Delta SCARA Robot System User Manual
SCARA CE Series
135
7.2.9 Serial transmission (
RS-232, RS-485)
Standard D-Sub 9P/Female Connector. With controllers such as PC, PLC and HMI, etc. that are
designed with RS-232/485 function, users may carry out the communication with the power control box
controller through such connector to read the Robot data or control the Robot. In addition, controllers
equipped with RS-232/485 functions can also be connected to perform data reading or writing to the
controller.
The location of the RS-232/485 connector is as shown in Figure 7.50.
Figure7. 50 RS-232/485 connector location
In order to ensure that there is no interference for data transmission, please use twisted pair cables with
isolation nets for the connections. The RS-232/485 pin definitions are as shown in Table 7.16.
Table7. 16 Serial transmission (RS-232, RS-485) connector function definition table
Pin
Name
Description
1
RS485+
Driver end data transmission differ end
2
RS232_RX
Driver end data receiver connected to the RS-232 transmitter end of
the PC.
3
RS232_TX
-
Driver end data transmitter connected to the RS-232 receiver end
of the PC.
-
Connected to the RS-232 receiver end of the PC
4
-
Reserved
5
GND
+5V and signal end grounding
6
RS485-
Driver end data transmission differential - end
7
-
Reserved
8
-
Reserved
Содержание DRS40L3SOADF003
Страница 1: ...Delta SCARA Robot System User Manual SCARA CE Series 1 ...
Страница 59: ...Delta SCARA Robot System User Manual SCARA CE Series 59 ...
Страница 64: ...Delta SCARA Robot System User Manual SCARA CE Series 64 Figure4 5 DRS70L series dimensions figure ...
Страница 113: ...Delta SCARA Robot System User Manual SCARA CE Series 113 ...
Страница 115: ...Delta SCARA Robot System User Manual SCARA CE Series 115 ...
Страница 129: ...Delta SCARA Robot System User Manual SCARA CE Series 129 ...