background image

Instruction Manual

PMC-12V060W1N

www.DeltaPSU.com

1.  Safety Instructions

•  To ensure sufficient convection cooling, always maintain a safety distance of    

≥ 20mm from all ventilated surfaces while the device is in operation.

•  The  device  is  not  recommended  to  be  placed  on  low  thermal  conductive 

surface, for example, plastics.

•  Note that the enclosure of the device can become very hot depending on the 

ambient temperature and load of the power supply. Do not touch the device 

while it is in operation or immediately after power is turned OFF. Risk of burning!

•  Do not touch the terminals while power is being supplied. Risk of electric shock.

•  Prevent any foreign metal, particles or conductors to enter the device through 

the openings during installation. It can cause: Electric shock; Safety Hazard; 

Fire; Product failure

•  Warning:  When  connecting  the  device,  secure  Earth  connection  before 

connecting  L  and  N.  When  disconnecting  the  device,  remove  L  and  N 

connections before removing the Earth connection.

2.  Device Descriptions

Refer to Fig. 1.:

 

Input & Output terminal block connector

 

DC voltage adjustment potentiometer

 

DC OK control LED (Green)

3.  Installation of the Device

Refer to Fig. 2.: 

 

Mounting  holes  for  power  supply  assembly  onto  the  mounting  surface. The 

power supply shall be mounted on minimum 2 mounting holes using M3 screw 

minimum 5mm length.

 

This  surface  belongs  to  customer’s  end  system  or  panel  where  the  power 

supply is mounted.

 

Connector

•  Use flexible cable (stranded or solid) with the following sizes:

•  The  torque  at  the  Connector  shall  not  exceed  13  Kgf.cm.  The  insulation 

stripping length should not exceed 0.275” or 7mm (Refer to Fig. 3).

4.  Installation of Mounting Accessories

Refer to Fig. 4.:

•  Only use M3 screw ≤ 6mm through the base mounting holes. This is to keep a 

safety distance between the screw and internal components.

•  Recommended mounting tightening torque: 4~8 Kgf.cm.

REV.00

Fig. 1. Device Descriptions

PMC-12V060W1NA (Standard Connector)

PMC-12V060W1NJ (IP20 Connector)

PMC-12V060W1NL (Front Face Connector)

Fig. 3. Wire Type

Fig. 4. Mounting Screw

Lug

Stripped wire

Mounting

accessories

Mounting

screw

Chassis of 

the device

6mm max.

7 mm

Fig. 2. Mounting Orientation

Side Mounting (Vertical)

Base Mounting (Vertical)

Side Mounting (Horizontal)

B

C

A

A

C

B

B

A

C

B

C

A

A

C

B

B

A

C

B

C

A

A

C

B

B

A

C

Side Surface

Top Surface

Ventilated Surface

Base Surface

1

2

3

Ventilated Surface

Side Surface

Side Surface

2

3

1

Ventilated Surface

Side Surface

Side Surface

2

3

1

PMC-12V060W1NH (Harness Connector)

PMC-12V060W1NA

PMC-12V060W1NJ

PMC-12V060W1NL

AWG 22-14

AWG 22-12

AWG 22-12

Ventilated Surface

Side Surface

Side Surface

1

2

3

All manuals and user guides at all-guides.com

Отзывы: