background image

SENSOR RANGE (d)

The sensor range is the maximum distance at which the user is detected.  The sensor range settings are 3 - 15” in 1” increments.  

The sensor range default value is 9”.

AUTO TIMER (T)

Auto Timer is a safety mode in the event the sensor continually sees a target (i.e. blocked sensor).  In this case, the faucet will stop

after the pre-determined time period expires.

The Auto Timer values are 5, 7, 10, 12, 15, 30, 45, 60, 75, 90 seconds and 2.0, 4.0, 6.0, 8.0, 9.9 minutes (decimal denotes minutes).

The Auto Timer default value is 45 seconds.

RINSE CYCLE (R)

This feature is meant to purge stagnant water from supply lines.  The faucet will turn on after the set amount of hours of inactivity 

and run the set 

Rinse Time (r)

 (see below).

RINSE TIME (r)

This feature is only active if a 

Rinse Cycle (R)

 time is chosen.  The setting determines for how long the faucet will turn on during the

Rinse Cycle (R)

.  The rinse time settings are 10, 20, 30, 40, 50, 60, 90 seconds and 2.0, 2.5, 3.0 minutes (decimal denotes minutes).

BUZZER (b)

The buzzer on the driver board will annunciate twice upon power up indicating product is ready to use.  Buzzer options are ON and

-(OFF), the default setting is ON.

LED (L)

The LED on the sensor will blink indicating low power.  LED options are ON and -(OFF), the default setting is OFF.

METERING MODE (M)

This feature changes the product into a metering faucet; it will run the full set amount of time after the user’s hands are first detected,

and will continue to run after the user removes their hands.

Options are: -(OFF), 7, 8, 9, 10, 11, 12, 13, 14, 15, 18, 24, 30, 40, 50, 60, 90 seconds and 2.0, 2.5, 3.0, 3.5, 4.0 minutes (decimal

denotes minutes).  The default setting is -(OFF).  

Note: 

Auto Timer (T)

 is disabled when the feature is turned on.

Function

Function

Setting

MODE

TOGGLE

BATTERY STRENGTH INDICATOR

To check the battery strength:
 

Press and hold MODE (yellow pushbutton on left hand side).  After 5 seconds the battery strength will be displayed:

 

●  FUL  -  Healthy

 

●  MID  -  Average

 

●  Lo_  -  Low Average

 

●  bAd  -  Replace Batteries (buzzer will annunciate and LED will blink if activated - if these features are turned on).

                              Faucet will disable itself if batteries are not replaced.

If you have any questions about the installation of this product or need help troubleshooting this product, please call Delta

Commercial Technical Services at 

1-800-387-8277

 (Canada) or 

1-877-509-2680

 (U.S.A.)

.

To adjust settings, press and hold MODE (yellow pushbutton on left

hand side) until the Function symbol appears.  Once in Adjustment

Mode, keep pressing MODE until desired Function is reached (see

Quick Reference Table).  To change Function Setting, press and

release TOGGLE (white pushbutton on right hand side) until desired

Function Setting is reached (see Quick Reference Table).

Note:

 Will leave Adjustment Mode after 5 seconds.

Page 6

 

209489   Rev. C

w w w . s p e c s e l e c t . c o m

Содержание 150 T3 Series

Страница 1: ...aximum intended pressure setting 061256A 36 Cable Extension RP30523 Braided Hose 060683A 24VAC to 6VDC Converter 063245A 2 2 GPM 8 3 L min 063139A 0 5 GPM 1 9 L min 063140A 1 5 GPM 5 7 L min Adapter w...

Страница 2: ...re converter by using a flat screwdriver damage may result Turn on power supply for the transformer STEP 6 PREPARE SINK AREA Before connecting the spout cable clean off counter and remove all objects...

Страница 3: ...Depending on installation the cable bushings included may be replaced by installer supplied 1 2 conduit Rough in box as per Figure 8 The transformer is to be installed in an adjacent accessible space...

Страница 4: ...w in the direction of water flow See Fig 10 Feed sensor wire from spout into control box and then connect to the driver board Connect red solenoid wire from the driver board to marked solenoid termina...

Страница 5: ...le If this feature is turned to an xx hour value the faucet will turn on itself after this set time from last use OFF 6 12 18 24 30 36 42 48 hours r Rinse Time This is the amount of time you want the...

Страница 6: ...changes the product into a metering faucet it will run the full set amount of time after the user s hands are first detected and will continue to run after the user removes their hands Options are OF...

Страница 7: ...r 060683A if required The faucet stops working No water flow Check the function of the solenoid Step 3 The solenoid should click when activated Clean as required Correct as required If there is a clic...

Страница 8: ...you This warranty gives you specific legal rights and you may also have other rights which vary from state to state This warranty is for commercial products only from Delta Faucet Company and Delta F...

Отзывы: