used Opt Infrared interface Transmit speed 9600 to 460800 Transmission speed corresponding to each protocol Refer to 4 5 6 Sys...

Страница 78: ...3 The screen on the right displays if no files that can be uploaded exist in the user area Press the BS C key to return to the UPLOAD menu 3 The screen on the right displays indicating that the BHT is...

Страница 79: ...e sent file size the total file size units KB displays Press the BS C key to abort the download process and return to the UPLOAD menu 6 When uploading is complete the speaker sounds once and the scree...

Страница 80: ...are facing one another 4 Select 2 DOWNLOAD 2 HT HT COPY at the SYSTEM MENU of the BHT that is downloading to await downloading Refer to 4 5 3 Downloading Files DOWNLOAD Menu for details When copying o...

Страница 81: ...f digits to be read for ITF Minimum number of digits to be read for STF Minimum number of digits to be read for Codabar NW 7 Interface port to be used in user programs Interface port to be used in Sys...

Страница 82: ...le to copy correctly if there is a space at the end Power save mode for wireless module Authentication system WEP Wired Equivalent Privacy enable disable Maximum DHCP IP address acquisition wait time...

Страница 83: ...anning conditions black white inverted label scanning function and decode label and minimum number of scan digits for scan codes ITF STF Codabar 5 COMMUNICATION Sets the communication environment inte...

Страница 84: ...en on the right displays The highlighted program will be the program currently set as the auto start execution program 2 Use the cursor keys to highlight the target program 3 Press the ENT key The sel...

Страница 85: ...ations relating to the LCD contrast Speaker volume Switching between speaker and vibrator Battery voltage level screens 2 STATUS Sets whether to display or hide the system status displayed at the bott...

Страница 86: ...een display OFF Prohibits menu screen display 2 COMPATIBLE MODE Sets compatible mode for screen display with the BHT 100 BHT 300 or BHT 7500 This allows BHT 100 Series BHT 300 Series or BHT 7500 Serie...

Страница 87: ...r 10 x 15 dots 26 x 26 char 9 x 12 dots 20 x 26 char 12 x 12 dots 20 x 20 char 12 x 16 dots Standard font 8 x 8 char 28 x 40 dots 10 x 13 char 24 x 24 dots 15 x 20 char 16 x 16 dots 8 x 10 char 30 x 3...

Страница 88: ...e BHT Communication link with the CU 811 Displays cyclically when the BHT receives no response from the CU 811 or when it is waiting for the link to be established with or severed from the CU 811 Radi...

Страница 89: ...canning ON Enables black white inverted label scanning OFF Disables black white inverted label scanning Point By enabling black white inverted label scanning it will also be possible to scan black whi...

Страница 90: ...hen scanning or incorrectly scanning depending on how barcodes are scanned or the quality of barcodes On the other hand setting a large number will decrease the possibility of such errors 5 Setting th...

Страница 91: ...the BS C key to return to the SYSTEM MENU 1 OPTICAL Infrared communication parameters 1 Select 1 OPTICAL at the SET COMMUNICATION menu and then press the ENT key The SET OPTICAL menu screen on the ri...

Страница 92: ...out length in seconds to be applied when a link is to be established 4 FIELD SPACE Specifies handling for trailing spaces in fields To trim trailing spaces in fields select Ignore and to retain them a...

Страница 93: ...FILE statement in BHT BASIC 2 BHT Protocol Selects the BHT protocol when uploading downloading in System Mode or for the execution of the XFILE statement in BHT BASIC 3 BHT Ir Protocol Selects the BHT...

Страница 94: ...er None should normally be selected To add the BHT ID number to the transfer tool select Add This setting is not supported Changing this setting has no result 4 INTERVAL Specifies the retry interval w...

Страница 95: ...re is no need to edit the current setting press the ENT key only Point ID numbers should consist of a five digit decimal character string The entry range is from 00001 to 65534 If the entry value is l...

Страница 96: ...ey definition screen 6 BS C KEY Displays the BS C key definition screen 7 MENU KEY Displays the M1 M4 key menu definition screen Refer to the following section for details of the above items Press the...

Страница 97: ...will return to the SET KEY menu Magic keys M1 to M4 Magic keys M1 to M4 can be set to function as the trigger switch SF key ENT key backlight function ON OFF key MENU key or BS C key If the M1 key is...

Страница 98: ...of the current settings 4 Enter the desired numeric values Numeric values can be entered between 1 and 255 x 100 ms 5 Press the ENT key Defining the MENU key setting The M1 to M4 keys can be set as m...

Страница 99: ...tails of the above items Press the BS C key to return to the SET SYSTEM menu 1 SET TCP IP Setting the TCP IP 1 Select 1 SET TCP IP at the SET TCP IP menu and then press the ENT key The SET TCP IP menu...

Страница 100: ...If the IP address subnet mask and default gateway are all set to 0 0 0 0 DHCP is enabled Press the BS C key to return to the SET TCP IP menu 3 TIMEOUT Setting the timeout only when COM1 selected Sele...

Страница 101: ...word 4 DEFAULT DIR Specifies an initial directory through which the FTP server will search for files for transfer first when the FTP client establishes a connection to the server To change the setting...

Страница 102: ...s will be written over the existing files Append Uploaded files will be appended to the existing files 5 VERBOSE MODE Specifies the command response display when using FTP ON Displays a message to the...

Страница 103: ...er than 0 0 0 0 the DHCP does not display on the screen shown on the right 1 TIMEOUT Sets the timeout for acquiring the IP configuration from the DHCP server The entry range is from 00001 to 32767 sec...

Страница 104: ...function Point When the power is turned ON the resume function starts the BHT from the position in the program screen where the BHT power was last turned OFF 9 defragging the drive Use the following p...

Страница 105: ...lay The highlighted setting will be the current setting 1 TRANSPORT Selects the communication path for communicating with the BHT Manager 2 REMOTE WAKEUP Sets the PRC remote wakeup 3 SCHEDULED WAKEUP...

Страница 106: ...explains only the operation of this menu and an outline of the settings 1 Select 3 OPERATION LOG from the SET SYSTEM Menu 2 2 and then press the ENT key The OPERATION LOG settings menu will display Th...

Страница 107: ...d write test 3 BEEPER Selects the speaker scale test 4 AGING Selects the aging test 5 LCD Selects the LCD and indicator LED tests 6 FILE Checks the file information 7 COMMUNICATION Selects the communi...

Страница 108: ...canned barcode type number of digits and data display at the screen Ensure that the barcode data and screen display match Press the BS C key to return to the TEST menu Barcode Type and Corresponding C...

Страница 109: ...barcode scanning test options to be set Details of option settings are as follows 1 Add on ON OFF The highlighted settings will be the current settings 1 Add on Enables disables add ons 1 Enabling di...

Страница 110: ...pacity unit kilobytes YYYYY Total RAM capacity unit kilobytes If any error is detected the BHT speaker beeps three times displays a message similar to that shown on the right and aborts the memory tes...

Страница 111: ...F Scale Frequency Hz do 523 1046 2093 4186 re 587 1174 2349 mi 659 1318 2637 fa 698 1396 2793 sol 783 1567 3135 la 880 1760 3520 ti 987 1975 3951 4 Aging test Use the following procedure to perform an...

Страница 112: ...return to the TEST menu 2 Press the ENT key The entire screen turns black and the indicator LED illuminates in green Press the BS C key to return to the previous screen Press and hold the BS C key or...

Страница 113: ...ST menu 5 Press the ENT key The entire screen turns an even lighter shade of gray Press the BS C key to return to the previous screen Press and hold the BS C key or press the SF key and BS C key simul...

Страница 114: ...e entire screen turns green and at the same time the indicator LED turns green Press the BS C key to return to the previous screen Press and hold the BS C key or press the SF key and BS C key simultan...

Страница 115: ...displays around the screen Press the BS C key to return to the previous screen Press and hold the BS C key or press the SF key and BS C key simultaneously to return to the TEST menu 11 Press the ENT k...

Страница 116: ...d each time the M1 key is pressed TYPE Sorts files by type BROKEN Displays broken files in descending order BASIC Displays files in the following order B BASIC files C C data files None Shared files a...

Страница 117: ...screen to the right will appear displaying the file size and creation date 2 Press the F1 key to play the file Press the F1 key while the file is playing to stop the file and return to the previous s...

Страница 118: ...on date and a preview image 2 Press the F1 key to display the image in full screen If the actual image is larger than the screen the image will be displayed at the actual size centered on the top left...

Страница 119: ...n press the ENT key Press the BS C key to return to the previous screen BASIC User Program PD3 PD4 1 Use the cursor keys to select a PD3 PD4 file and then press the ENT key Press the BS C key to retur...

Страница 120: ...F1 key to display the next screen To return to the previous screen press the F1 key again or press the BS C key In addition when there are four or more fields MORE FIELD LEN and a guide will display I...

Страница 121: ...ve items Press the BS C key to return to the TEST menu Infrared Communication Test 1 Arrange two BHTs one as a master station and the other as a slave station to be tested with their IrDA interface po...

Страница 122: ...as follows X X 1 The received data is different from the sent data 2 A timeout has occurred during standby for data reception 1 9600 bps 2 115200 bps 3 460800 bps Press the BS C key to return to the T...

Страница 123: ...ssing individual keys displays the identifier letters in the positions pre assigned to those keys on the LCD as well as sounding the speaker or activating the vibrator As long as the individual key is...

Страница 124: ...ey to return to the TEST menu 1 RUN PING PING Test Screen 1 Select 1 RUN PING at the TEST PING menu and then press the ENT key The current setting values display and the BHT waits for the transmission...

Страница 125: ...ays the BHT IP address during the PING test only Messages displayed during PING test displayed in center of screen Waiting Setting up the PING test Opening device Opening devices Routing TCP IP Connec...

Страница 126: ...be set and then press the ENT key The mode changes to entry mode and the cursor displays Use the cursor keys to highlight the 6 SEND TYPE setting 3 Enter the setting values with the numerical keys and...

Страница 127: ...nding an echo request PING waits for an echo reply to be received or for a timeout to occur Following that PING waits for the period specified at INTERVAL and then sends the next PING echo request For...

Страница 128: ...CE PING Device Setting Screen 1 Select 3 SET DEVICE at the TEST PING menu and then press the ENT key The TCP IP communication device link layer and transmission speed display Press the BS C key to ret...

Страница 129: ...font type and version Press the BS C key to return to the SYSTEM MENU License List Press the F1 key at the LICENCE INFORMATION screen to display a license list as shown on the right The license list...

Страница 130: ...d 1 Use the cursor keys to highlight the name of a function that has not been registered and then press the ENT key to display the license registration screen shown on the right PRODUCT ID Product ID...

Страница 131: ...press the ENT key The SYSTEM INFORMATION screen on the right displays 3 Press the M2 key The CU 811 INFORMATION screen displays SYSTEM Ver System program information MAC ADDRESS MAC address Press the...

Страница 132: ...etails of the above items Press the BS C key to return to the SYSTEM MENU 1 Downloading by FTP 1 Select 1 DOWNLOAD at the FTP MENU and then press the ENT key The screen on the right displays 1 DIR FIL...

Страница 133: ...o return to the FTP MENU screen DIR FILE entry box The FTP client will interpret a character string entered into this box as a directory name at first and will therefore send a Change Directory reques...

Страница 134: ...s screen 2 Use the cursor keys to highlight the item to be set and then press the ENT key When 1 DIR FILE is Selected The mode changes to entry mode and the cursor displays allowing directory and file...

Страница 135: ...name specified in the DIR FILE entry box the FTP client will upload with the file name specified in the DIR FILE entry box If the ENT key is pressed without entering a character string in the DIR FILE...

Страница 136: ...uring execution of an FTP command FTP opened Connection has been established by FTP Illegal text format The format of the received text is illegal Opening device Opening a device Out of memory The mem...

Страница 137: ...losing data connection 227 Entering Passive Mode 230 User logged in Proceed 250 Requested file process completed normally 257 PATHNAME created 331 User name okay Password required 332 Login account re...

Страница 138: ...SYSTEM MENU 1 Wireless parameter menu RF MENU 1 Select 1 WLAN in the DEVICE MENU and then press the ENT key The RF MENU screen on the right is displayed 1 PARAMETER Sets up the wireless parameter 2 S...

Страница 139: ...menu and then press the ENT key The SET RF NETWORK screen on the right is displayed 1 NETWORK PARAMETER Sets up wireless network parameter 2 RF OPTION Sets up wireless network option Refer to the foll...

Страница 140: ...ss the BS C key To delete the entire entry press and hold the BS C key or press the SF key and BS C key simultaneously 4 Enter the Service Set ID and press the ENT key The entered Service Set ID is se...

Страница 141: ...y to return to the SET RF PARAMETER screen Wireless Security Mode Settings 1 Select 1 SECURITY MODE in the SET SECURITY menu and then press the ENT key The screen on the right is displayed The highlig...

Страница 142: ...en on the right is displayed 1 WEP OPTION WEP option settings 2 WEP KEY1 WEP KEY 1 settings 3 WEP KEY2 WEP KEY 2 settings 4 WEP KEY3 WEP KEY 3 settings 5 WEP KEY4 WEP KEY 4 settings 6 TRANSMIT KEY TRA...

Страница 143: ...tion key 6 Use the cursor keys or numerical key 2 to highlight 2 KEY and then press the ENT key The mode changes to entry mode and the cursor displays 7 Use the numerical keys to enter an encryption k...

Страница 144: ...tion key Incorrect Encryption Key Examples The encryption key length is incorrect Characters other than hexadecimal notation 0 1 2 3 4 5 6 7 8 9 A B C D E F are used Repeat the above procedure to set...

Страница 145: ...en press the ENT key The screen on the right displays 1 EAP TYPE Selects PEAP or EAP TLS 2 IDENTITY ID 3 ANONYMOUS ID Anonymous ID 4 PASSWORD Password 5 ROOT CERT Root certificate 6 CLIENT CERT Client...

Страница 146: ...aneously 8 Use the cursor keys or numerical key 4 to highlight 4 PASSWORD and then press the ENT key The mode changes to entry mode and the cursor displays 9 Use the numerical keys to enter a password...

Страница 147: ...to highlight 1 AUTH PARAM EAP and then press the ENT key The screen on the right displays 1 EAP TYPE Selects PEAP or EAP TLS 2 IDENTITY ID 3 ANONYMOUS ID Anonymous ID 4 PASSWORD Password 5 ROOT CERT...

Страница 148: ...aneously 8 Use the cursor keys or numerical key 4 to highlight 4 PASSWORD and then press the ENT key The mode changes to entry mode and the cursor displays 9 Use the numerical keys to enter a password...

Страница 149: ...TY CONFIG menu Wireless Security WPA PSK Mode PSK authentication and an encryption system can be used with wireless security WPA PSK mode 1 Select 2 CONFIGURATION at the SET SECURITY menu and then pre...

Страница 150: ...nu 6 Use the cursor keys or numerical key 2 to highlight 2 WPA CIPHER and then press the ENT key The screen on the right displays 1 CIPHER MODE Selects TKIP or AES 7 Ensure that 1 CIPHER MODE is highl...

Страница 151: ...ode changes to entry mode and the cursor displays 5 Use the numerical keys to enter an ID and press the ENT key Press the SF and the BS C key to change the entry mode numerical entry no guidance displ...

Страница 152: ...key The screen on the right displays Use the cursor keys to select a file name A NO FILE EXISTS message displays if no files exist 11 Use the cursor keys or numerical key 6 to highlight 6 CLIENT CERT...

Страница 153: ...Ensure that 1 PRE SHARED KEY is highlighted and then press the ENT key The mode changes to entry mode and the cursor displays 4 Use the numerical keys to enter a shared key and press the ENT key Press...

Страница 154: ...can be used when the mode is set to other than 1 None at the SET SECURITY MODE menu 1 Press the SF key and dot key at the SECURITY CONFIG menu The screen on the right displays 1 EAP START EAP authenti...

Страница 155: ...trength of received packets LINK QUALITY Displays the overall communication quality with the access point Display Communication Status EXCELLENT Excellent communication link GOOD FAIR POOR Poor commun...

Страница 156: ...ing sections for each of the above menus Press the Backspace clear key to return to the DEVICE MENU Viewing Bluetooth information 1 Select 2 BLUETOOTH in the DEVICE MENU and then press the ENT 2 Selec...

Страница 157: ...current setting is displayed 1 DEVICE NAME Sets up the Bluetooth device name Press the Backspace clear key to return to the SET BLUETOOTH menu 2 Press the ENT key Entry mode is activated and the curso...

Страница 158: ...eys or numeric keys 1 2 to select the menu and then press the ENT key Entry mode is activated and the cursor is displayed 3 Use the numeric keys to enter the desired value INQUIRY TIME Valid Range 0 2...

Страница 159: ...splayed To set up the 4 SECURITY use the cursor keys to highlight and set the desired setting 3 Use the numeric and period keys to enter the desired value PEER BD ADDR 12 digit hexadecimal numbers onl...

Страница 160: ...characters can be entered There is no default setting To switch the entry mode between numeric and alphabet entries press the SF key To delete a single character press the Backspace clear key To dele...

Страница 161: ...cursor is displayed To set up the 3 SECURITY use the cursor keys to highlight and set the desired setting 3 Use the numeric and period keys to enter the desired value PASSKEY Up to 16 characters TIME...

Страница 162: ...up the timeout period in seconds for the data link establishment 4 FIELD SPACE Ignore Ignores the trailing spaces in data fields Data Treats the trailing spaces as data When changing the setting 1 Use...

Страница 163: ...detection 2 INQUIRY TIME Sets up the device inquiry time 3 NUM RESPONSES Sets up the number of devices to detect Press the Backspace clear key to return to the BROWSE DEVICE menu 2 Use the cursor keys...

Страница 164: ...hold the Backspace clear key or press the SF and Backspace clear keys simultaneously 7 Press the ENT key 8 Use the cursor keys or numeric key 1 to highlight the 1 DO IT and then press the ENT key The...

Страница 165: ...a remote device address select 1 Yes and press the ENT key To cancel the new setting select the 2 No and press the ENT key The screen returns to the BROWSE DEVICE menu If the detected device does not...

Страница 166: ...y time to search services The service inquiry time is used only for the service search 1 DO IT menu Valid Range 1 255 Default 30 seconds Note that the setting specified here will not be saved To delet...

Страница 167: ...he right Press the Backspace clear key to return to the BROWSE DEVICE menu If the service inquiry fails the screen on the right will be displayed Check the following and retry the service inquiry The...

Страница 168: ...the authorized remote device address use the cursor keys or numeric keys to select the desired address and then press the ENT key The screen on the right is displayed To delete the selected address se...

Страница 169: ...connection mode The connection mode is used only for transferring files 1 DO IT menu Note that the setting specified here will not be saved 4 Use the cursor keys or numeric key 3 to highlight the 3 T...

Страница 170: ...en press the Enter key Press the Backspace clear key to return to the SERIAL PORT MENU Point The protocols Ymodem protocol BHT protocol or BHT Ir protocol used for the file transfer are in accordance...

Страница 171: ...rsor keys to highlight the program to be deleted 3 Press the ENT key The screen on the right displays To delete files Use the cursor keys or numerical key 1 to highlight 1 Yes and then press the ENT k...

Страница 172: ...ont files that are not used can be deleted When deleting font files upload the font files to the host computer and so on to ensure that they are backed up Refer to section 4 5 4 Uploading Files UPLOAD...

Страница 173: ...d file is deleted and the screen on the right displays Press the BS C key to return to the DELETE FILE menu To cancel Use the cursor keys or numerical key 2 to highlight 2 No and then press the ENT ke...

Страница 174: ...arameter file based on the current setting values and upload it to the host computer and so on After uploading delete the created system parameter file Downloading the System Parameter File Receive th...

Страница 175: ...the right displays indicating the file name and the number of received records the total number of records Press the BS C key to abort the download and return to the SYSTEM PARAMETER menu 3 Upon compl...

Страница 176: ...ight displays indicating the file name and the number of sent records the total number of records Press the BS C key to abort the upload and return to the SYSTEM PARAMETER menu 3 Upon completion of up...

Страница 177: ...The SET REMOTE WAKEUP menu displays as shown on the right 1 REMOTE WAKEUP Enables or disables remote wake up 2 TRANSMIT SPEED Sets the transmission speed for remote wake up Press the BS C key to retu...

Страница 178: ...tem message file from the host computer and so on to which it was backed up and after setting the stored system messages delete the received system message file The communication parameters communicat...

Страница 179: ...to the SYSTEM MESSAGE menu 3 Upon completion of downloading the BHT displays the screen shown on the right and the speaker beeps once Press the BS C key to return to the SYSTEM PARAMETER menu The spe...

Страница 180: ...YSTEM MESSAGE menu 3 Upon completion of uploading the BHT displays the screen shown on the right and the sepaker beeps once Press the BS C key to return to the SYSTEM PARAMETER menu The speaker sounds...

Страница 181: ...efer to section 4 2 1 Updating the BHT System for details 1 Use the cursor keys or numerical key 1 to highlight 1 SYSTEM MODIFY and then press the ENT key The screen on the right displays If the downl...

Страница 182: ...ot key to enter the correct file name Press the SF key to change the entry mode numerical entry no guidance display and alphabet entry To delete a single character press the BS C key To delete the ent...

Страница 183: ...displays upon completion of the update Press the BS C key to return to the CU F W MODIFY menu When the Displayed File Name Differs from the CU 811 System Update File If the name of the file displayed...

Страница 184: ...MODIFY menu If the BHT Has not been Set on the CU 811 when Updating the CU 811 System The screen on the right displays if the BHT has not been set on the CU 811 when updating the CU 811 system Set the...

Страница 185: ...173 5 3 Bluetooth Wireless Communication 175 5 3 1 Usage Precautions 175 5 3 2 Setting Parameters 176 5 4 Basic Communication Specifications and Parameters 177 5 4 1 Basic Communication Specifications...

Страница 186: ...mmunication speed Freedom from regulations and licenses that differ from country to country when using wireless devices Communication is performed by arranging the BHT and other IrDA compliant devices...

Страница 187: ...1 2 BHT Hardware Physical Layer and Communication Protocols BHT Hardware Physical Layer Exclude Transmission Speed 460 8 kbps The BHT complies with IrDA Ver1 3 Low Power physical layer compliant by I...

Страница 188: ...munication fails z If the BHT is introduced into an environment in which a device using the 2 4 GHz frequency band is operating or if another device using the 2 4 GHz frequency band is introduced foll...

Страница 189: ...d on the access point setting Please note that 11g should be selected when 11b 11g auto WEP Wired Equivalent Privacy When WEP is ON messages to be sent received over the wireless LAN will be encrypted...

Страница 190: ...his is the password used for 802 1x authentication This is valid only when the EAP TYPE is PEAP ROOT CERTIFICATE This setting is for the filename of the root certificate used for 802 1x authentication...

Страница 191: ...munication distance between the BHT and other devices used is about 5m Even if the communication distance is within 5m communication may not be possible depending on the other device and the environme...

Страница 192: ...keys for mutual authentication and for establishing secure links between themselves Security Modes This BHT supports the following three security modes 1 No security There is no security authenticatio...

Страница 193: ...p synchronization is an asynchronous system that synchronizes each character as a unit that is it externally adds start and stop bits to the leading and trailing bit positions of the character to be t...

Страница 194: ...the start and stop bits Vertical Parity A vertical parity bit is a redundant bit that is added to every character transmitted in order to check that data has been transmitted accurately The parity bi...

Страница 195: ...only possible when communicating from one BHT 805BWB unit to another or with the CU 821 Note2 4 Mbps is only possible for communication with the dedicated CU 811 unit System Mode Refer to Chapter 4 S...

Страница 196: ...180 BHT 805BWB...

Страница 197: ...Battery Cartridge Replacement Method 182 6 2 Using the BHT after Long Periods 184 6 3 Daily Maintenance 185 6 3 1 Proper Care of the BHT 185 6 3 2 Proper Care of the CU CH 185 Chapter 6 Maintenance T...

Страница 198: ...1 2 Battery Cartridge Replacement Method 1 Press the power key to turn OFF the BHT power The screen on the right displays Point Do not remove the battery cartridge until the power turns OFF and the sc...

Страница 199: ...se read the following items prior to use z Never charge the battery cartridge in the vicinity of fire or under a scorching sun z Always use a dedicated charger to charge the battery cartridge Mishandl...

Страница 200: ...tridge This is used as a memory back up power source and therefore should not be removed from the BHT for at least 10 minutes Does the normal screen display The BHT can be used Charge promptly before...

Страница 201: ...n soapy water always use neutral detergent and wrung out thoroughly Any dirt or dust adhering to the red clear plate of the barcode reading window will adversely affect reading performance When using...

Страница 202: ...186 BHT 805BWB...

Страница 203: ...BHT 805BWB 7 1 System Errors 188 7 2 System Mode Errors 192 Chapter 7 Error Messages This chapter describes causes and countermeasures for error messages that display during BHT use...

Страница 204: ...error has occurred Contact your system administrator If low battery is detected the warning tone beeps three times After that it will resume previous regular operation The battery output level has dr...

Страница 205: ...resume function set and therefore resume info has been lost The application restarts from the beginning If this error occurs frequently contact your system administrator The message continues to displ...

Страница 206: ...ressing 1 Yes runs the code scanning demo Press the trigger switch to start the code scanning demo Selecting 2 No turns the power off If this error occurs the warning tone beeps five times and then tu...

Страница 207: ...tion program loaded Your settings made in System Mode contain an error Contact your system administrator If this error occurs the System Mode settings revert to the factory defaults If this error occu...

Страница 208: ...he memory is insufficient for storing files to be downloaded Press the 2 key to return to the SYSTEM MENU then delete unnecessary files in the memory or decrease the size of the file to be downloaded...

Страница 209: ...ing has failed Uploading has failed To retry downloading uploading press the 1 key To return to the SYSTEM MENU press the 2 key Check the interface port communications parameters and communications pr...

Страница 210: ...eter file or system message file to be uploaded Press the BS C key to return to the SYSTEM MENU and delete unnecessary files The memory already contains 420 files so the BHT system parameter file or s...

Страница 211: ...ecifications 196 8 1 1 Hardware Specifications 196 8 1 2 Barcode Specifications 197 8 1 3 Scanning Performance 198 8 1 4 Interface Specifications 200 Chapter 8 Specifications This chapter describes th...

Страница 212: ...gic keys 4 Function keys 11 Numerical keys etc 12 Display Type Dot matrix TFT liquid crystal display LCD with backlight Formation 240 dots wide by 320 dots high Font size Chars x Lines Dots W x H Full...

Страница 213: ...lack white bar reflection intensity difference 0 8 Min 0 19 mm PCS value 0 45 RSS GS1DataBar RSS 14 GS1 DataBar Omnidirectional RSS 14 Truncated GS1 DataBar Truncated RSS 14 Stacked GS1 DataBar Stacke...

Страница 214: ...5 mm 0 33 mm 1 0 mm 1 2 mm 0 H 75 mm 1 0 H 110 mm 2 0 H 240 mm 3 H 570 mm 4 H 620 mm 5 The label position is on the BHT 805BWB central axis The BHT 805BWB may fail to read codes due to specular reflec...

Страница 215: ...e 500 Lx Xenon arc lamp ITF conforming to the UPC Shipping Container Code Reflection intensity of white bars 85 min Reflection intensity of black bars 5 max 1 0 magnifications PCS value 0 9 min 4 Unde...

Страница 216: ...e for communication with the dedicated CU 811 unit The maximum transmission speed in all other cases is 115 200 bps Wireless Interface IEEE802 11b Communication method DS SS Frequency band 2400 2483 5...

Страница 217: ...equirements CU 801 811 821 202 9 1 3 Interface Specifications 203 9 2 When File Transfer is Not Possible Using the Transfer Utility 205 Chapter 9 Appendices This chapter describes the CU 800 Series op...

Страница 218: ...n 6 5 VA 7 VA 5V 500 mA Dimensions W x L x H 110 x 134 x 81 7 mm Weight 105 g 110 g 100 g Ambient operating temperature 0 to 40 C Ambient operating humidity 20 to 80 with no dew condensation The CU 82...

Страница 219: ...tor uses Dsub 9P Pin No Signal Name Function Signal Direction CU 801 External Device 2 RD Receipt data 3 SD Transmission data 4 ER Data terminal ready 5 SG Signal ground 6 DR Data set ready 7 RS Trans...

Страница 220: ...terface Port RJ45 jack on the CU 811 Pin No Signal Functions 1 TD Send data 2 TD Send data 3 RD Receive data 4 N C No connection 5 N C No connection 6 RD Receive data 7 N C No connection 8 N C No conn...

Страница 221: ...mission speed with the DIP switch on the reverse side of the CU Defect or abnormality with the USB cable between the PC and CU Use a properly functioning USB cable Unstable signal wire due to such rea...

Страница 222: ...possible to download a file with the same name but different field width from the file already existing in the BHT Either delete the existing data file in the BHT or specify the same field format as t...

Страница 223: ...Customer Registration is required to use QBdirect free of charge When using for the first time complete Customer Registration and then refer to the following procedure to use QBdirect Refer to Custome...

Страница 224: ...Barcode Handy Terminal BHT 805BWB User s Manual First Edition July 2011 DENSO WAVE INCORPORATED...

Отзывы: