8
INSTRUCTIONS FOR HANDLING SEMI-CONDUCTORS AND OPTICAL UNIT
Electrostatic breakdown of the semi-conductors or optical pickup may occur due to a potential difference caused by
electrostatic charge during unpacking or repair work.
1. Ground for Human Body
Be sure to wear a grounding band (1 MΩ) that is properly grounded to remove any static electricity that may be
charged on the body.
2. Ground for Workbench
Be sure to place a conductive sheet or copper plate with proper grounding (1 MΩ) on the workbench or other surface,
where the semi-conductors are to be placed. Because the static electricity charge on clothing will not escape through
the body grounding band, be careful to avoid contacting semi-conductors with your clothing
<Incorrect>
CBA
Grounding Band
Conductive Sheet or
Copper Plate
1MΩ
1MΩ
<Correct>
CBA
Содержание CEOL Piccolo DRA-N5
Страница 17: ...17 5 Remove the MAIN BOARD Shooting of photograph D...
Страница 40: ...40 Personal notes...
Страница 62: ...62 PCM9211 AMP IC103...
Страница 63: ...63 PCM9211 Block Diagram...
Страница 64: ...64 PCM9211 Pin Discriptions...
Страница 70: ...70 L6565 SMPS IC821 L6565 Block Diagram...
Страница 71: ...71 ICE3BR1765J SMPS IC871 ICE3BR1765J Block Diagram...
Страница 72: ...72 2 DISPLAY S020 MXS4035A 3 DISPLAY CP661...