ASDA-M Chapter 2 Installation
Revision December, 2014
2-5
2.5 Specification of Circuit Breaker and Fuse
Caution: Please use the fuse and circuit breaker that is recognized by UL/CSA.
Servo Drive Model
Circuit breaker
Fuse (Class T)
Operation Mode
General
General
ASD-M-0721-
30A 50A
ASD-M-1521-
70A 140A
NOTE
If the servo drive equips with earth leakage circuit breaker for avoiding
electric leakage, please choose the current sensitivity which is over
200mA and can continue up to 0.1 seconds.
2.6 EMI Filters Selection
Item
Power
Servo Drive Model
EMI Filter Model
FootPrint
1 750W ASD-M-0721-
20TDT1W4D
N
2 1500W ASD-M-1521-
20TDT1W4D
N
EMI Filter Installation
All electronic equipment (including servo drive) generates high or low frequency noise
during operation and interfere the peripheral equipments via conduction or radiation. With
EMI Filter and the correct installation, much interference can be eliminated.
When installing servo drive and EMI Filter, please follow the instructions of the user manual
and make sure it meets the following specification.
1. EN61000-6-4 (2001)
2. EN61800-3 (2004) PDS of category C2
3. A2 (2007) Class A Group 1
Содержание ASD-M-0721 Series
Страница 20: ...ASDA M Chapter 1 Inspection and Model Explanation Revision December 2014 1 7 ASDA M Series Servo Drive top view...
Страница 36: ...ASDA M Chapter 2 Installation Revision December 2014 2 15 Delta Part Number BR1K5W005 3kW 10...
Страница 37: ...Chapter 2 Installation ASDA M 2 16 Revision December 2014 This page is intentionally left blank...
Страница 161: ...Chapter 6 Control Mode of Operation ASDA M 6 36 Revision December 2014 Frequency Domain...
Страница 231: ...Chapter 7 Motion Control ASDA M 7 44 Revision December 2014 This page is intentionally left blank...
Страница 631: ...ASDA M Appendix A Accessories A 10 Revision December 2014 RS 485 Connector Delta Part Number ASD CNIE0B06...
Страница 645: ...Appendix B Maintenance and Inspection ASDA M B 4 Revision December 2014 This page is intentionally left blank...