7.2.1 Main circuit power connection
The input power specification of the Delta robot controller is AC 200V to 230V single-phase 50/60 Hz.
Customers need to connect the main power manually and please use cables that comply with VW-1
flame resistance and UL758 wire diameter specifications, as well as cables with the specifications in
Table 7.1 below:
Table7. 1 Main circuit power specification table
Power control box main circuit power cable specifications
Power cable diameter
2.0mm²
Ground cable diameter
10mm²
Installation:
1.
There is a forced interface behind the power control box for customers to install the cables for the
main power circuit; the forced connector specifications are as shown in Table 7.2 below.
Table7. 2 Forced connector specification table
Forced connector specifications
Forced connector allowable cable diameter
14.5mm~19mm
2.
Please insert the power cable of the main circuit to this forced connector, as shown in Figure
7.3 below.
Figure7. 3 Power cable penetrating the forced connector