JIG FOR SERVICING
Use the following jigs (extension cable kit) when repairing the PCBs.
Order with your dealer for the jigs your dealer if necessary.
CAUTION : Incorrect connections may cause malfunction.
Connection of Jig for DIGITAL PCB
---Items to Be Prepared---
8U-110084S : EXTENSION UNIT KIT
:
1 Set
8U-110136S : EXTENSION UNIT KIT
:
1 Set
Insulation sheet (Not supplied)
:
3 sheet
Ground lead (Not supplied)
:
3 pc
-Proceeding-
(1) Remove the screws.
(2) Remove the connector PCB.
↑
Shooting direction: A
↑
x31
x14
x2
x1
N1018
N1022
N1023
N1040
(3) Remove the DIGITAL PCB from the chassis and turn it over.
Place an insulation sheet larger than the PCB underneath the DIGITAL PCB.
b
Connect the earth of the PCB to the chassis using an earth wire, etc.
N5000
x1
CN4203
CN4202
CN4204
CN4201
CN4200
from AMP PCB
PCB DIGITAL
PCB VIDEO
PCB INPUT
Insulation sheet
CHASSIS-HDMI CONNECTOR