![Delta ASD-M-0721 Series Скачать руководство пользователя страница 114](http://html1.mh-extra.com/html/delta/asd-m-0721-series/asd-m-0721-series_user-manual_2474520114.webp)
ASDA-M Chapter 5 Trial Operation and Tuning
Revision December, 2014
5-11
5.6 Tuning
Procedure
Estimate the inertia ratio------- JOG mode
1. After completing wiring, when applying to the power, the
servo drive will display:
AL013
2. Press
the
MODE
Key to select the mode of parameter
function.
P0-00
3. Press
the
SHIFT
Key twice to select the mode of parameter
group.
P2-00
4. Press
the
UP
Key to select parameter P2-15.
P2-15
5. Press
the
SET
Key to display parameter value, which is
shown as the content on the right.
21
6. Press
the
SHIFT
Key twice, then press the
UP
Key, the
panel will display
121
. Press the
SET
Key.
121
7. Press
the
UP
Key to select parameter P2-30.
P2-30
8. Press
the
SET
Key to display the parameter value. (See the
figure on the right.)
0
9. Press
the
UP
Key and select the parameter value 1. Then,
press the
SET
Key. The servo drive is in Servo ON status at
the moment.
1
10. The panel will display 0 as shown on the right.
0
11. Press the
MODE
Key first, and press the
DOWN
Key for 12
times to select the value of inertia ratio.
JL
12. The panel displays the current value of inertia ratio (default
value).
1.0
13. Press the
MODE
Key to select the mode of parameter
function.
P2-30
14. Press the
SHIFT
Key twice to select the mode of parameter
group.
P4-00
15. Press the
UP
Key to select parameter P4-05.
P4-05
16. Press the
SET
Key to show the content, which is 20r/min at
JOG speed. Press the
UP
or
DOWN
Key to increase or
decrease the JOG speed. Press the
SHIFT
Key to move to
the next digit of the left.
20
200
17. Set the desired JOG speed and press the
SET
Key which is
shown as the figure on the right.
-Jog-
18. Press the
UP
Key to rotate the motor in forward direction while press the
DOWN
Key
the motor will rotate in reverse direction.
19. Execute JOG operation at low speed first. With the constant speed, if the motor
operates smoothly in forward and reverse direction, users can execute JOG operation
at higher speed.
20. In P4-05, the servo drive cannot display inertia ratio. Please press the
MODE
Key
twice to view the value of inertia ratio. If users desire to execute JOG operation again,
press the
MODE
Key, and then press the
SET
Key twice. Observe the panel display to
see if the load inertia ratio remains at the same value after acceleration and
deceleration.
Содержание ASD-M-0721 Series
Страница 20: ...ASDA M Chapter 1 Inspection and Model Explanation Revision December 2014 1 7 ASDA M Series Servo Drive top view...
Страница 36: ...ASDA M Chapter 2 Installation Revision December 2014 2 15 Delta Part Number BR1K5W005 3kW 10...
Страница 37: ...Chapter 2 Installation ASDA M 2 16 Revision December 2014 This page is intentionally left blank...
Страница 161: ...Chapter 6 Control Mode of Operation ASDA M 6 36 Revision December 2014 Frequency Domain...
Страница 231: ...Chapter 7 Motion Control ASDA M 7 44 Revision December 2014 This page is intentionally left blank...
Страница 631: ...ASDA M Appendix A Accessories A 10 Revision December 2014 RS 485 Connector Delta Part Number ASD CNIE0B06...
Страница 645: ...Appendix B Maintenance and Inspection ASDA M B 4 Revision December 2014 This page is intentionally left blank...