RMC200 Startup Guide
38
Delta Computer Systems, Inc.
S8: SSI Transducer Wiring
For Synchronous Serial Interface (SSI) transducers and encoders.
For linear SSI transducers, make sure to choose the synchronized type.
S8
Clock +
Clock -
Data +
Data -
Power Supply
+Pwr
Cmn
Clk+
Clk-
Cmn
Dat+
Dat-
Case
Pwr+
DC Gnd
Tip:
See next page
for manufacturer-specific wiring diagrams.
Notes:
•
The user must supply power to the transducer.
•
Connect the encoder DC ground to the Cmn pin on the S8
module. The Cmn must be connected to the transducer, or the
signals may not be read correctly!