background image

          Instruction Manual 

 

 

 

   

 

                                                                                                         

PMC-24V300W1BA

 

 

1.  Safety instructions

 

 

     T o   e n s u r e   s u f f i c i e n t   f a n   c o o l i n g ,   a l w a ys   m a i n t a i n   a   s a f e t y    

distance of >20mm between fan and socket side surfaces while the 
device is in operation. 

     T he  device  is  not  recomm ended  to  be  placed  on  low  therm al         

       conductive surface, for example, plastics. 

     N o te   t h a t  t h e  e nc l os u r e  of   t h e  d ev ic e  c a n  be c om e  v e r y  ho t   

       depending  on  the  ambient  temperature  and  load  of  the  power  supply.        
       Do  not  touch  the  device  while  it  is  in  operation  or  immediately  after    
       power is  turned OFF. Risk of burning

!

 

     Do  not  touch  the  terminals  while  power  is  being  supplied.  Risk  of     

       electric shock. 

     Prevent  any  foreign  metal,  particles  or  conductors  to  enter  the  device   

       t h r o u g h   t h e   o p e n i n g s   d u r i n g   i n s t a l l a t i o n .   I t   c a n   c a u s e : - 

   -   E l e c t r i c   s h o c k ;   S a f e t y   H a z a r d ;   F i r e ;   P r o d u c t   f a i l u r e 

     W arning:  W hen  connecting  the  device,  secure  Earth  connection   

       before  connecting  L  and  N.  When  disconnecting  the  device,  remove   
       L  a n d  N  co n nec tio ns  be fo re   rem o vin g  t he  E art h  c on ne cti on . 

 

2.  Device descriptions 

 

Refer to Fig.1.:  

 

1

     Input & Output terminal block connector 

2

 

DC voltage adjustment potentiometer 

3

 

DC OK control LED (green) 

4

 

Remote Sense Function & 12V STANDBY / 0.5A 

5

 

DC - FAN 

 

3.  Installation of the Device 

 

                  Refer to Fig. 2.: 

   Mounting holes 

   Input / Output connector 

   Mounting surface (customer) 

   DC FAN 

 

 

     Use flexible cable (solid), AWG no. 20-16. The torque at  the  

 Connector shall not exceed 13Kgf.cm The insulation stripping length    
 

should not exceed 0.275″ or 7mm Refer to Fig. 3. 

 

 

          4. Installation of Mounting Accessories 

 

     Only use M4 screw < 4.5mm through the base mounting holes. This is  to 

 keep a safety distance between the screw

 

and internal components.  

     Refer to Fig. 4.:  

 Recommended mounting tightening torque : 4~8Kgf.cm 

       

 

 
 
 
 
 
 
 
 

 

 
 
 
 
 

 

 

 

 

 

 
 
 
 

 

    

 

 
 
 
  
 

www.deltapsu.com 

REV.02 

All manuals and user guides at all-guides.com