ASDA-M Chapter 6 Control Mode of Operation
Revision December, 2014
6-3
6.2 Position
Mode
The followings describe the related information and settings of position mode.
6.2.1 Position Command of PT Mode
PT, position command is the pulse input from terminal block. There are three types of
pulse and each type has positive/negative logic which can be set in parameter P1-00.
See as the followings.
P1-00
▲
PTT
External Pulse Input Type
Address: 0100H
0101H
Parameter
Attribute
:
Parameter for individual axis
Related Section:
Section 6.2.1
Operational
Interface
:
Panel / Software
Communication
Default
:
0x2
Control
Mode
:
PT
Unit
:
-
Range
:
0 ~ 1132
Data Size
:
16bit
Format
:
HEX
Settings
:
Pulse
Type
0: AB phase pulse (4x)
1: Clockwise (CW) and Counterclockwise (CCW) pulse
2: Pulse + symbol
Other settings: reserved
Содержание ASD-M-0721 Series
Страница 20: ...ASDA M Chapter 1 Inspection and Model Explanation Revision December 2014 1 7 ASDA M Series Servo Drive top view...
Страница 36: ...ASDA M Chapter 2 Installation Revision December 2014 2 15 Delta Part Number BR1K5W005 3kW 10...
Страница 37: ...Chapter 2 Installation ASDA M 2 16 Revision December 2014 This page is intentionally left blank...
Страница 161: ...Chapter 6 Control Mode of Operation ASDA M 6 36 Revision December 2014 Frequency Domain...
Страница 231: ...Chapter 7 Motion Control ASDA M 7 44 Revision December 2014 This page is intentionally left blank...
Страница 631: ...ASDA M Appendix A Accessories A 10 Revision December 2014 RS 485 Connector Delta Part Number ASD CNIE0B06...
Страница 645: ...Appendix B Maintenance and Inspection ASDA M B 4 Revision December 2014 This page is intentionally left blank...