background image

Instruction Manual

PJB-24V300W

☐☐☐

www.DeltaPSU.com

1. Safety Instructions

•  The device is not recommended to be placed on low thermal conductive surface.  

   For example, plastics. 

• For safety reasons, please ensure the mounted device is kept for 

Open Frame Type

 ≥ 8mm, 

 

  for

 Case Type

  ≥  4mm  safety  distance  at  all  sides  from  other  components  and  equipments

 

   (Refer to Fig. 2.:). Please insert an insulation sheet between the system and product, if the safety 

   distance is < 4mm. 

•  Note that the enclosure of the device can become very hot depending on the ambient 

   temperature and load of the power supply. 

•  Do not touch the device while it is in operation or immediately after power is turned OFF.  

   Risk of burning! 

•  Do not touch the terminals while power is being supplied. Risk of electric shock. 

•  Prevent any foreign metal, particles or conductors from entering the device through the 

   openings during installation. It may cause: - Electric shock; Safety Hazard; Fire; Product failure.

•  Warning: The power supply must be mounted by metal screws onto a grounded metal surface. 

   It is highly recommended that the Earth terminal on the connector be connected to the grounded 

   metal surface. 

   For Open Frame type of installation, ensure the power supply’s Protective Earthing   

   (Marked “PE” in Fig. 1) point is connected to the system’s Protective Earthing (PE). It is   

   also recommended that the input FG (Fig. 1 location 1) be connected to the system’s PE. 

2. Device Descriptions 

(Refer to Fig. 1.:)

 Input terminal block connector

 Output terminal block connector (V-)

 Output terminal block connector (V+)

 Remote ON/OFF function connector (Option)

 DC voltage adjustment potentiometer

 

3. Installation of the Device 

(Refer to Fig. 1.:)

   Ⓐ 

Mounting holes for the Enclosed type of power supply (device). The device shall be mounted on 

            minimum of 3 mounting holes using M4 screw of minimum 4mm length. Recommended mounting 

            torque for tightening: 8~10Kgf.cm. For the other mounting holes without screw threads,

 

           please use suitable screw and nut. 

           Mounting holes for the Open Frame type of power supply (device). The device shall be 

           mounted on minimum of 4 mounting holes using #6-32 screw of minimum 4mm length. 

           Recommended mounting torque for tightening: 6~8Kgf.cm. 

   

   Ⓑ 

This surface belongs to customer’s end system or panel where the device is mounted.

•   Use flexible cable (stranded or solid) of AWG No. 22-16. Please refer the table below for the 

    recommended housing and terminal. 

•   For the Remote ON/OFF function, use flexible cable (stranded or solid) of AWG No. 28-22.

REV.01

Fig. 2. Assembly Reference

For Open Frame: D1 = 8 mm, D2 = 8 mm  

For L Frame / Enclosed: D1 = 4 mm

If place metal plate on the bottom of PCB, 

please connect to PE.

Fig. 1. Device Descriptions

PJB-24V300WC

A: Enclosed (cover and chassis)

PJB-24V300WC

J: Enclosed (cover and chassis)

PJB-24V300WL

A: L Frame (without cover)

PJB-24V300WL

J: L Frame (without cover)

TOP SIDE

FRONT SIDE

PJB-24V300WB

A: Open Frame

PJB-24V300WB

J: Open Frame

Connector (Board Mounting)

Housing

Terminal

Input (JST)

B3P5-VH(LF)(SN)

VHR-5N

SVH-21T-P1.1

Output (JST)(V-)

B7P-VH(LF)(SN)

VHR-7N

Output (JST)(V+)

B6P-VH(LF)(SN)

VHR-6N

Remote ON/OFF 

Function (Option)

B2B-XH-A(LF)(SN)

XHP-2

SXH-001-P0.6

4-M4 MOUNTING HOLES 

4-M4 MOUNTING HOLES 

4-M4 MOUNTING HOLES 

4-M4 MOUNTING HOLES 

A

A

B

B

1

2

3

4

5

V(+)

V(-)

4-M4  MOUNTING HOLES

4-M4  MOUNTING HOLES

4-M4  MOUNTING HOLES

4-M4  MOUNTING HOLES

A

B

A

B

2

3

1

4

5

V(+)

V(-)

FG

N

L

B

A

2
3

4

5

4-M4 MOUNTING HOLES

4-M4 MOUNTING HOLES

1

V(+)

V(-)

B

A

FG
N
L

2

3

4

5

4-M4 MOUNTING HOLES

4-M4 MOUNTING HOLES

1

V(+)

V(-)

Ø3.7 [0.15]

FG
N
L

3-Ø3.5 [0.14] 

(MOUNTING HOLE)

(MOUNTING HOLE)

V (-)

V (+)

PE: MUST CONNECT WITH SYSTEM PROTECTIVE EARTHING.

B

A

2

3

4

5

1

PE: MUST CONNECT WITH SYSTEM PROTECTIVE EARTHING.

Ø3.7 [0.15]

3-Ø3.5 [0.14] 

(MOUNTING HOLE)

(MOUNTING HOLE)

B

A

2

3

4

5

1

V(+)

V(-)

FG
N
L

CN1

CN1

D1

D1

D1

D1

D1

D2

Manual PJB-24V300WXXX_Rev.01_EN-CN-JP_01192020.indd   1

Manual PJB-24V300WXXX_Rev.01_EN-CN-JP_01192020.indd   1

1/20/2021   1:39:25 PM

1/20/2021   1:39:25 PM

Отзывы: