Quick Guide
20/48
21/48
SpillGuard® connect Quick Guide |
276016 |
Rev. 1
3. Product description
3.1. Indicators and operator controls
LED
“Red” LED
The “red” LED illuminates during operation
and when an alarm is triggered
push
Push button
The Push button is used to switch SpillGuard®
connect on and off and also to turn off the
signal when an alarm has been triggered.
Wireless signal
In the event of a leak, the alarm signal is
transmitted as a digital signal by means of
the integrated wireless module. The alarm is
transmitted by radio (narrow band NB-IoT) to
the DENIOS server and from here to the text
message and/or e-mail recipient saved.
3.2. Technical data
Marking
II 1G Ex ia ma IIB T4 Ga
Operational temperature
range*
0 °C to 40 °C
Temperature class
T4 (max. 135°C)
Explosion group
IIB
Ignition protection type
Intrinsically safe
encapsulation
Equipment category
1G
Dimensions
Ø 110 mm, height
40 mm
Weight
215 g
“Red” LED
Push button
Nominal voltage
3.0 V
Duration of use
Max. 5 years
Required level height for
sensor wetting
6 mm
Certificate
TÜV 20 ATEX 8602
IECEx TUR 20.0076
*
Operational temperature range
The recommended operational temperature
range is the basis for the given period of use of
5 years. SpillGuard® connect can also be used
at a temperature of down to maximum -10°C.
A longer load at low or high temperatures or
high humidity can shorten the actual battery
service life. In the case of temperatures
fluctuating around the dew point, false alarms
can occur more often.
3.3. WEB registration using
registration code
Together with the delivery note you will
receive a 12-digit registration code. For initial
registration:
1.
Open your web browser and enter the
following address:
http://connect.denios.com
2.
Enter the 12-digit registration code and
click „Next“.
Registration
NEXT
aKQq-q9kB-fbg3