background image

 
 
 

 

 
 

MODEL: GBR100

Page 1.

INSTALLATION AND OPERATING INSTRUCTIONS 

VENTILATION FAN 
 
READ AND SAVE THESE INSTRUCTIONS 

GENERAL SAFETY INFORMATION 

1. 

Make sure that the electric service supply 
voltage is AC 120V, 60Hz. 

2. 

Follow all local electrical and safety codes, as 
well as the National Electrical Code (NEC) and 
the Occupational Safety and Health Act (OSH 
Act). 

3. 

Always disconnect the power source before 
working on or near the ventilating fan, motor or 
junction box. 

4. 

Protect the power cord from sharp edges, oil, 
grease, hot surfaces, chemicals or other 
objects. 

5. 

Do not kink the power cord. 

6. 

Do not install the unit where ducts are 
configured as shown in Fig. A. 

7. 

Provide suction parts with proper ventilation. 

8. 

This unit is UL listed for use over a bathtub or 
shower when installed in a GFCI protected 
branch circuit. 

9. 

These ventilating fans are intended for 
residential usage only. 

 

WARNING 

TO REDUCE THE RISK OF FIRE, ELECTRIC 
SHOCK, OR INJURY TO PERSONS, OBSERVE 
THE FOLLOWING: 

1. 

Use this unit only in the manner intended by the 
manufacturer. If you have questions, contact 
the manufacturer. 

2. 

Before servicing or cleaning unit, switch power 
off at service panel and lock the service 
disconnecting means to prevent power from 
being switched on accidentally. When the 
service disconnecting means cannot be locked, 
securely fasten a prominent warning device, 
such as a tag, to the service panel. 

3. 

Installation work and electrical wiring must be 
done by a qualified person(s) in accordance 
with all applicable codes and standards, 
including fire-rated construction. 

4. 

Sufficient air is needed for proper combustion 
and exhausting of gases through the flue 
(chimney) of fuel burning equipment to prevent 
back drafting. Follow the heating equipment 
manufacturer’s guideline and safety standards 
such as those published by the National Fire 
Protection Association (NFPA), and the 
American Society for Heating Refrigeration and 
Air Conditioning Engineers (ASHRAE) and the 
local code authorities. 

5. 

When cutting or drilling into the wall or ceiling, 
do not damage electrical wiring and other 
hidden utilities. 

6. 

Ducted fans must always be vented to the 
outdoors. 

7. 

If this unit is to be installed over a tub or shower, 
it must be marked as appropriate for the 
application and be connected to a GFCI 
(Ground Fault Circuit Interrupter) – protected 
branch circuit. 

8. 

Do not use this unit with any other solid-state 
control device. Solid-state controls devices may 
cause harmonic distortion, which can cause a 
motor humming noise. 

9. 

NEVER

 place a switch where it can be reached 

from a tub or shower. 

 

10.  Not to be installed in a ceiling thermally 

insulated to a value greater than R40. (This is 
required for installation in Canada only). 

Turning angle too large

Duct shrink

Too many elbows

Elbow near the body

Body

 

CAUTION

 

1. 

For general ventilating use only. Do not use to 
exhaust hazardous or explosive materials and 
vapors. 

2. 

Not for use in cooking areas. (Fig. B) 

3. 

This product must properly connect to the 
grounding conductor of the supply circuit. 

4. 

To reduce the risk of injury to persons, install 
the fan at least 7 feet (2.1m) above the floor. 

45

Cooking area

45

D o not install above or

  inside this area

 C ooking

E quipm ent

floor

 

SUPPLIED ACCESSORIES

 

Part name

Appearance 

Quantity 

Grille 

Fan 

Housing 

Duct 

Connector

(4”) 

Screw 

(

ψ

4×25)

 
 
 

1. INSTALLATIONS 

MOUNT HOUSING WITH FLANGE: 

1-1.  To bend the housing tabs out to 90 degree and 

make housing tabs contact the bottom of the 
joist. 

Tabs

Joist

 

1-2.  The housing mounts with 4 screws (

ψ

4×25). 

Screw housing to joist through lowest holes in 
each mounting flange, then through the other 
holes. 

Screw  4×25

Joist

 

 

USING SUSPENSION BRAKETS (SOLD 
SEPARATELY) 

1-3.  Sliding suspension brackets available to allow 

for your specific positioning of housing 
anywhere between joists and span up to 24”. 

1-4. Insert 

suspension 

brackets into the channels on 

housing. Make sure tabs face “up” shown. 

Channel

Suspension Bracket
(Sold separately)

Tab Face

 

 

1-5.  Extend suspension brackets to the width of the 

joists. Hold fan in place with the suspension 
brackets tabs wrapping around the bottom of 
joist. 

1-6.  Fasten suspension brackets to joists with nails 

or screws through holes near nails. 

1-7.  Secure suspension brackets together with 

screws. 

Joist

Joist

Bottom of Joist

Screw

 

Fig. A 

Fig. B 