Product are imported and distributer by VINA STAR JSC.
Hotline: 1900 588 851
11
Under any circumstances, make sure the cooker is well ventilated
and the air inlet and outlet are not
blocked. Ensure the cooker is in good work state. As shown below
Note: The safety distance between the hotplate and the cupboard above
the hotplate should be at least 760mm.
Cut out the work surface according to the sizes shown in the drawing.
For the purpose of installation and use, a minimum of 50mm space
shall be preserved around the hole.
Be sure the thickness of the work surface is at least 30mm. Please
select heat-resistant work surface material to avoid larger deformation
caused by the heat radiation from the hotplate.
Table Top Installation
The cooker hob can be used on the table top of cabinet.The ceramic hob
should be placed horizontally.
A(mm) B(mm)
C(mm)
D
E
760
50 mini 20 mini Air intake Air exit 5mm