This section will provide an overview of how to use EtherNet/IP to connect to a Delta EtherNet/IP Adapter via the 3rd party
software. Here we take Rockwell’s Software Studio 5000 as an example.
7.1
Architecture
RA EIP Scanner use Ethernet to connect a Delta Adapter; as for the PC, it can connect to the RA Scanner via the
Ethernet/USB.
※
Rockwell Software Studio 5000, ControlLogix, RSLogix are registered trademarks of Rockwell Automation, Inc.
7.2
Create a New Project
Open the Studio 5000 and click the “New Project” under the “Create” section.
Select a PLC. Take 1756-L71 as an example here.
New Project
Select PLC