A X - 3 S e r i e s O p e r a t i o n M a n u a l
7 - 9 4
_7
(2) Execute MC_MoveAbsolute (Position = 180, Velocity = Acceleration = Deceleration = 1000, Direction =
shortest)
When MC_MoveAbsolute.Execute triggers, the system determines the shortest way to reach position 180 is to
move in negative direction (350 – 180 = 170). However, since the process requires velocity to be in reverse,
therefore, more turns are included. The process takes about 2.5 sec.