background image

 

 
 
 
 
 
 
 
 
 
 
 

DVPDT02-H2 

DeviceNet Slave Communication Module   

Operation Manual 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

DVP-0205120-02 

Содержание DVPDT02-H2

Страница 1: ...DVPDT02 H2 DeviceNet Slave Communication Module Operation Manual DVP 0205120 02...

Страница 2: ......

Страница 3: ...DVPDT02 H2 can install operate wire and maintain it 3 DO NOT connect input AC power supply to any of the I O terminals otherwise serious damage may occur Check all the wirings again before switching o...

Страница 4: ...Operation Manual 2 5 2 Application Example II 17 6 LED INDICATORS TROUBLE SHOOTING 20 6 1 POWER LED 20 6 2 NS LED 20 6 3 MS LED 20 6 4 NS LED MS LED 21 APPENDIX A DEVICENET OBJECTS DVPDT02 H2 SUPPORTS...

Страница 5: ...etwork configuration tool Re power it to make effect the configuration z I O data is extendable to 200 bytes 1 2 Specifications DeviceNet connection Transmission method CAN Electrical isolation 500VDC...

Страница 6: ...NS MS DR 1 DR 0 IN 0 IN 1 X10 X10 Unit mm inch 2 2 Product Profiles POWER NS MS DR 1 DR 0 IN 0 IN 1 X10 X10 2 3 5 4 6 7 8 9 1 1 I O module connection port 6 NS Network Status indicator 2 Address switc...

Страница 7: ...corresponding switch of x101 to 2 and the corresponding switch of x100 to 6 Note z Please set up the node address when the power is switched off After the setup is completed re power DVPDT02 H2 z Whe...

Страница 8: ...used for the connection to the next DVPDT02 H2 or I O modules of DVP EH2 series PLC MPU 3 Basic Operation 3 1 Connecting DVPDT02 H2 to DVP EH2 Series PLC MPU z Open the connection port on the right h...

Страница 9: ...into special I O module Data read from special I O module 0 Frag 0 XID MAC ID Frag 0 XID MAC ID 1 R R 0 Service Code 0x10 R R 0 Service Code 0x0E 2 Class ID 0x95 Class ID 0x95 3 Instance ID Instance I...

Страница 10: ...nnection path Attribute 3 0 refers to the connection path is not designated Unit byte 3 Get Connection path N A N A Polling path of the parameter value Max connection path 255 bytes 4 Get Descriptor 0...

Страница 11: ...PDT02 H2 has a unique address 2 Re power DVPDT02 H2 F2 Working power in low voltage Check if the power of DVPDT02 H2 and MPU is normal F3 Entering test mode Re power DVPDT02 H2 F4 Bus off Re power DVP...

Страница 12: ...Module Node address Baud rate DVPDNET SL 1 500kbps DVPDT02 H2 2 500kbps 3 Please check and make sure DVP EH2 PLC MPU and DVPDT02 H2 module both operate normally Check also the wiring of the entire net...

Страница 13: ...OM port on the PC to be used to communicate with DVP SV COM1 Address Communication address of DVP SV 01 Baud rate Communication speed between PC and DVP SV 9 600 bps Data Bits 7 Parity Even Parity Sto...

Страница 14: ...the PC and DVP SV is abnormal or there are other programs also using the COM port on the PC After the scan is completed the dialog box will tell you that the scan is completed and the icons and devic...

Страница 15: ...ng One of standard DeviceNet I O transmission methods Supported Bit Strobe Setting One of standard DeviceNet I O transmission methods DVPDT02 H2 does not support this N A COS CC Setting One of standar...

Страница 16: ...Move the slave devices on DeviceNet in the Available Nodes list on the left hand side to the Scan List on the right hand side Select a node and click on Follow the steps to move all the nodes to the s...

Страница 17: ...Click on OK to continue the download 6 Make sure DVP SV is in RUN mode You will then see the MS LED and NS LED on DVPDT02 H2 are steadily on in green color Follow the steps above to configure DeviceN...

Страница 18: ...PDT02 H2 D6037 CR 3 D6038 CR 4 D6039 CR 5 D6040 CR 6 D6041 CR 7 D6042 CR 8 D6043 CR 9 D6044 CR 10 D6045 CR 11 D6046 CR 12 D6047 CR 13 D6048 CR 14 D6049 CR 15 D6050 CR 16 D6051 CR 17 D6052 CR 18 Contro...

Страница 19: ...D102 D6290 CR 106 D103 D6291 CR 107 D104 D6292 CR 108 D105 D6293 CR 109 D106 D6294 CR 110 D107 D6295 CR 111 D108 D6296 CR 112 D109 D6297 CR 113 D110 D6298 CR 114 D111 D6299 CR 115 D112 D6300 CR 116 D...

Страница 20: ...network DeviceNet DVP28SV DVPDNET SL DVPDNET DVP28SV RUN STOP Master DeviceNet network configuration tool STOP RUN 0 1 IN OUT POWER RUN ERROR BAT LOW DVP 20EH 1 Scan the DeviceNet network by DeviceNet...

Страница 21: ...C Operation Manual 19 3 Select Parameter Edit and the Parameter Edit window will appear 4 Set the Input IO Data Length and Output IO Data Length to 200 bytes 5 Click on Download to download the I O da...

Страница 22: ...es 1 Correctly configure it in the master 2 Re download the configured data to the master and set the master to RUN status Green light On DVPDT02 H2 is on line and isnormally connected to the master R...

Страница 23: ...if the network cable is correctly connected to DVPDT02 H2 2 Check if the network power works normally Red ligh On Green light On Dup_MAC_ID test has failed bus off 7 Make sure DVPDT02 H2 has a unique...

Страница 24: ...ype 1 Get Revision UINT 6 Get MaxIdClass UINT 7 Get MaxIdInstance UINT Instance Attribute ID Access rule Name Data type 2 Get NumAvailable UINT 3 Get NumActive UINT Common services Implemented for Ser...

Страница 25: ...D Access rule Name Data type 1 Get State USINT 2 Get InstanceType USINT 3 Get TransportClassTrigger USINT 4 Get ProducedConnectionId UINT 5 Get ConsumedConnectionId UINT 6 Get InitialCommCharacterisit...

Страница 26: ...ion UINT Instance 1 Model code Attribute ID Access rule Name Range Default Explanation 1 Get Parameter value 25136 25136 Model code of DVPDT02 H2 25136 H 6230 2 Get Length of connection path N A N A T...

Страница 27: ...rameter value Max connection path 255 bytes 4 Get Descriptor 0 127 N A The descriptor of parameter 5 Get Data type 1 8 N A The code of data type 6 Get Data length N A N A Number of bytes occupied by t...

Страница 28: ...alue Attribute 1 Unit byte Instance 6 Length of output I O data Attribute ID Access rule Name Range Default Explanation 1 Get Set Parameter value 0 200 32 Unit byte 2 Get Length of connection path N A...