V. SERVICING:

 

CAUTION:

  

Turn off water supply before servicing.

 

 
A. 

Failure to inject chemical? 
1.

 

Low water pressure.  At least 15 psi is required. 

2.

 

Dirt or chemical on outlet screens.  Clean. 

3.

 

Blue button does not seal when pushed.  Remove and inspect for dirt or damage. 

4.

 

Chemical passage blocked.  Remove metering tip, then remove proportioner and soak in hot water to clean internal passages. 

5.

 

Foot valve clogged.  Soak in hot water. 

6.

 

Lime deposits in water passages.  Remove proportioner and soak in deliming solution. 

7.

 

Conical inlet screen 150-34 is dirty or missing.  Clean or replace. 

 

B. Injects 

continuously? 

1. 

Button fails to reset because of damage to button, retainer or spring. 

2. 

Vacuum breaking air vents in button retainer are clogged with grease or dirt.  Clean. 

3. 

Chemical container above level of faucet.  Place container on floor. 

 

CAUTION:

  

When servicing unit be sure that replacement parts have been installed according to drawing. 

 
 
 

RETURNS:

   

NO MERCHANDISE MAY BE RETURNED FOR CREDIT WITHOUT DEMA’S WRITTEN 
PERMISSION.  RETURN MERCHANDISE AUTHORIZATION NUMBER REQUIRED IN 
ADVANCE OF RETURN. 

 
WARRANTY:

 

DEMA products are warranted against defective material and workmanship under normal use and 
service for one year from the date of manufacture.  This limited warranty does not apply to any 
products which have a normal life shorter than one year or failure and damage caused by chemicals, 
corrosion, improper voltage supply, physical abuse, or misapplication.  Rubber and synthetic rubber 
parts such as “o”- rings, diaphragms, squeeze tubing and gaskets are considered expendable and are 
not covered under warranty.  This warranty is extended only to the original buyer of DEMA 
products.  If products are altered or repaired without prior approval of DEMA, this warranty will be 
void. 

 

 

 

 

Defective units or parts should be returned to the factory with transportation prepaid.  If inspection 
shows them to be defective, they will be repaired or replaced without charge, F.O.B. factory.  DEMA 
assumes no liability for damages.  Return merchandise authorization number, to return units for 
repair or replacement, must be granted in advance of return. 

 

 

 

 

 
 
 
 
 
 
 
 
 
 
 

Содержание 153

Страница 1: ... USE Always read SDS for all chemicals used and follow personal protective guidelines Screw proportioner directly onto garden hose type faucets Remove inlet adapter for mounting onto standard external aerator threads For other faucets see reverse side for adapter part numbers Select a metering tip See section IV and screw it into inlet barb See figure 1 Cut vinyl tubing to any convenient length sl...

Страница 2: ...0 640 1 0 17 753 1 0 15 853 1 Orange 0 33 384 1 0 30 427 1 0 25 512 1 0 20 640 1 Turquoise 0 50 256 1 0 40 320 1 0 33 384 1 0 25 512 1 Pink 0 63 203 1 0 50 256 1 0 45 284 1 0 33 384 1 Clear 0 75 171 1 0 70 183 1 0 60 213 1 0 45 284 1 Brown 1 00 128 1 0 85 151 1 0 70 183 1 0 50 256 1 Red 1 25 116 1 1 00 128 1 0 80 160 1 0 60 213 1 White 1 50 85 1 1 25 102 1 1 00 128 1 0 70 183 1 Green 1 75 73 1 1 5...

Страница 3: ...rding to drawing RETURNS NO MERCHANDISE MAY BE RETURNED FOR CREDIT WITHOUT DEMA S WRITTEN PERMISSION RETURN MERCHANDISE AUTHORIZATION NUMBER REQUIRED IN ADVANCE OF RETURN WARRANTY DEMA products are warranted against defective material and workmanship under normal use and service for one year from the date of manufacture This limited warranty does not apply to any products which have a normal life ...

Страница 4: ...DEMA 153 FAUCET PROPORTIONER INSTALLATION INSTRUCTIONS I 103 Pg 4 of 5 Rev E 34613 6 26 09 ...

Страница 5: ...3 8 OD x 50 Lg Supply Tubing 12 100 12L 3 8 ID x 1 2 OD x 8 Lg Supply Tubing NO PART NO DESCRIPTION 13 100 12LE 3 8 ID x 1 2 OD x 50 Lg Supply Tubing 14 61 107 2 Ceramic Weight 15 100 16E Foot Valve 16 100 52 Repair Kit NO PART NO DESCRIPTION 17 150 23 Outside Chicago Thread Adapter 18 150 21 Inside Aerator Thread Adapter 19 150 32 Inside Kohler Thread Adapter 20 150 9 2 Irregular Faucet Adapter 2...

Отзывы: