          Instruction Manual 

 

 

 

   

 

                                                                                                         

PMC-12V050W1AA

 

 

1.  Safety instructions

 

 

     To  ensure  sufficient  convection  cooling,  always  maintain  a   safety    

       distance  of  >20mm  from  all  ventilated  surfaces  while  the  device  is  in       
       operation. 

     T he  device  is  not  recomm ended  to  be  placed  on  low  therm al         

       conductive surface, for example, plastics. 

     N o te   t h a t  t h e  e nc l os u r e  of   t h e  d e v ic e  c a n  be c om e  v e r y  ho t   

       depending  on  the  ambient  temperature  and  load  of  the  power  supply.        
       Do  not  touch  the  device  while  it  is  in  operation  or  immediately  after    
       power is  turned OFF. Risk of burning

!

 

     Do  not  touch  the  terminals  while  power  is  being  supplied.  Risk  of     

       electric shock. 

     Prevent  any  foreign  metal,  particles  or  conductors  to  enter  the  device   

       t h r o u g h   t h e   o p e n i n g s   d u r i n g   i n s t a l l a t i o n .   I t   c a n   c a u s e : - 

   -   E l e c t r i c   s h o c k ;   S a f e t y   H a z a r d ;   F i r e ;   P r o d u c t   f a i l u r e 

     W arning:  W hen  connecting  the  device,  secure  Earth  connection   

       before  connecting  L  and  N.  When  disconnecting  the  device,  remove   
       L  a n d  N  co n nec tio ns  be fo re   rem o vin g  t he  E art h  c on ne cti on . 

 

2.  Device descriptions 

 

Refer to Fig. 1.: 

 

1

     Input & Output terminal block connector 

2

 

DC voltage adjustment potentiometer 

3

 

DC OK control LED (green) 

 

3.  Installation of the Device 

 

                  Refer to Fig. 2.: 

   Mounting  holes  for  power  supply  assembly  onto  the  mounting  surface. 

 

 

 

   Power supply shall be mounted on minimum 2 mounting  holes using M3 

 

 

 

   screw minimum 5mm length.       

   T

his surface belongs to customer’s end system or panel where the    

           

              power supply is mounted. 

   Connector 

 

 

     Use flexible cable (stranded or solid), AWG no. 22-14. The torque at  the  

 Connector  shall  not  exceed  13Kgf.cm  The  insulation  stripping  length    
 should not exceed 0.275

″ or 7mm Refer to Fig. 3. 

 

 

          4. Installation of Mounting Accessories 

 

     Only use M3 screw < 6mm through the base mounting holes. This is  to 

   keep a safety distance between the screw

 

and internal components.  

     Refer to Fig. 4.:  

 Recommended mounting tightening torque : 4~8Kgf.cm 

        

 

 
 
 
 
 
 
 

 

 
 
 
 
 
 

 

 

 

         

 

 

 

 

 

 
 
 
 

 

    

 

 
 
 
 
 
 

   

     

 

Fig. 1.  Device Descriptions 

www.deltapsu.com 

Fig. 4. Mounting Screw 

Fig. 2.  Mounting Orientation

 

Side Mounting (Vertical) 

Base Mounting (Vertical)   Side Mounting (Horizontal) 

Fig. 3. Wire Type 

Lug 

Stripped wire 