1. Version Display Mode
1.1. Actions
Version information is displayed when the device is started in this mode.
1.2. Starting up
While holding down the "
SOURCE DIRECT
" button, press the power button to turn on the power.
Next, rotate the "
INPUT SELECTOR
". The content of the Display in item "
1.3.
" is displayed.
Startup display
PMA-1600
\\
\
: Region (E2=E2, E1C/JP=JP)
1.3. Display Order
q
System Version →
w
USB-DAC (DSP) Version →
e
FPGA (AL32) Version
→
r
Display / LED All Lighting →
t
Protection history display
q
System Version
System:
**.**
・Power LED : Lights Orange
w
USB-DAC (DSP) Version
USB-DAC:
**.**
・Power LED : Lights Red
e
FPGA (AL32) Version
FPGA:
**.**
・Power LED : Lights Green
r
Display / LED All Lighting
¡¡¡¡¡¡¡¡
¡¡¡¡¡¡¡¡
・Power LED : Lights Orange
t
Protection history display
(a) No detected history
NO
PROTECT
・Power LED : Lights Red
(b) Detection of PROT-1
PROT-1
(c) Detection of PROT-2/ M_B_DOWN
PROT-2
(d) Detection of VOLTAGE_PROTECT
PROT-3
(e) Resetting the protection history
・ With the protection history displayed, press
and hold the "
ANALOG MODE
" button for over
5 seconds to clear the protection history.
・ Protection history is not cleared, even when the
set is reset.
2. Auto standby test mode
Sets the auto standby timer to 4 minutes.
2.1. Operations
Press and hold the "
SOURCE DIRECT
" button for over 1 second while in version display mode.
"
AutoStby Test
" is displayed and then this unit enters the same mode as standard mode, except with
an auto standby timer.
AutoStBy
Test
This mode is canceled when the power is turned off.
3. Factory initialization and Display / LED All Lighting
Make sure to initialize this unit after replacing the microcomputer or any peripheral equipment, or the
PCB.
3.1. Operations
1. Press the power button to turn off the power.
2. While holding down the "
ANALOG MODE
" button, press the power button to turn on the power.
3. Display and LED All Lighting.
4. This mode is canceled when the power is turned off.
3.2. Initialization item
No Items
Details
Default
1
Input Source
Information for the last selected input source
CD
2
Dimmer
Brightness setting of the display
100%
3
Source Direct
Setting the source direct
Off
4
Analog Mode
Setting the analog mode
Off
5
Auto Standby
Setting the Auto Standby (On/Off)
E2 : On, E1C/JP : Off
6
Protection
Information for the last detected protection
NO PROTECT
52
Caution in
servicing
Electrical
Mechanical
Repair Information
Updating