6. Selecting the Mode2 for Service-related
Selecting Each Mode.
6.1. Starting up
While the power is on, hold down buttons "
POWER
" and "
ENTER
" for at least 3 seconds.
(1) "
LEGO Log Capture Mode
" is displayed.
6-1. LEGO Log Capture Mode
• Acquires the Network Module log.
• The log is deleted when the Network Module is deleted.
If an error occurs, it is acquired without turning off the power of this unit.
• The log can be copied to a writable USB flash drive.
It can also be sent to a server if this unit is connected to the Internet.
• The log is stored in the root folder of the USB flash drive with the name "
logs-<friendlyname>-
<number>.tar.gz
".
<
friendlyname
> indicates the friendly name and <
number
> indicates the sequence number.
Previous logs on the USB flash drive are not overwritten. The log is encrypted.
6-1.1. Starting up
While the power is on, hold down buttons "
POWER
" and "
ENTER
" for at least 3 seconds.
(1) "
LEGO Log Capture Mode
" is displayed.
6-1.2. If the USB flash drive is connected after starting the unit
(1) The log is written to the USB flash drive and "
Storing Logs...
" is displayed.
Press the "
ENTER
" button to send the log to the server too.
(2) When a log package is saved to a USB flash drive, "
USB SUCCESS
" appears in the display for 5 sec-
onds, regardless of whether the upload to the server was successful.
(3) When saving of the log package fails, "
USB FAILED
" appears in the display for 5 seconds, regardless
of whether the upload to the server was successful.
6-1.3. When the USB flash drive is not connected after startup, and this
unit is connected to the Internet.
(1) The log is sent to the server and the display shows "
Storing Logs...
" for 5 seconds.
(2) When the log package is uploaded, the ticket numbers "
Ticket No:XXXXX
" are displayed until RC
or the "
Enter
" or "
BACK
" button of this machine is pressed.
(3) If the log package upload fails, "
FAILED
" is displayed for 5 seconds.
Before Servicing
This Unit
Electrical
Mechanical
Repair Information
Updating