background image

ENTER

Concentration Mode – Rinse Speed

• Adjust rinse pump speed 
• Press ENTER to modify 

setting

• Use UP & DOWN arrows to 

adjust rinse speed

• Press ENTER when desired 

speed is displayed

• Press UP or DOWN arrow to 

advance to other screens

Содержание TITAN II

Страница 1: ...ENTER DEMA Engineering Company Titan II Installation and Programming Training ...

Страница 2: ...e calls Automatically switches to probeless mode if the probe fails to function Can be set up in 3 different modes concentration probeless or auto switchover Optional items include Magnetic field sensor Low level out of product alarm Available for 2 or 3 products Easy to add 3rd pump if necessary ...

Страница 3: ...de Two product liquid liquid or liquid dry Three product all liquid or liquid liquid dry 100 260VAC 50 60Hz main power constant power 24 480VAC trigger signals DEMA solenoid for dry detergent control Rinse pump output 0 5 oz min 16ml min T 812 DL T 813 DLL ...

Страница 4: ...ENTER Wall Mounting Unpack the Titan Remove mounting plate from Titan Attach mounting plate to wall Install Titan on the mounting plate Replace screw Remove screw and slide plate down ...

Страница 5: ...ENTER Wall Mounting Follow instructions on Mounting Bracket ...

Страница 6: ...tan that s convenient for operation and chemical locations Distance from electrical connections for Titan Flat vertical surface away from splashing and steam originating from machine Titan should be installed in an easily observed and serviceable location ...

Страница 7: ...Connection Connect main power and triggers to the dish machine following manufacturers recommendations Constant main power should be supplied at 100 250VAC Connect detergent and rinse triggers to dish machine 24 480VAC ...

Страница 8: ... Trigger HOT RED Rinse Trigger RETURN GREEN Earth Ground WHITE DISH MACHINE ELECTRICAL CONNECTION POINT WARNING For safety purposes disconnect main power to the dish machine Connect power to the Titan per the dish machine manufacturer s recommendations UNIT MUST BE GROUNDED EARTHED ...

Страница 9: ...ad Fitting Install detergent bulkhead fitting to dish machine wash tank Install above the water line in the tank Bulkhead fitting should be directly above concentration Probe Gasket should be installed externally to the wash tank ...

Страница 10: ...ctions From water supply run OD copper tubing to inlet fitting of Titan detergent valve From outlet fitting of Titan detergent valve run OD copper tubing to inlet of Viking bowl vacuum breaker From outlet of Viking bowl run 9 16 ID tubing to bulkhead fitting mounted on side of wash tank ...

Страница 11: ...eck valve for rinse and sanitizer Stainless steel check valve for rinse Kynar plastic check valve for sanitizer Cut the OD vinyl tubing to length required to reach from the rinse sanitizer chemicals to the Titan pumps Cut vinyl tubing to length required to reach from Titan pumps and rinse sanitizer check valves ...

Страница 12: ...e installed on lower half of the wash tank The probe should be installed directly below chemical injection when possible Remove electrical ring connectors from probe and crimp conductors of probe cable Re install ring connectors and secure excess probe cable ...

Страница 13: ...ENTER Typical Titan II Set Up ...

Страница 14: ...utton Functions LEFT arrow moves cursor to the left DOWN arrow decreases value or moves cursor down RIGHT arrow moves cursor to the right UP arrow increases value or moves cursor up ENTER button accepts values entered ...

Страница 15: ...ENTER Titan II Programming Separate sections for auto switchover probeless and concentration mode ...

Страница 16: ...own when unit is not being programmed Press enter to advance to priming and programming functions Unit will return to this screen during programming if long delays are taken during programming Idle screen message can be changed in programming ...

Страница 17: ...age Screen Press ENTER to modify language Use UP DOWN arrows to select between 4 languages English Spanish Portuguese and French Press ENTER to select desired language Press DOWN arrow to advance to other screens ...

Страница 18: ...ENTER Detergent Prime 1st screen seen after the language screen Press enter to start stop pump priming OR Press DOWN arrow to advance to other screens ...

Страница 19: ...ENTER Rinse Prime Press enter to start stop pump priming OR Press DOWN arrow to advance to other screens ...

Страница 20: ...ENTER Sanitizer Prime Press enter to start stop pump priming OR Press DOWN arrow to advance to other screens ...

Страница 21: ...Information Screen DET P Probeless mode C Concentration mode Active feeding Active trigger SP Detergent set point in concentration probe mode Can be used as low level alarm for probeless mode Input Actual probe reading ...

Страница 22: ...ENTER Detergent Information Screen DET Probeless Mode Initial charge Top off recharge Dwell cycle DET Concentration Mode Received trigger adding product Received trigger not adding product ...

Страница 23: ...nt Displays number of rack counts registered Rack counts are generated by rinse length in conveyor mode or machine operations in door mode Can be reset in programming mode Press DOWN arrow to advance to other screens ...

Страница 24: ...cale Allows for a dish machine de scaling process Press enter to disable function of Titan II Detergent and rinse will not respond to trigger signals Press enter to end de scale mode re activate to full function ...

Страница 25: ...ENTER New Program Press enter to begin new program ...

Страница 26: ...o Switchover Mode Allows automatic switching from concentration to probeless and back due to typical probe issues Proper set up of both concentration and probeless is required for Titan II to function correctly ...

Страница 27: ... Mode Press ENTER to modify setting Use UP or DOWN arrows to change between auto switchover concentration and probeless modes Press ENTER when auto switchover is displayed Press UP or DOWN arrow to advance to other screens ...

Страница 28: ...witchover Mode Switchover Alarm Press ENTER to modify setting Use UP or DOWN arrows to change between inactive or active Press ENTER when desired mode is displayed Press UP or DOWN arrow to advance to other screens ...

Страница 29: ...ervice dispenser soon Up to 16 characters per line and 2 lines Press ENTER to modify setting Use LEFT RIGHT arrows to move between characters Message can be modified by moving curser LEFT or RIGHT Press ENTER when desired message is displayed Press UP or DOWN arrow to advance to other screens ...

Страница 30: ...tchover Mode Machine Type Press ENTER to modify setting Use UP or DOWN arrows to change between Conveyor and Door Press ENTER when desired machine type is displayed Press UP or DOWN arrow to advance to other screens ...

Страница 31: ...ode Trigger Mode Press ENTER to modify setting Use UP or DOWN arrows to change between Detergent Rinse Detergent Only or Rinse Only Press ENTER when desired mode is displayed Press UP or DOWN arrow to advance to other screens ...

Страница 32: ...ENTER Auto Switchover Mode Dirty H2O Alarm Press ENTER to set to active or inactive Sounds alarm to notify wash tank water needs to be changed Press UP or DOWN arrow to advance to other screens ...

Страница 33: ...min until alarm sounds Countdown starts with first wash trigger and does not stop or pause Use LEFT RIGHT arrows to move between characters Use UP DOWN arrows to adjust each character Press ENTER when desired name is displayed Press UP or DOWN arrow to advance to other screens ...

Страница 34: ...me Up to 16 characters Press ENTER to modify setting Use LEFT RIGHT arrows to move between characters Use UP DOWN arrows to adjust each character Press ENTER when desired name is displayed Press UP or DOWN arrow to advance to other screens ...

Страница 35: ...r Mode Alarm Volume Sets volume of audible detergent alarm Press ENTER to modify setting Use UP or DOWN arrows to adjust volume Press ENTER when desired volume is reached Press UP or DOWN arrow to advance to other screens ...

Страница 36: ...Point Maintains detergent level with concentration probe Press ENTER to modify setting Use UP DOWN arrows to adjust concentration set point DEMA units Press ENTER when desired setting is displayed Press UP or DOWN arrow to advance to other screens ...

Страница 37: ...ols how quickly set point is reached high feed rate can lead to over shooting Press ENTER to modify setting Use UP DOWN arrows to adjust feed rate Press ENTER when desired setting is displayed Press UP or DOWN arrow to advance to other screens ...

Страница 38: ...Delay Amount of time before detergent alarm sounds Press ENTER to modify setting Use UP DOWN arrows to adjust time setting minutes seconds Press ENTER when desired setting is displayed Press UP or DOWN arrow to advance to other screens ...

Страница 39: ...ed Limit Limits the amount of time that the detergent pump will run without reaching set point Press ENTER to modify setting Use UP DOWN arrows to adjust feed limit in minutes and seconds Press DOWN arrow to advance to alarm delay ...

Страница 40: ...witchover Mode Recharge Time Press ENTER to modify setting Use UP DOWN arrows to adjust time setting minutes seconds Press ENTER when desired setting is displayed Press UP or DOWN arrow to advance to other screens ...

Страница 41: ... Dwell Time For conveyor machine type only Press ENTER to modify setting Use UP DOWN arrows to adjust time setting minutes seconds Press ENTER when desired setting is displayed Press UP or DOWN arrow to advance to other screens ...

Страница 42: ...Dead Cycles For door machine type only Press ENTER to modify setting Use UP DOWN arrows to adjust number of cycles between recharges Press ENTER when desired setting is displayed Press UP or DOWN arrow to advance to other screens ...

Страница 43: ...witchover Mode Initial Charge Press ENTER to modify setting Use UP DOWN arrows to adjust time setting minutes seconds Press ENTER when desired setting is displayed Press UP or DOWN arrow to advance to other screens ...

Страница 44: ...Defines time between trigger signals for an initial charge Press ENTER to modify setting Use UP DOWN arrows to adjust time setting hours minutes Press ENTER when desired setting is displayed Press UP or DOWN arrow to advance to other screens ...

Страница 45: ...itchover Mode Rinse Speed Adjust rinse pump speed Press ENTER to modify setting Use UP DOWN arrows to adjust rinse speed Press ENTER when desired speed is displayed Press UP or DOWN arrow to advance to other screens ...

Страница 46: ... type only Rinse length should match the amount of rinse time per rack Allows Titan II to count racks on a conveyor machine Use UP DOWN arrows to adjust rinse length Press ENTER when desired length is displayed Press UP or DOWN arrow to advance to other screens ...

Страница 47: ...elay For door machine only Adjust delay time to start rinse pump Press ENTER to modify setting Use UP DOWN arrows to adjust rinse delay Press ENTER when desired rinse delay is displayed Press UP or DOWN arrow to advance to other screens ...

Страница 48: ...it For door machine only Sets maximum rinse pump run time Press ENTER to modify setting Use UP DOWN arrows to adjust rinse limit seconds Press ENTER when desired rinse limit is displayed Press UP or DOWN arrow to advance to other screens ...

Страница 49: ...er Mode Sanitizer Speed Adjust sanitizer pump speed Press ENTER to modify setting Use UP DOWN arrows to adjust sanitizer speed Press ENTER when desired speed is displayed Press UP or DOWN arrow to advance to other screens ...

Страница 50: ...r Mode Sanitizer Mode Press ENTER to modify setting Use UP or DOWN arrows to change between Run with Rinse or Run with Detergent Press ENTER when desired mode is displayed Press UP or DOWN arrow to advance to other screens ...

Страница 51: ...word 4 numbers Press ENTER to modify setting Use LEFT RIGHT arrows to move between numbers Use UP DOWN arrows to at adjust each number Press ENTER when desired code is displayed Press LEFT arrow to confirm setting Press UP or DOWN arrow to advance to other screens ...

Страница 52: ...ENTER Auto Switchover Mode End Programming Press enter to exit programming ...

Страница 53: ...ENTER Probeless Mode Programming Start of probeless programming Section for dedicated probeless dispenser set up ...

Страница 54: ...ENTER Probeless Mode Press ENTER to modify setting Use UP or DOWN arrows to change between modes Press ENTER when auto switchover is displayed Press UP or DOWN arrow to advance to other screens ...

Страница 55: ...less Mode Machine Type Press ENTER to modify setting Use UP or DOWN arrows to change between Conveyor and Door Press ENTER when desired machine type is displayed Press UP or DOWN arrow to advance to other screens ...

Страница 56: ... Trigger Mode Press ENTER to modify setting Use UP or DOWN arrows to change between Detergent Rinse Detergent Only or Rinse Only Press ENTER when desired mode is displayed Press UP or DOWN arrow to advance to other screens ...

Страница 57: ...ENTER Probeless Mode Dirty H2O Alarm Press ENTER to set to active or inactive Sounds alarm to notify wash tank water needs to be changed Press UP or DOWN arrow to advance to other screens ...

Страница 58: ...ntil alarm sounds Countdown starts with first wash trigger and does not stop or pause Use LEFT RIGHT arrows to move between characters Use UP DOWN arrows to at adjust each character Press ENTER when desired name is displayed Press UP or DOWN arrow to advance to other screens ...

Страница 59: ... to 16 characters Press ENTER to modify setting Use LEFT RIGHT arrows to move between characters Use UP DOWN arrows to at adjust each character Press ENTER when desired name is displayed Press UP or DOWN arrow to advance to other screens ...

Страница 60: ...ode Alarm Volume Sets volume of audible detergent alarm Press ENTER to modify setting Use UP or DOWN arrows to adjust volume Press ENTER when desired volume is reached Press UP or DOWN arrow to advance to other screens ...

Страница 61: ...beless Mode Recharge Time Press ENTER to modify setting Use UP DOWN arrows to adjust time setting minutes seconds Press ENTER when desired setting is displayed Press UP or DOWN arrow to advance to other screens ...

Страница 62: ...ell Time For conveyor machine type only Press ENTER to modify setting Use UP DOWN arrows to adjust time setting minutes seconds Press ENTER when desired setting is displayed Press UP or DOWN arrow to advance to other screens ...

Страница 63: ...d Cycles For door machine type only Press ENTER to modify setting Use UP DOWN arrows to adjust number of cycles between recharges Press ENTER when desired setting is displayed Press UP or DOWN arrow to advance to other screens ...

Страница 64: ...beless Mode Initial Charge Press ENTER to modify setting Use UP DOWN arrows to adjust time setting minutes seconds Press ENTER when desired setting is displayed Press UP or DOWN arrow to advance to other screens ...

Страница 65: ...ines time between trigger signals for an initial charge Press ENTER to modify setting Use UP DOWN arrows to adjust time setting hours minutes Press ENTER when desired setting is displayed Press UP or DOWN arrow to advance to other screens ...

Страница 66: ...ENTER Probeless Mode Detergent Alarm Press ENTER to set to active or inactive Sounds alarm to notify out of detergent condition Press UP or DOWN arrow to advance to other screens ...

Страница 67: ...ENTER Probeless Mode Detergent Type Use manual when alarm option with probe is used Press ENTER to set to Manual Press UP or DOWN arrow to advance to other screens ...

Страница 68: ...t Alarm set point is a probe reading to alarm a low detergent condition Alarm set point should be approx half the difference between a clean and a properly titrated tank of water EG Clean 125 titrate 375 proper set point 250 Press UP or DOWN arrow to advance to other screens ...

Страница 69: ...eless Mode Rinse Speed Adjust rinse pump speed Press ENTER to modify setting Use UP DOWN arrows to adjust rinse speed Press ENTER when desired speed is displayed Press UP or DOWN arrow to advance to other screens ...

Страница 70: ...y For door machine only Adjust delay time to start rinse pump Press ENTER to modify setting Use UP DOWN arrows to adjust rinse delay Press ENTER when desired rinse delay is displayed Press UP or DOWN arrow to advance to other screens ...

Страница 71: ...eyor mode OR can be used to call for initial charge in door mode Rinse length should match the amount of rinse time per rack Use UP DOWN arrows to adjust rinse length Press ENTER when desired length is displayed Press UP or DOWN arrow to advance to other screens ...

Страница 72: ...For door machine only Sets maximum rinse pump run time Press ENTER to modify setting Use UP DOWN arrows to adjust rinse limit seconds Press ENTER when desired rinse limit is displayed Press UP or DOWN arrow to advance to other screens ...

Страница 73: ...Mode Sanitizer Speed Adjust sanitizer pump speed Press ENTER to modify setting Use UP DOWN arrows to adjust sanitizer speed Press ENTER when desired speed is displayed Press UP or DOWN arrow to advance to other screens ...

Страница 74: ...ode Sanitizer Mode Press ENTER to modify setting Use UP or DOWN arrows to change between Run with Rinse or Run with Detergent Press ENTER when desired mode is displayed Press UP or DOWN arrow to advance to other screens ...

Страница 75: ...d 4 numbers Press ENTER to modify setting Use LEFT RIGHT arrows to move between numbers Use UP DOWN arrows to at adjust each number Press ENTER when desired code is displayed Press LEFT arrow to confirm setting Press UP or DOWN arrow to advance to other screens ...

Страница 76: ...ENTER Probeless Mode End Programming Press enter to exit programming ...

Страница 77: ...ENTER Concentration Mode Programming Start of concentration programming Section for a dedicated concentration probe machine set up ...

Страница 78: ...centration Mode Detergent Control Mode Press ENTER to modify setting Use UP or DOWN arrows to change between modes Press ENTER when auto switchover is displayed Press UP or DOWN arrow to advance to other screens ...

Страница 79: ...ration Mode Machine Type Press ENTER to modify setting Use UP or DOWN arrows to change between Conveyor and Door Press ENTER when desired machine type is displayed Press UP or DOWN arrow to advance to other screens ...

Страница 80: ...de Trigger Mode Press ENTER to modify setting Use UP or DOWN arrows to change between Detergent Rinse Detergent Only or Rinse Only Press ENTER when desired mode is displayed Press UP or DOWN arrow to advance to other screens ...

Страница 81: ...ENTER Concentration Mode Dirty H2O Alarm Press ENTER to set to active or inactive Sounds alarm to notify wash tank water needs to be changed Press UP or DOWN arrow to advance to other screens ...

Страница 82: ... until alarm sounds Countdown starts with first wash trigger and does not stop or pause Use LEFT RIGHT arrows to move between characters Use UP DOWN arrows to at adjust each character Press ENTER when desired name is displayed Press UP or DOWN arrow to advance to other screens ...

Страница 83: ...Up to 16 characters Press ENTER to modify setting Use LEFT RIGHT arrows to move between characters Use UP DOWN arrows to at adjust each character Press ENTER when desired name is displayed Press UP or DOWN arrow to advance to other screens ...

Страница 84: ... Mode Alarm Volume Sets volume of audible detergent alarm Press ENTER to modify setting Use UP or DOWN arrows to adjust volume Press ENTER when desired volume is reached Press UP or DOWN arrow to advance to other screens ...

Страница 85: ...oint Maintains detergent level with concentration probe Press ENTER to modify setting Use UP DOWN arrows to adjust concentration set point DEMA units Press ENTER when desired setting is displayed Press UP or DOWN arrow to advance to other screens ...

Страница 86: ...ls how quickly set point is reached high feed rate can lead to over shooting Press ENTER to modify setting Use UP DOWN arrows to adjust feed rate Press ENTER when desired setting is displayed Press UP or DOWN arrow to advance to other screens ...

Страница 87: ...elay Amount of time before detergent alarm sounds Press ENTER to modify setting Use UP DOWN arrows to adjust time setting minutes seconds Press ENTER when desired setting is displayed Press UP or DOWN arrow to advance to other screens ...

Страница 88: ...d Limit Limits the amount of time that the detergent pump will run without reaching set point Press ENTER to modify setting Use UP DOWN arrows to adjust feed limit in minutes and seconds Press DOWN arrow to advance to alarm delay ...

Страница 89: ...tration Mode Rinse Speed Adjust rinse pump speed Press ENTER to modify setting Use UP DOWN arrows to adjust rinse speed Press ENTER when desired speed is displayed Press UP or DOWN arrow to advance to other screens ...

Страница 90: ...type only Rinse length should match the amount of rinse time per rack Allows Titan II to count racks on a conveyor machine Use UP DOWN arrows to adjust rinse length Press ENTER when desired length is displayed Press UP or DOWN arrow to advance to other screens ...

Страница 91: ...lay For door machine only Adjust delay time to start rinse pump Press ENTER to modify setting Use UP DOWN arrows to adjust rinse delay Press ENTER when desired rinse delay is displayed Press UP or DOWN arrow to advance to other screens ...

Страница 92: ...t For door machine only Sets maximum rinse pump run time Press ENTER to modify setting Use UP DOWN arrows to adjust rinse limit seconds Press ENTER when desired rinse limit is displayed Press UP or DOWN arrow to advance to other screens ...

Страница 93: ...n Mode Sanitizer Speed Adjust sanitizer pump speed Press ENTER to modify setting Use UP DOWN arrows to adjust sanitizer speed Press ENTER when desired speed is displayed Press UP or DOWN arrow to advance to other screens ...

Страница 94: ... Mode Sanitizer Mode Press ENTER to modify setting Use UP or DOWN arrows to change between Run with Rinse or Run with Detergent Press ENTER when desired mode is displayed Press UP or DOWN arrow to advance to other screens ...

Страница 95: ...ord 4 numbers Press ENTER to modify setting Use LEFT RIGHT arrows to move between numbers Use UP DOWN arrows to at adjust each number Press ENTER when desired code is displayed Press LEFT arrow to confirm setting Press UP or DOWN arrow to advance to other screens ...

Страница 96: ...ENTER Concentration Mode End Programming Press ENTER to exit programming ...

Страница 97: ...xisting Programming The following outlines the order of the programming features when changing an existing Titan II program Order of programming screens changes from a new system but all screens features are available to be changed ...

Страница 98: ...ENTER System Access Allows editing of existing programming Press ENTER to begin editing ...

Страница 99: ...em Access Allows editing of the following Dispenser set up parameters Concentration parameters Probeless parameters Rinse control parameters Sanitizer set up parameters Diagnostic mode Press ENTER to gain access ...

Страница 100: ...DOWN arrow to scroll through Rack count Control mode Machine type Trigger mode Dirty H20 alarm Dirty water time Company name Alarm volume Enter new code Press ENTER when desired feature is displayed for editing Use return to system access screen or LEFT arrow to return to master menu ...

Страница 101: ...R Rack Count and Reset Displays number of rack counts registered Rack counts are generated by rinse length in conveyor mode or machine operations in door mode Press ENTER to reset and LEFT arrow to confirm ...

Страница 102: ...s concentration parameters Use the DOWN arrow to scroll through Concentration set point Feed rate Alarm delay Feed limit Press ENTER when desired feature is displayed for editing Use return to system access screen or LEFT arrow to return to master menu ...

Страница 103: ...ers Use the DOWN arrow to scroll through Recharge time Dead cycles Dwell time Initial charge Charge clock Detergent alarm Detergent type Press ENTER when desired feature is displayed for editing Use return to system access screen or LEFT arrow to return to master menu ...

Страница 104: ...ers Use the DOWN arrow to scroll through Door Rinse speed Rinse delay Rinse limit Rinse length Probeless only Conveyor Rinse speed Rinse length Press ENTER when desired feature is displayed for editing Use return to system access screen or LEFT arrow to return to master menu ...

Страница 105: ...NTER to access sanitizer set up parameters Use the DOWN arrow to scroll through Sanitizer speed Sanitizer mode Press ENTER when desired feature is displayed for editing Use return to system access screen or LEFT arrow to return to master menu ...

Страница 106: ...gain access to diagnostic mode Use the DOWN arrow to view the following screens Detergent mode and input screen The over feed switch screen The open and short screen Use return to system access screen or LEFT arrow to return to master menu ...

Страница 107: ...Information Screen DET P Probeless mode C Concentration mode Active feeding Active trigger SP Detergent set point in concentration probe mode Can be used as low level alarm for probeless mode Input Actual probe reading ...

Страница 108: ...ENTER Detergent Information Screen DET Probeless Mode Initial charge Top off recharge Dwell cycle DET Concentration Mode Received trigger adding product Received trigger not adding product ...

Страница 109: ...ENTER Over Feed Switch Displays the occurrence of auto switch overs to probeless due to concentration mode unable to climb to set point Press ENTER to reset and LEFT arrow to confirm ...

Страница 110: ...ENTER Probe Open and Short Displays the occurrence of both open and short probe conditions Press ENTER to reset and LEFT arrow to confirm ...

Страница 111: ...ENTER End Programming Press ENTER to exit programming ...

Отзывы: