DEMA 633GAP Series Скачать руководство пользователя страница 1

 

DEMA BLEND CENTER 

 

MODELS: 633GAP 

 INSTALLATION INSTRUCTIONS 

I-784 

 

Pg. 1 of 6 

Rev. J-42084                                                                               9/8/16

 

 

The 633GAP Series Blend Center modular design lets you easily couple together any number of stations to create a system that meets 
your specific needs.  Mix and match both high and low flow units for filling spray bottles, buckets, sinks and other reservoirs.  Choose 
from blue, red, green, yellow, black and white buttons. 

 

1.

 

PARTS: 

ITEM 

DESCRIPTION 

QTY. 

A.

 

  

Blend Center Assembly 

B.

 

 

¼” ID or 3/8" I.D.  X 8’ Long Vinyl Supply Tubing & Foot Valve Assembly 

C.

 

 

Ceramic Weight For 1/2” OD or 3/8" OD Vinyl Supply Tubing 

D.

 

 

½” ID X 6” Long Vinyl Outlet Tubing (For 1 GPM Station Only) or 
½” ID X 6’ Long Vinyl Outlet Tubing (For 4 GPM Station Only) 

E.

 

 

#10 Screws & Anchor Kit Set (2 #10 Screws & 2 #10 Anchors 

F.

 

 

Chemical Label 

G.

 

 

Metering Tip Kit 

 

 

 

 

2.

 

INSTALLATION:

 

Note:  All  installations  must  conform  to  local  plumbing  codes  and  use  the  approved  backflow  preventers.  Pressure 
indicating tee is to be installed with existing faucets according to  local plumbing codes in the state of Wisconsin and any 
other state that requires the use of a pressure indicating tee. 
WARNING: Water supply should not exceed 125 psi and water temperature must not exceed 150°F. 

 

A.

 

Mounting & Water Supply: 

Remove the two cover retainer screws and the cover from the Blend Center assembly.  Any 

number of Blend Centers can be coupled together by first removing the pipe plugs in all but the last unit, then connecting 
the male hose thread of one unit to the female inlet hose adapter of the next unit.  Mount the unit(s) in position on the wall 
and locate the position for the mounting screws.  Only two screws are necessary to mount up to four units coupled together.  
Drill  all  of  the  holes  into  the  drywall  using  a  ¼”  diameter  bit  for  use  with  the  included  #10  screw  and  anchor  set.    (If 
mounting the Blend Center to wood and you do not plan to use the included anchors, drill 1/8” diameter holes.)  Insert the 
anchors into drilled holes and hammer them into the wall until they are flush with face of wall.  Mount the units(s) to the 
wall and replace the covers and screws. 
The water inlet is equipped with a female garden hose fitting (with strainer washer) for attaching a water supply hose.  The 
unit is designed so water can be supplied to either side by interchanging the pipe plug and the female hose fitting.  

Note: 

Apply pipe dope, hand-tighten, and then turn 1-1/2 times with a wrench.

  

DO NOT OVER TIGHTEN. 

 

WARNING: Do not use Teflon® tape to seal internal plastic threads as the extra thickness of the tape may 
cause the plastic to crack.  Use a non-welding liquid sealant instead. 

 

B.

 

Pressure  Indicating  Tee  Installation: 

Screw  female  quick 

disconnect to faucet and attach pressure indicating tee to female 
quick disconnect.  Attach female end of reinforced hose to male 
threads  of  tee,  then  attach  the  male  end  to  the  female  garden 
hose fitting at the water inlet of the Blend Center (See Figure to 
the right).   

 

C.

 

Chemical  Supply: 

Place  the  chemical  containers  in  a 

convenient  location  not  more  than  6  feet  below  the  Blend 
Center  (greater  lifts  will  reduce  injection  capacities).    Slip 
ceramic  weight  over  the  chemical  supply  tubing  and  insert  the 
foot  valve  end  of  the  tubing  into  the  chemical  container.    Cut 
the  vinyl  tubing  to  any  convenient  length  that  will  allow  the 
chemical  supply  tubing  to  extend  from  the  bottom  of  the 
chemical  container  to  the  proportioner  inlet  barb.    (See  Figure 
1)  Install the tubing by pushing tubing over the barb located on 
the  proportioner.  Gummed  labels  are  provided  for  labeling 
chemicals. 

 

D.

 

Outlet  Tubing: 

Cut  the  1/2"  I.D.  outlet  tubing  to  the  desired 

length and attach it to the proportioner outlet barb.  

NOTE: DO 

NOT force outlet tubing onto the larger barbs on the proportioner. 

  

 

Отзывы: