Denso BHT-604BW Скачать руководство пользователя страница 1

Barcode Handy Terminal

BHT-604BW

User’s Manual

ALP

+

=

%

#

&

$

:

,

*

-

SPACE

Содержание BHT-604BW

Страница 1: ...Barcode Handy Terminal BHT 604BW User s Manual ALP SPACE...

Страница 2: ...recautions to ensure its products do not infringe upon any patents or other intellectual property rights of other s however DENSO WAVE cannot be responsible for any patent or other intellectual proper...

Страница 3: ...led information on each product Download service Offers downloads of repair modules for the latest BHT Series systems or software and sample programs E mail inquiries Product related queries can be se...

Страница 4: ...be performed prior to commencing operation Chapter 3 Basic Operation Describes basic operations performed by the operator and how to make basic changes to settings such as the beeper volume Chapter 4...

Страница 5: ...k The PDF Bookmark function can be used to jump to the Contents page Procedure 1 Click the Bookmark tab 2 Click to search for the desired item 3 Click the item to be read 1 Click the Bookmarks tab 2 C...

Страница 6: ...page by entering words or characters related to the item being searched 1 Click the Search icon Or select Edit Search 2 Enter the word s or character s to be searched for 3 Click Search 1 Click the Se...

Страница 7: ...in the BHT BASIC Compiler CD ROM This manual can also be downloaded from the DENSO WAVE member s Web site QBdirect BHT BASIC 4 0 Transfer Utility User s Guide This is an instruction manual for softwa...

Страница 8: ...hose conditions that could cause serious bodily injury or death if the instructions are not followed correctly Alerts you to those conditions that could cause minor bodily injury or substantial proper...

Страница 9: ...d cause fire Only use the dedicated charger for charging the rechargeable battery cartridge Using a different type of charger could cause battery rupture or leakage of battery fluid and result in a fi...

Страница 10: ...nearest dealer Failure to do so could cause fire or electrical shock Never use the CU for charging anything other than the specified battery cartridges Doing so could cause heat battery rupture or fi...

Страница 11: ...etting them caught in other objects or entangled in rotating machinery Failure to do so could result in accident or injury Never dis assemble Never disassemble or modify the BHT doing so could result...

Страница 12: ...ing its housing resulting in a fire Always use the CU and AC adapter in a well ventilated area Do not place the CU anyplace where it may be subjected to oily smoke or steam e g near a cooking range or...

Страница 13: ...xigibles de la Directiva 1999 5 CE DENSO WAVE INCORPORATED BHT 604BW Wireless LAN NJT 517 1999 5 K Fran ais Par la pr sente DENSO WAVE INCORPORATED d clare que le terminal BHT 604BW est dot d un modul...

Страница 14: ...adavky a v etky pr slu n ustanovenia Smernice 1999 5 ES Suomi T ten DENSO WAVE INCORPORATED vakuuttaa ett t m n tuotteen BHT 604BW sis lt m langaton WLAN moduli tyyppi NJT 517 on direktiivin 1999 5 EY...

Страница 15: ...ibes the BHT system and provides an overall outline of the BHT 1 1 System Configuration 2 1 1 1 Hardware Configuration 2 1 1 2 Software Configuration 5 1 2 Component Names and Functions 8 1 2 1 BHT Fr...

Страница 16: ...mputer CU 600 Series option Communication unit Connection cable option Used to connect the BHT and host computer Wireless LAN access point option Software BHT BASIC 4 0 Development Pack Option and BHT...

Страница 17: ...mercially Available Product Used to connect the host computer and CU 600 Series Select a cable suited to the CU 600 Series interface being used Supported CU 600 Series Cables CU 601 RS 232C cable Opti...

Страница 18: ...4 BHT 604BW BHT BASIC 4 0 Development Pack Option and BHT BASIC 4 0 Transfer Utility Option Refer to Software Configuration on the following page...

Страница 19: ...ution and debugging 2 Software Used for Application BHT BASIC Programmer s Manual for BHT 600 Series This is an instruction manual used to create handy terminal programs with BHT BASIC BHT BASIC 4 0 D...

Страница 20: ...4 0 Transfer Utility that comes bundled with the BHT BASIC 4 0 Development Pack 3 Software Used at the BHT Unit The BHT unit FLASH memory has a system area and user area with the system program store...

Страница 21: ...not need to display Kanji characters you may delete these JIS font files After deletion the memory area which was occupied by these files can be used as a user area For the deleting procedure refer t...

Страница 22: ...s on how to operate the SYSTEM MENU 5 IrDA interface port Used to exchange data programs with the communication unit CU 600 or other BHTs 6 Hand strap Wear this strap around your wrist to prevent you...

Страница 23: ...key M3 5 Magic key M4 6 Magic key M5 7 Magic key M6 Each of the M3 and M4 keys is assigned a trigger switch by default The M5 key is assigned the C key by default The M6 key is assigned the ENT key by...

Страница 24: ...xecute operations 10 Function keys Used to select functions 11 Power key Turns ON or OFF 12 Backspace key Removes the last character that you entered 13 Clear key Cancels entry and returns the LCD dis...

Страница 25: ...et entry mode at the user program the entry mode changes from numeric entry to alphabet entry and displays Alphabet entry is used when performing FTP settings Refer to Chapter 7 2 1 Numeric Alphabet E...

Страница 26: ...12 BHT 604BW...

Страница 27: ...ding and Charging the Battery Cartridge 14 2 2 1 Battery Power Level Indicator 20 2 3 Attaching the Hand Strap 21 2 3 1 Attaching the Hand Strap 21 2 3 2 Holding the BHT 21 2 4 Initial Setup 22 2 5 Tu...

Страница 28: ...d CH 704 are chargers to separately charge the battery cartridge on its own while the CH 651 and CH 654 are stationary models same type as CU communication unit for directly charging the battery cartr...

Страница 29: ...rminals and indication on the BHT unit and then insert the cartridge in the direction indicated by the arrow Terminal Point Do not use battery cartridges other than those specified by DENSO WAVE 3 Ins...

Страница 30: ...HT from the charger for at least 10 minutes when using the BHT for the first time or when using after long periods of time Red LED ON Green LED ON 6 The BHT indicator LED will change to green when cha...

Страница 31: ...int Charging takes approximately 3 hours An only slightly discharged battery cartridge should take this time to become fully charged Take proper steps if the LED is blinking in red a Detecting the abn...

Страница 32: ...tery cartridges other than those specified by DENSO WAVE 6 Insert the battery cover tab 1 and then close the battery cover 2 The battery cover is now locked in position Note The BHT is equipped with a...

Страница 33: ...ation blowout or combustion Please read the following item prior to use Terminate charging if not completed even after the specified time has elapsed Note The BHT is equipped with a back up battery us...

Страница 34: ...the Enter key The Battery Voltage screen displays while the keys are pressed About the Battery Level The battery power level indicator does not accurately reflect the battery residual power and shoul...

Страница 35: ...Wear the hand strap to prevent the BHT from being accidentally dropped during use 2 3 1 Attaching the Hand Strap Attach the hand strap to the BHT as shown below 2 3 2 Holding the BHT Wear the hand st...

Страница 36: ...c keys Ex September 4 2010 14 20 Point Enter the last two digits for the year and enter the time in 24 hour clock format 3 Press the ENT key to set the date and time The screen right displays when the...

Страница 37: ...the power is next turned ON there are times when a message 2XXX displays asking the user to contact the administrator 2 5 2 Turning the Power OFF after Data Back up 1 Hold down the Power key for at l...

Страница 38: ...ly shut down refers to 2 5 Turning OFF the Power 1 The right message will appear when you insert a charged battery cartridge and turn the BHT on 2 Press the 2 key while holding down the SF key The scr...

Страница 39: ...enabled the screen given right may appear The BHT displays the screen for three seconds and then automatically runs the execution program from the beginning The screen may also appear when the calenda...

Страница 40: ...ered 1000 to 1200 is lost Ex SAMPLE1 DAT 01000 01050 If more than one sequence of records is broken in a same file they will be written into the subsequent records in the BRKLST SYS SAMPLE1 DAT 01200...

Страница 41: ...tem selection using the BHT basic changes to settings and BHT data transmission 3 1 Reading Barcodes 28 3 2 Numeric Data Entry 30 3 3 Task Selection 30 3 4 Changing the Default Settings 31 3 4 1 Proce...

Страница 42: ...ead the barcode successfully the indicator LED will illuminate in blue Blue LED ON Point The barcode reading method may differ depending on the application Select the most appropriate option in accord...

Страница 43: ...The barcode may not be read if surface is extremely curved Read the barcode at the center of the barcode reading window Barcode surface dirt The barcode may not be read if its surface is dirty Wipe th...

Страница 44: ...keys 1 2 and 0 followed by the Enter key 3 3 Task Selection If a selection item such as 1 XXX 2 XXX with numeric values displays enter the values with the numeric entry keys and then press the Enter k...

Страница 45: ...hat notifies the user when barcode reading is complete ON OFF BRIGHTNESS Used to set the backlight brightness of the LCD screen The brightness can be adjusted in 5 levels Levels 1 to 5 BRIGHTNESS PS U...

Страница 46: ...or end of the item highlighted press or to change to the next screen The selected item is highlighted key key 3 Use the and cursor keys to select the setting 4 Press any of the following keys to exit...

Страница 47: ...ontacted for details of operation Request Data gathered by the BHT should be promptly uploaded to the host computer Wireless communication Infrared communication Connector communication IrDA communica...

Страница 48: ...ated interface cable Requests Do not use a cable other than the dedicated interface cable Avoid disconnecting and reconnecting the cable more than once a day Disconnecting and reconnecting the cable t...

Страница 49: ...exposed to light interference from sources such as intence ambient lighting inverter driven fluorescent lighting in particular or direct sunlight This may result in comunication failure When performin...

Страница 50: ...improve communication performance Communication may not be possible at the following locations 1 In the vicinity of devices operating on the same 2 4 GHz waveband as the BHT such as microwave ovens in...

Страница 51: ...4 Executing by Wake up 46 4 3 5 Executing by Remote Wake up 46 4 4 System Mode 47 4 4 1 Starting Up System Mode 47 4 4 2 System Mode Basic Operation 48 4 4 3 SYSTEM MENU Configuration 50 4 5 SYSTEM ME...

Страница 52: ...ssage displays on the screen when the BHT is turned on Point By initializing the system all files in the user area are deleted and therefore all files that need to be backed up should be uploaded to t...

Страница 53: ...Memory Area Selected for Initialization 2 To delete font files Press the 2 key while holding down the SF key The screen displays as shown on the right Next press the 2 key select 2 WHOLE USER AREA and...

Страница 54: ...font files from deletion When the screen displays as shown on the right select the item and press the ENT key Press the C key to return to the screen to select the area for initialization 1 Yes The sy...

Страница 55: ...administrator Note the error number XXXX message displays even although initialization has been completed initialize the BHT again Following initialization all programs and data files stored in the t...

Страница 56: ...http www qbdirect net BHT System Update Refer to section 4 5 15 Updating the System MODIFY MENU and update the BHT system Important In order to prevent the battery running low during the system updat...

Страница 57: ...llowing Web site http www denso wave com en CU 611 System Update Refer to section 4 5 15 Updating the System MODIFY MENU and update the CU 611 system The CU 611 LED flashes during CU 611 system update...

Страница 58: ...on If no program has been selected at the SYSTEM MENU EXECUTE PROGRAM menu and the BHT power is turned ON control will switch to the directory management program and the first of the programs PD4 regi...

Страница 59: ...ersion In the above case the registration order does not change and therefore MAIN PD4 starts up by pressing the Power key AAAAAAAA DAT BBBBBBBB DAT MAIN PD4 Directory info SUBMAIN PD4 MAIN PD4 Upgrad...

Страница 60: ...gram executed If an auto start execution program has been selected at the System Mode 4 5 5 1 Setting the auto start execution program the selected program will be executed If no auto start execution...

Страница 61: ...te wake up setting System message file download upload System update Refer to each item at the 4 5 SYSTEM MENU for details of the above operations 4 4 1 Starting Up System Mode Use the following proce...

Страница 62: ...l be highlighted EXECUTE PROGRAM will be highlighted when System Mode is started up 2 Press the ENT key The selected item is set and the next screen displays Press the C key to return to the previous...

Страница 63: ...o select setting values 1 Press the numerical key corresponding to the item to be selected Alternatively press the cursor keys to select the item The selected item will be highlighted 2 Select the set...

Страница 64: ...Select the item with the numerical keys or cursor keys and press the ENT key SYSTEM MENU 1 and ENT keys 2 and ENT keys 3 and ENT keys C key Exeucting Programs Refer to section 4 5 1 Executing User Pr...

Страница 65: ...d ENT keys 8 and ENT keys 5 and ENT keys 4 and ENT keys C key Refer to section 4 5 6 BHT Operation Test System Information Display Refer to section 4 5 7 System Information Display Downloading Uploadi...

Страница 66: ...SYSTEM MENU 0 with SF held down 2 with SF held down Deleting Program Data Files Refer to section 4 5 10 Deleting Program Data Files C key Deleting Font Files Refer to section 4 5 11 Deleting Font File...

Страница 67: ...Setting Remote Wake up C key 4 with SF held down Downloading Uploading the System Message File Refer to section 4 5 14 Downloading Uploading System the Message File 6 with SF held down Updating the S...

Страница 68: ...key to return to the SYSTEM MENU 2 Use the cursor keys to select the target program The selected program will be highlighted Use the key to scroll down when more than 18 programs have been downloaded...

Страница 69: ...d order Refer to 4 3 Executing User Programs for details Use the following procedure to download files 1 Select 2 DOWNLOAD at the SYSTEM MENU and then press the ENT key The screen displays as shown on...

Страница 70: ...ng the BHT BASIC 4 0 Transfer Utility or similar program the screen displays as shown on the right and file downloading is commenced Refer to the BHT BASIC 4 0 Transfer Utility User s Guide 4 The scre...

Страница 71: ...received file size equals the total file size Press the C key to return to the DOWNLOAD menu With this screen is displayed on the BHT downloading another new file from the host computer allows the BHT...

Страница 72: ...protocol type Communication protocol type Ymodem BHT Ir BHTp Ymodem protocol BHT Ir protocol BHT protocol Interface used Opt Con Infrared interface Connector interface Transmit speed 300 to 460800 Tra...

Страница 73: ...The screen displays as shown on the right if no files that can be uploaded exist in the user area Press the C key to return to the UPLOAD menu 3 The screen displays as shown on the right indicating t...

Страница 74: ...col the sent file size the total file size units KB displays Press the C key to abort the download process and return to the UPLOAD menu 6 When uploading is complete the beeper sounds once and the scr...

Страница 75: ...cation ensure that the BHT infrared communication ports are facing one another When using the connector interface open the BHT connector covers and connect both BHT units using a cable with JC 25 P 3...

Страница 76: ...er of digits to be read for Codabar NW 7 Interface port to be used in user programs Interface port to be used in System Mode Communication parameters for the infrared interface Communication parameter...

Страница 77: ...etries for link release command to be sent Link release command intervals Link release period Service Set ID SSID Not possible to copy correctly if there is a space at the end Power save mode for wire...

Страница 78: ...ATE TIME Sets the calendar clock date and time 4 BARCODE Sets the barcode reading conditions black white inverted label reading function and decode label and minimum number of scan digits for scan cod...

Страница 79: ...en displays as shown on the right The highlighted program will be the program currently set as the auto start execution program 2 Use the cursor keys to highlight the target program 3 Press the ENT ke...

Страница 80: ...STEM menu 1 MESSAGE Sets whether messages displayed at the screen are displayed in English or Japanese The default is the message version selected at the system initializing process The English and Ja...

Страница 81: ...s compatible mode for screen display between the BHT 100 and BHT 7500 This allows BHT 100 Series and BHT 7500 Series application programs to be used at the BHT 604BW without changing or correcting the...

Страница 82: ...th the BHT Communication link with the CU 611 Displays cyclically when the BHT receives no response from the CU 611 or when it is waiting for the link to be established with or severed from the CU 611...

Страница 83: ...bel reading ON Enables black white inverted label reading OFF Disables black white inverted label reading Point By enabling black white inverted label reading it will also be possible to scan black wh...

Страница 84: ...ossibility of such errors 5 Setting the communication environment The communication environment settings following system initialization are follows Do not change these settings unless necessary Item...

Страница 85: ...ollowing section for details of the above items Press the C key to return to the SYSTEM MENU 1 OPTICAL Infrared communication parameters 1 Select 1 OPTICAL at the SET COMMUNICATION menu and then press...

Страница 86: ...eout length in seconds to be applied when a link is to be established 4 FIELD SPACE Specifies handling for trailing spaces in fields To trim trailing spaces in fields select Ignore and to retain them...

Страница 87: ...he right The highlighted settings will be the current settings 1 TRANSMIT SPEED Sets the transmission speed 2 PARITY BIT Sets the vertical parity none odd or even 3 DATA BIT Sets the character length...

Страница 88: ...th in seconds to be applied when a link is to be established 4 FIELD SPACE Specifies the handling for trailing spaces in fields To trim trailing spaces in fields select Ignore and to retain them as da...

Страница 89: ...r programs written in BHT BASIC OPEN COM Optical Uses infrared communication Connector Uses connector communication 2 SYSTEM MODE Selects the infrared communication Optical or connector communication...

Страница 90: ...FILE statement in BHT BASIC 2 BHT Protocol Selects the BHT protocol when uploading downloading in System Mode or for the execution of the XFILE statement in BHT BASIC 3 BHT Ir Protocol Selects the BHT...

Страница 91: ...M transfer None should normally be selected To add the BHT ID number to the transfer tool select Add This setting is not supported Changing this setting has no result 4 INTERVAL Specifies the retry in...

Страница 92: ...s no need to edit the current setting press the ENT key only Point ID numbers should consist of a five digit decimal character string The entry range is from 00001 to 65534 If the entry value is less...

Страница 93: ...er switch key definition screen 6 M5 KEY Displays the M5 key definition screen 7 M6 KEY Displays the M6 key definition screen Refer to the following section for details of the above items Press the C...

Страница 94: ...will return to the SET KEY menu Magic keys M1 to M6 Magic keys M1 to M6 can be set to function as the trigger switch SF key ENT key backlight function ON OFF key MENU key or C key If the M1 key is def...

Страница 95: ...sume function Note The resume function is used to return the BHT status screen when the power is turned ON to the status at the point the power was turned OFF 8 Defragmenting the drive Use the followi...

Страница 96: ...lowing section for details of the above items Press the C key to return to the SET SYSTEM menu 1 SET TCP IP Setting the TCP IP 1 Select 1 SET TCP IP at the SET TCP IP menu and then press the ENT key T...

Страница 97: ...e ENT key If the IP address subnet mask and default gateway are all set to 0 0 0 0 DHCP is enabled Press the C key to return to the SET TCP IP menu 3 TIMEOUT Setting the timeout only when COM1 selecte...

Страница 98: ...PASSWORD Sets the password 4 DEFAULT DIR Specifies an initial directory through which the FTP server will search for files for transfer first when the FTP client establishes a connection to the serve...

Страница 99: ...ed files will be written over the existing files Append Uploaded files will be appended to the existing files 5 VERBOSE MODE Specifies the command response display when using FTP ON Displays a message...

Страница 100: ...gateway is set to a value other than 0 0 0 0 the DHCP does not display on the screen shown on the right C key SF key key 1 TIMEOUT Sets the timeout for acquiring the IP configuration from the DHCP ser...

Страница 101: ...M read write test 3 BEEPER Selects the beeper scale test 4 AGING Selects the aging test 5 LCD Selects the LCD and indicator LED tests 6 FILE Selects the file checksum test 7 COMMUNICATION Selects the...

Страница 102: ...ode type 3 The scanned barcode type number of digits and data display at the screen Ensure that the barcode data and screen display match Press the C key to return to the TEST menu Barcode Type and Co...

Страница 103: ...barcode reading test options to be set Details of option settings are as follows 1 Add on ON OFF The highlighted settings will be the current settings 1 Add on Enables disables add ons 1 Enabling dis...

Страница 104: ...XXX Tested RAM capacity unit kilobytes YYYYY Total RAM capacity unit kilobytes If any error is detected the BHT beeps three times displays a message similar to that shown on the right and aborts the t...

Страница 105: ...n the BHT OFF Scale Frequency Hz do 523 1046 2093 4186 re 587 1174 2349 mi 659 1318 2637 fa 698 1396 2793 sol 783 1567 3135 la 880 1760 3520 ti 987 1975 3951 4 Aging test Use the following procedure t...

Страница 106: ...e right The indicator LED is OFF at this time Press the C key to return to the TEST menu 2 Press the ENT key The entire screen turns black and the indicator LED illuminates in green Press the BS key t...

Страница 107: ...s the C key to return to the TEST menu 5 Press the ENT key The entire screen turns an even lighter shade of gray Press the BS key to return to the previous screen Press the C key to return to the TEST...

Страница 108: ...EST menu 8 Press the ENT key The entire screen turns green and at the same time the indicator LED turns green Press the BS key to return to the previous screen Press the C key to return to the TEST me...

Страница 109: ...he ENT key A 1 dot thick frame displays around the screen Press the BS key to return to the previous screen Press the C key to return to the TEST menu 11 Press the ENT key The beeper sounds once and t...

Страница 110: ...the and SIZE bbbbb Used memory size FREE yyyyy Available memory size 2 Use the cursor keys to highlight a file If there are more than ten files the screen can be scrolled 3 Press the ENT key The file...

Страница 111: ...of the above items Press the C key to return to the TEST menu Infrared Communication Test 1 Arrange two BHTs one as a master station and the other as a slave station to be tested with their IrDA inter...

Страница 112: ...to the TEST COMMUNICATION menu The master BHT automatically returns to the TEST COMMUNICATION At the slave BHT to be tested select 1 SLAVE and at BHT select 2 MASTER Then press the ENT key The screen...

Страница 113: ...s in parentheses are as follows m the sent data 2 A timeout has occurred during standby for data e C key to return to the TEST COMMUNICATION menu pon normal completion of the test the BHT beeps once a...

Страница 114: ...ht and the BHT w Pressing individual keys displays the identifier letters in the positions pre assigned to those keys on th activating the vibrator As long as the individual key is held down the conti...

Страница 115: ...be entered o change the number of echo requests displayed enter the desired value C key to delete all entries made 2 Press the EN ey W n the PIN est sta ning message n display show on the right Press...

Страница 116: ...e PING test Displays the BHT IP address during the PING test only IP Messages displayed during PING test display Waiting Setting up the PING test Opening device Opening devices Routing TCP IP Connecti...

Страница 117: ...tings are displayed 1 DESTINATION IP Specifies the IP address of the host computer to be pinged E S the data size of the echo request 4 TIMEOUT Specifies the timeout period in units of 100 ms fo COUNT...

Страница 118: ...equired TYPE1 INTERVAL and then sends an echo and TIMEOUT should be request again For TYPE 1 the INTERVAL TYPE2 er sending an echo request PING waits for an echo reply llowing that PING waits for the...

Страница 119: ...ect 3 SET DEVICE at the TEST PING menu and then press the ress the C key to return to the TEST PI 3 SET DEVICE PING Device Setting Screen S ENT key The TCP IP communication device link layer and trans...

Страница 120: ...the C key to return to the SYSTEM MENU License List Press the F1 key at the LICENCE INFORMATION screen to display a license list as shown on the right The license list displays the names of functions...

Страница 121: ...right 2 ENT key to display the cursor allowing the product key to e tere En Authorized displays license registration is complete If Reen The y can be acquired when purchasing the product 3 screen sim...

Страница 122: ...on the right 3 Pr Th sc as shown on the right SS MAC address displays as shown on the right Press the C key to return to the SYSTEM INFORMATION screen e ENT key e SYSTEM INFORMATION screen dis ess th...

Страница 123: ...then press the ENT he screen displays as shown on the right ry and or file name FIELDS Specifies field information for data files message indicating the status displays at the bottom of the screen sc...

Страница 124: ...T key P D The FTP client will interpret a character string entered into this box as a directory therefore send a Change Directory request to the FTP server If the specified directory exists in the FTP...

Страница 125: ...When 2 SELECT FILE is Selected The screen displays as shown on the right Use the cursor keys to highlight the upload file and then press the ENT key Return to the previous screen to display the select...

Страница 126: ...ox into this box as a directory rver If the specified efault to the specified one if a Download request the DIR FILE entry box the name at first and ctory exists in the FTP server the server will chan...

Страница 127: ...pload failed Uploading has ended abnormally pload finished Uploading has ended normally of the screen Aborted Uploading or downloadin C D Downloading Downloading starts Download failed Downloading ha...

Страница 128: ...553 Requested action not taken The messages that FTP servers send during and after FTP operations vary but servers all use the same reply codes as listed belo 110 R re ly 120 Service re a prox nnn mi...

Страница 129: ...ER screen Wireless Communcation Settings RF MENU Use the following procedure lect 8 RF at the SYSTE e RF MENU screen displays as shown on the right PARAMETER Pe SITE SURVEY Performs site survey settin...

Страница 130: ...K PARAMETER at the SET RF NETWOR The screen displays as shown on the right 1 Refer to Chapter 5 ommunication 5 3 Wireles details on the Se vi Set ID Ensure that 1 SSID is highlighted and press the ENT...

Страница 131: ...creen ireless Security Mode Settings 1 key t mode WPA2 PSK WPA2 PSK mode To change the settings use the cursor keys or numerical keys 1 2 3 4 5 6 to 3 the SET SECURITY menu 2 Refer to the following se...

Страница 132: ...TICATE Selects open system settings or shared key The highlighted setting is the current setting 3 ress the ENT key or C key to return to the SET RF PARAMETER menu To enable WEP WEP and WEP KEY settin...

Страница 133: ...or numerical keys 2 highlight a WEP KEY from 1 to 4 and then press the ENT key The screen displays as shown on the right 1 KEY SIZE The highlighted setting is the current setting When no encryption ke...

Страница 134: ...correct Encryption Key Examples he encryption key length is incorrect ired number of encryption keys 9 to highlight 6 TRANSMIT KEY and then press the ENT key 10 Reset with T Characters other than hexa...

Страница 135: ...cted a root certificate is used If EAP TLS is selected a root certificate and client certificate are used 4 Use the cursor keys or numerical key 2 to highlight 2 ID The mode changes to entry mode and...

Страница 136: ...OT CERT displays Use the cursor keys to select a file name A NO FILE EXISTS message displays if no files exist 12 Press the C key to return to the SET RF PARAMETER menu Press the SF and the BS key to...

Страница 137: ...W Select 2 CONFIGURATION at the SET SECURITY menu and then press the ENT key The screen displays as shown on the right 2 WPA CIPHER Encryption system setting Press the C key to return to the SET SECU...

Страница 138: ...XISTS message displays if no files exist 12 Press the C key to return to the SET RF PARAMETER menu Press the SF and the BS key to change the entry mode numerical entry alphabet entry no guidance displ...

Страница 139: ...eturn to the SET SECURITY menu 2 1 to highlight 1 e screen displays as shown on the right 13 Use the cursor keys or numerical key 2 to highligh The screen displa 1 CIPHER MODE Selects TKIP or AES 14 E...

Страница 140: ...m can be used with wireless security W ITY menu and he screen on the right displays AUTH PARAM EAP EAP authentication parameter setting WPA CIPHER Encryption system setting ress the C key to return to...

Страница 141: ...e entry mode numerical entry no guidance display and lphabet entry o delete a single character press the BS key 6 Use the cursor keys or numerical key 3 to highlight 3 ANONYMOUS ID and then mode and t...

Страница 142: ...u Use the numerical keys to enter a password and pre Press the SF and the BS key to cha alphabet entry To delete a single character press the Press the C key to d ete all entries mad T Use the cursor...

Страница 143: ...PSK PSK authentication parameter setting 2 WPA CIPHER Encryption system setting Press the C key to return to the SET SECURITY 2 Use the cursor keys or numerical key 1 to highlight 1 AUTH PARAM PSK and...

Страница 144: ...ingle character press the BS key Press the C key to delete all entries made 4 rn to the the SET RF PARAMETER menu Press the ENT key or C key to return to the SET RF PARAMETER menu Wireless Parameter I...

Страница 145: ...interface for the associated access point SIGNAL STRENGTH LINK QUALITY Displays the overall communication qualit Display Communication Status EXCELLENT Excellent communication link GOOD FAIR POOR Poor...

Страница 146: ...the right Press t ey to return to the DELETE FILE menu To can r keys or numerical key 2 to highlight 2 No and th The screen returns to the DELETE FILE menu wn on the right if no files exist ey to retu...

Страница 147: ...EM MENU he DELETE FILE menu screen displays as shown on the right ress the C key to return to the SYSTEM MENU 2 to highlight the font file to be deleted 3 there is insufficient user area by deleting f...

Страница 148: ...and en press the ENT key ress the C key to return to the SYSTEM MENU then press the ENT key The selected file is deleted and the screen displays as shown on the right Press the C key t To cancel Use t...

Страница 149: ...t setting values and upload it to th on After uploading delete the created system parameter file ownloading the System Parameter File eceive the system parameter file from the host computer and so on...

Страница 150: ...PARAMETER menu nds three times if an error occurs during downloading and an Refer to Chapter 7 Error Messages 7 2 System Mode Errors and DOWNLOAD and then press the ENT key The screen displays as sho...

Страница 151: ...screen displays as shown on the right indicating the file name and the number of sent records the total number of records Press the C key to abort the upload and return to the SYSTEM PARAMETER menu 3...

Страница 152: ...M MENU Use the cursor keys or numerical keys 1 2 to highlight the cursor keys and press the ENT Setting the Remote Wake up SET Use the following procedure to perform remote wake up settings Press the...

Страница 153: ...wn in progress Do not remove the battery or Charge the battery gs and upload it to the host ownloading Uploading the System Message File D 1 Upload the system me Download the uploaded system mess Crea...

Страница 154: ...message file the BHT creates a temporary file named _B60MSG FN3 in the user area An error will therefore occur if there is insufficient space in the user area to create the temporary file The created...

Страница 155: ...load and return to the SYSTEM MESSAGE menu 3 Upon completion of uploading the BHT displays the screen shown on the right and beeps once Press the C key to return to the SYSTEM PARAMETER menu The beepe...

Страница 156: ...orrect file name using the procedure on the following page 2 FILENAME ress the C key to return to the SYSTEM PARAMETER menu 2 en press the ENT key he screen shown on the right displays and the BHT sys...

Страница 157: ...e file does not exist when updating the BHT system be used for updating the system enter the correct f 1 Use the cursor keys or numerical key 2 to highlight 2 F the ENT ENAME and then press uidance di...

Страница 158: ...r numerical key 2 to highlight 2 FILENAME and then press the ENT key The mode changes to entry mode and the cursor displays 2 Use the numerical keys and dot key to enter the correct file name Press th...

Страница 159: ...isplays as shown on the right if the CU 611 system update CU 611 System The screen displays as shown on the right if the system updat Download the CU 611 system update file and update the CU 611 syste...

Страница 160: ...146 BHT 604BW...

Страница 161: ...148 5 1 1 Interface Connector and Pin Assignment 148 5 1 2 Interface Cable Connection 149 5 2 Infrared Communication 150 5 2 1 Infrared Communication Port Transmission Speed 151 5 2 2 BHT Hardware Phy...

Страница 162: ...eive data Signal ground Signal Voltage Input Output Level Signal Input Voltage Threshold RD Output Voltage Threshold SD 0 1 3V min 3V max 5V min 5V max Note The BHT connector port is not designed for...

Страница 163: ...Connect the BHT directly to a host computer a modem or a printer with a connector interface cable as illustrated below Ex 1 Cable Connection between BHT and Host computer Ex 2 Cable Connection between...

Страница 164: ...ation speed Freedom from regulations and licenses that differ from country to country when using wireless devices Communication is performed by arranging the BHT and other IrDA compliant devices with...

Страница 165: ...ps CU 611 4Mbps 5 2 2 BHT Hardware Physical Layer and Communication Protocols BHT Hardware Physical Layer Except Transmission Speed 460 8 kbps The BHT complies with IrDA Ver1 3 Low Power physical laye...

Страница 166: ...T is introduced into an environment in which a device using 2 4 GHz waveband electromagnetic waves is operating or if another device using 2 4 GHz waveband electromagnetic waves is introduced followin...

Страница 167: ...d on the access point setting Please note that 11g should be selected when 11b 11g auto WEP Wired Equivalent Privacy When WEP is ON messages to be sent received over the wireless LAN will be encrypted...

Страница 168: ...is is the password used for 802 1x authentication This is valid only when the EAP TYPE is PEAP ROOT CERTIFICATE This setting is for the filename of the root certificate used for 802 1x authentication...

Страница 169: ...nd beginning and end of the character to be transmitted must be defined beforehand Start stop synchronization is an asynchronous system that synchronizes each character as a unit that is it externally...

Страница 170: ...Vertical Parity A vertical parity bit is a redundant bit that is added to every character transmitted in order to check that data has been transmitted accurately The parity bit should be set to either...

Страница 171: ...e for communication with the dedicated CU 611 unit System Mode Refer to Chapter 4 System Operation 4 4 3 System Properties BHT BASIC To set the transmission speed character length vertical parity and...

Страница 172: ...158 BHT 604BW...

Страница 173: ...taking care of the BHT and CU CH 6 1 Replacing the Battery Cartridge 160 6 1 1 Battery Cartridge Service Life 160 6 1 2 Battery Cartridge Replacement Method 160 6 2 Using the BHT after Long Periods 1...

Страница 174: ...e Replacement Method 1 Press the power key to turn OFF the BHT power The screen displays as shown on the right Point Do not remove the battery cartridge until the power turns OFF itself and the messag...

Страница 175: ...ior to use Never charge the battery cartridge in the vicinity of fire or under a scorching sun Always use a dedicated charger to charge the battery cartridge Mishandling may result in battery cartridg...

Страница 176: ...ot be removed from the BHT for at least 10 minutes Yes Power ON The BHT can be used Charge promptly before the battery becomes fully depleted Does the normal screen display No The Set the current date...

Страница 177: ...oapy water always use neutral detergent and wrung out thoroughly Any dirt or dust adhering to the red clear plate of the barcode reading window will adversely affect reading performance When using in...

Страница 178: ...164 BHT 604BW...

Страница 179: ...s causes and countermeasures for error messages that display during BHT use About error messages during executing application program refer to Appendix A Error Codes and Error Messages of Programmer s...

Страница 180: ...Program error has occurred Contact your system administrator If low battery is detected the BHT beeps three times After that it will resume previous regular operation The battery output level has drop...

Страница 181: ...without the battery cartridge loaded or with discharged battery cartridge loaded so unsaved data was lost Contact your system administrator If this error occurs the BHT beeps five times During execut...

Страница 182: ...r occurs frequently make a note of the displayed code and contact your system administrator The BHT displays this error message and automatically runs the execution program from the point of start up...

Страница 183: ...ause Countermeasure If this error occurs the BHT beeps five times An error has occurred during execution of System Program Unload and reload the battery cartridge then turn the BHT on If this error oc...

Страница 184: ...memory is insufficient for storing files to be downloaded Press the 2 key to return to the SYSTEM MENU then delete unnecessary files in the memory or decrease the size of the file to be downloaded In...

Страница 185: ...ding has failed Uploading has failed To retry downloading uploading press the 1 key To return to the SYSTEM MENU press the 2 key Check the interface port communications parameters and communications p...

Страница 186: ...eter file or system message file to be uploaded Press the C key to return to the SYSTEM MENU and delete unnecessary files The memory has already contained 420 files so the BHT system parameter file or...

Страница 187: ...ications This chapter describes the BHT 604BW specifications 8 1 BHT 604BW Specifications 174 8 1 1 Hardware Specifications 174 8 1 2 Barcode Specifications 175 8 1 3 Scanning Performance 176 8 1 4 In...

Страница 188: ...c keys 6 Function keys 16 Numerical keys etc 12 Display Type Dot matrix TFT liquid crystal display LCD with backlight Formation 240 dots wide by 320 dots high Font size Chars x Lines Dots W x H Full w...

Страница 189: ...0 9 Black white bar reflection intensity difference 0 8 Min 0 19 mm PCS value 0 45 RSS GS1 Databar RSS 14 GS1 DataBar Omnidirectional RSS 14 Truncated GS1 DataBar Truncated RSS 14 Stacked GS1 DataBar...

Страница 190: ...ng Distance and Area Minimum Narrow Bar Width Depth of Field 0 15 mm 0 33 mm 1 0 mm 1 2 mm 40 to 110 mm 1 30 to 230 mm 2 30 to 550 mm 3 30 to 600 mm 4 The label position is on the BHT 604BW central ax...

Страница 191: ...n Reflection intensity of black bars 5 max 1 0 magnification PCS value 0 9 min 3 Under the following conditions Ambient illuminance 500 Lx Xenon arc lamp ITF conforming to the UPC Shipping Container C...

Страница 192: ...it The maximum transmission speed in all other cases is 115 200 bps Connector Interface Synchronization Start stop Transmission speed Max 115 200 bps Signal level Conforms to the RS 232C interface Pin...

Страница 193: ...ons and describes causes and countermeasures when unable to transfer files 9 1 CU 600 Specifications 180 9 1 1 Hardware Specifications 180 9 1 2 Charging Requirements CU 601 611 621 180 9 1 3 Interfac...

Страница 194: ...6 5 VA 7 VA 5V 500 mA Dimensions W x L x H 110 x 134 x 81 7 mm Weight 105 g 110 g 100 g Ambient operating temperature 0 to 40 C Ambient operating humidity 20 to 80 with no dew condensation The CU 621...

Страница 195: ...ctor uses Dsub 9P Pin No Signal Name Function Signal Direction CU 601 External Device 2 RD Receipt data 3 SD Transmission data 4 ER Data terminal ready 5 SG Signal ground 6 DR Data set ready 7 RS Tran...

Страница 196: ...erface Port RJ45 jack on the CU 611 Pin No Signal Functions 1 TD Send data 2 TD Send data 3 RD Receive data 4 N C No connection 5 N C No connection 6 RD Receive data 7 N C No connection 8 N C No conne...

Страница 197: ...ch on the reverse side of the CU Defect or abnormality with the USB cable between the PC and CU Use a properly functioning USB cable Unstable signal wire due to such reasons as a USB cable extension C...

Страница 198: ...t possible to download a file with the same name but different field width from the file already existing in the BHT Either delete the existing data file in the BHT or specify the same field format as...

Страница 199: ...Customer Registration is required to use QBdirect free of charge When using for the first time complete Customer Registration and then refer to the following procedure to use QBdirect Refer to Custom...

Страница 200: ...Barcode Handy Terminal BHT 604BW User s Manual First Edition May 2008 Second Edition September 2008 Third Edition March 2010...

Отзывы: