4.3
Output power and de-rating
4.3.1
Output operating area
The charger system can provide an output within the bounds of the graphs below.
24 V operating area
48 V operating area
48V operating area
Using the 48 V charger system as an example:
●
Between 24 V and 38 V the charger system can provide a maximum of 3 A
●
Between 38 V and 48 V the charger system can provide up to 20.8 A
●
Between 48 V and 60 V the charger system can provide a maximum of 1
,
000 W, and will
reduce
the output current to achieve this
4.3.2
Power vs. input voltage
The charger system can operate from an AC supply of 85 to 265
V
AC
. However when input voltage is
less than 100 V
AC
, the output power is automatically reduced to avoid the input current exceeding 13 A.