08 Warnings and Error Codes | REG2000
8-1
08 Warnings and Error Codes
This chapter contains information on the optional digital keypad display (KPC-CC01/KPC-CE01). If you did
not purchase the optional digital keypad, you can find out about error signals through the RS-485
communication interface.
※
When a Power Regenerative Unit is at STOP, it is between the Ready status and the Run status (see
Section 4-4 Display Panel Indicators for the definition of different working status of power
regeneration).
※
This chapter helps on-site technicians with troubleshooting. If the warning/error remains after
following the corrective actions, contact a local dealer near you or Delta to return this product.
Warnings Codes
HAND
CE01
Comm. Error 1
Warning
Display error code (abbreviation)
This error code is the same as displayed on the digital controller (KPC-CE01)
Display error type
Display error description
➀
➁
➀
➁
➂
➂
ID #
LCM panel display
Description
1
CE1
Comm. Error1
Warning
Communication Warning 1: Illegal communication command
Corrective Action
Verify that the communication wring is correct (see Section 4-3).
Verify that the related parameter settings are in the correct setting
ranges (see Chapter 07
Descriptions of Parameter Settings).
Press the RESET button after verifying the above items. If the warning
message still appears, contact a local dealer near you or Delta to return
this product.
2
CE2
Comm. Error 2
Warning
Communication Warning 2: Illegal communication data address
Corrective Action
Verify that the communication wring is correct.
Verify that the communication command is correct.
Press the RESET button after verifying the above items. If the warning
message still appears, contact a local dealer near you or Delta to return
this product.
3
CE3
Comm. Error 3
Warning
Communication Warning 3: Illegal communication data value
Corrective Action
Verify that the communication wiring is correct.
Verify that the communication command is correct.
Press the RESET button after verifying the above items. If the warning
message still appears, contact a local dealer near you or Delta to return
this product..
Содержание REG2000 Series
Страница 44: ...04 Wiring REG2000 4 20 4 4 Display Panel Indicators Display Panel...
Страница 51: ...05 Optional Accessories REG2000 5 5 How to remove the plastic cap 1 Press the pin on top of the keypad...
Страница 67: ...05 Optional Accessories REG2000 5 21 5 5 External Power Supply Card 24 V EMC BPS01 Installing the EMC BPS01...
Страница 68: ...05 Optional Accessories REG2000 5 22 Removing the EMC BPS01...