background image

 

www.DeltaPSU.com 

REV.00 

Instruction Manual

   

 

 

1.  Safety Instructions 

 

If user’s mounting orientation is not according to the recommended mounting orientations, 

please consult Delta for further information. 

 

To  ensure sufficient 

convection  cooling,  always  maintain  a  distance  of  ≥

 20mm from 

ventilated surfaces while the device is in operation. 

 

The device is not recommended to be placed on low thermal conductive surface. For 

example, plastics. 

 

The enclosure of the device can become very hot depending on the ambient temperature 

and load  of the power supply. Do not touch the device while it is in operation or 

immediately after power is turned OFF. Risk of burning! 

 

Do not touch the terminals while power is being supplied. Risk of electric shock. 

 

Prevent any foreign metal, particles or conductors from entering the device through the 

openings during installation. It may cause electric shock, safety hazard, fire and/or product 

failure.

 

 

Warning: When connecting the device, secure Earth connection before connecting L and 

N.  When disconnecting the device, remove L and N connections before removing the 

Earth connection. The power supply must be mounted by metal screws onto a grounded 

metal surface. It is highly recommended that the Earth terminal on the connector be 

connected to the grounded metal surface.

 

 

 

2.  Device Descriptions 

Refer to Fig. 1.:

 

 

1     Input & Output terminal block connector 

DC voltage adjustment potentiometer (Option) 

DC OK control LED (Green)  

DC OK relay contact (Option)

 

 

 

3.  Installation of the Device 

A      Side Mounting: Fig. 2 and Fig. 3 show the mounting hole locations for power supply 

assembly onto a metal mounting surface. The power supply shall be mounted on 

minimum of 2 mounting holes using M4 screw of maximum 5mm length (Refer to Fig. 

5). This is to maintain a safety distance between the screw and internal components. 

B      Base Mounting: Fig. 2 and Fig. 3 show the mounting hole locations for power supply 

assembly onto a metal mounting surface. The power supply shall be mounted on 

minimum of 4 mounting holes using M4 screw of maximum 4mm length (Refer to Fig. 

5). This is to maintain a safety distance between the screw and internal components. 

C      Fig. 2: Connector  

D      Fig. 2: This surface belongs to customer’s end system or panel where the device is 

mounted. 

 

 

Use flexible cable (stranded or solid) of AWG No. 20-12. The input/output connectors’ 

allowable current is 23A max per pin. User should calculate and select the suitable wire 

specification (type/quantity/diameter) according to actual output current. The torque at the 

connector shall not exceed 13Kgf.cm. The insulation stripping length should not exceed 

0.275” or 7mm (Refer to Fig. 4).

 

 

 

Recommended mounting torque of the product and its mounting accessories is 

9~12Kgf.cm. 

 

4.  Top Fixing Bracket (Option) 

 

For more information about the accessory, please refer to the  corresponding  technical 

datasheet at www.DeltaPSU.com. 

 

PMR-

V320WD

☐☐

 

Fig. 5. Assembly Reference

 

Fig. 4. Wire Type

 

Lug 

Stripped wire 

Base Mounting (Horizontal) 

Base Mounting (Vertical) 

Fig. 2. Recommended Mounting Orientations

 

Fig. 1. Device Descriptions 

PMR-

V320WDG

, PMR-

V320WDC

 

 (Front Face Terminal Block)

 

 

PMR-

V320WDA

, PMR-

V320WDB

 

(Standard Terminal Block)

 

 

Fig. 3. Mounting Hole Locations

 

All manuals and user guides at all-guides.com

Отзывы: