1.  Safety Instructions

•  Must select correct AC input voltage range through selectable switch before turning on (Refer to 

Fig. 1, 

).

• 

To ensure sufficient convection cooling, always maintain a safety distance of ≥ 20 mm from all 

ventilated surfaces while the device is in operation.

• 

The device is not recommended to be placed on low thermal conductive surface, for example, 

plastics.

• 

Note that the enclosure of the device can become very hot depending on the ambient temperature 

and load of the power supply. Do not touch the device while it is in operation or immediately after 

power is turned OFF. Risk of burning!

• 

Do not touch the terminals while power is being supplied. Risk of electric shock.

• 

Prevent any foreign metal, particles or conductors to enter the device through the openings during 

installation. It can cause: Electric shock; Safety Hazard; Fire; Product failure

• 

Battery need to be protected from short circuit while installation & servicing. Danger of explosion.

• 

Signal cable should not interact with AC Input.

• 

Warning: When connecting the device, secure Earth connection before connecting L and N. When 

disconnecting the device, remove L and N connections before removing the Earth connection.

2.  Device Descriptions

Refer to Fig. 1.:

 

Input & Output terminal block connector

 

DC voltage adjustment potentiometer (12Vdc - 14Vdc)

 

Green  LED  ON  =  DC  OK  (Normal  operation  through  mains  supply  or  through  battery  when 

 

operating in buffering mode)

 

մ

Red LED ON = Battery reverse polarity

 

յ

Battery charging current adjustment potentiometer (Factory Setting: 1A)

Max charging current shall not exceed 1.5A (Refer to Fig. 1, 

). 

 

ն

AC selectable switch

 

Signal connector - JST: XHP-4 (for PMU-13V155WCCA only)

3.  Installation of the Device

Refer to Fig. 2.: 

 

Mounting holes for the power supply assembly onto the mounting surface. The power supply shall 

be mounted on minimum 2 mounting holes using M3 screw minimum 5 mm length.

 

This surface belongs to customer’s end system or panel where the device is mounted.

 

Connector

• 

Use flexible cable (stranded or solid), AWG No. 16-14. 

• 

The torque at the Connector shall not exceed 13 Kgf.cm. The insulation stripping length should not 

exceed 0.275” or 7 mm (Refer to Fig. 3).

4.  Battery Information*

Battery Capacity

3.2AH - 15AH

*For more information, please refer to the product datasheet. 

5.  Installation of Mounting Accessories

Refer to Fig. 4.:

• 

Only use M3 screw ≤ 2.5 mm through the base mounting holes. This is to keep a safety distance 

between the screw and internal components.

• 

Recommended mounting tightening torque: 4~8 Kgf.cm.

www.DeltaPSU.com

REV.02

Fig. 1. Device Descriptions

Fig. 3. Wire Type

Fig. 4. Mounting Screw

Lug

Stripped wire

Mounting

accessories

Mounting

screw

Chassis of 

the device

2.5mm

max.

7 mm

Side Mounting (Vertical)

Base Mounting (Vertical)

Side Mounting (Horizontal)

A

B

A

B

A

C

C

C

B

A

B

A

B

A

C

C

C

B

A

B

A

B

A

C

C

C

B

Fig. 2. Mounting Orientation

Base surface

Top surface

Ventilated surface

Side surface

1

2

3

5

4

6

PMU-13V155WCBA (no signal connector)

PMU-13V155WCCA (with signal connector)

Base surface

Top surface

Ventilated surface

Side surface

1

2

5

6

7

3

4

Pin No.

1

2

3

4

DC OK

Low Battery

GND

AC OK

Description

7

Signal connector

JST: XHP-4

400mm.(Ref.)

Содержание PMU-13V155WC A Series

Страница 1: ...ty յ Battery charging current adjustment potentiometer Factory Setting 1A Max charging current shall not exceed 1 5A Refer to Fig 1 ն AC selectable switch Signal connector JST XHP 4 for PMU 13V155WCCA only 3 Installation of the Device Refer to Fig 2 䑵 Mounting holes for the power supply assembly onto the mounting surface The power supply shall be mounted on minimum 2 mounting holes using M3 screw ...

Страница 2: ... 配件組合安裝 依據圖四 在把配件裝上產品時 請使用伸入產品長度不超過 2 5 mm 的 M3 螺絲鎖入產品底面的固定 孔 這是為了確保螺絲和內部元件間有足夠的絕緣距離 建議配件固定螺絲扭矩為 4 8 Kgf cm 1 1 安全规范 安全规范 通电前需选择正确的交流输入电压 依据图一 的位置 与通风表面保持至少 20 mm 的安全距离 以确保对流冷却充分 本产品不适合摆放在低热导体 例如 塑胶 受环境温度及产品负载的影响 本机外壳温度会很高 因此在上电时或切断电源后短时间内 不要触摸本机 以免烫伤 请勿在上电时触摸连接端子 以防电击危险 安装过程中 应避免金属元件或金属导体通过空隙或通风孔进入到产品内 否则会引起下列 状况 电击 安全危害 火灾 产品异常 当安装和维修时 需要保护电池以避免短路进而防止发生爆炸的危险 信号线不能与交流输入线缠绕在一起 以免交互影响 警告 在连接产品电源供应时...