Tightening torques [Nm]
DC 1 / 2
DC 5
DC 10
Reeving
1/1
1/1
2/1
Service cover
5,5
7,5
Limit stop
4,0
4,3
Chain anchorage halves
-
-
10,5
Guide plate
5,5
Tab. 58
8.5.5.8
Lubricating the hoist chain
After fitting, before a test load is lifted and before the hoist is put into operation as well as during normal opera‐
tion when no load is attached, the chain link contact areas must be lubricated with gear grease, part no.
665 009 44.
The chain link contact areas must be relubricated appropriately – after being cleaned – at intervals depending on
the service and load conditions. A dry film lubricant should be used in environments where abrasives occur (em‐
ery, sand, etc.). For non-standard lubrication, see
"Available hoist chains", Page 77.
CAUTION
Premature wear of the chain.
Danger of load being dropped due to broken chain.
The chain must be lubricated along its entire length.
Even chain links which are covered, e.g. in the chain anchorage, hook assembly, limit stop or crab frame, must
be fully lubricated.
DC 1-10 chain hoist
Fig. 54
Cut off the tip of the grease tube and insert the grease tube at the lubri‐
cation point. Insert grease into the chain guide by pressing the tube
while you run the chain to its end positions to ensure complete and
even lubrication of the chain.
82
214
80
2 44/291
113
Содержание DC-Com 1
Страница 39: ...214 802 44 291113 39...
Страница 45: ...Fig 21 214 802 44 291113 45...
Страница 46: ...Fig 22 46 214 802 44 291113...
Страница 102: ...214802ET indd 291113 102 12 Spare parts 12 1 Overview 1 1 reeving 2 1 reeving 42764247 eps...
Страница 104: ...214802ET indd 291113 104 12 3 Parts on the gearbox 42763847 eps...
Страница 106: ...214802ET indd 291113 106 12 4 Chain drive 42764346 eps 1 1 reeving 2 1 reeving...