background image

FOR SURFACE MOUNT HOUSING: CONTROL BOX #0

STEP 1. FAUCET INSTALLATION

 

STEP 2. BATTERY BOX INSTALLATION

Mount battery box to wall under sink using the 4 supplied screws and anchors.  Use

1/4” drill for wall anchors.  

Be sure to install the box within the dimensions provided

so the hose and spout cable will reach connections at faucet and battery box.

Refer to illustration (Fig. 2).

STEP 3. FLUSH SYSTEM

To flush supply line, assemble these components as shown (Fig. 3) and run water for 1

minute.  Shut off water supply.  Attach aerator.  

NOTE:

 Do not connect supply to the

solenoid inlet until line is flushed directly out spout.

STEP 4. CONNECT WATER SUPPLY

Disassemble the components, reassemble the ones shown here (Fig. 4) supply line

and adaptor to the bottom fitting on box, braided hose to the top fitting on box.  Use

plumber tape where indicated on adaptor.  Turn on water supply.  

DO NOT SOLDER

CONNECTIONS!

STEP 5. POWER UP

Unscrew the battery box lid screws (2). Install 4 “Alkaline C” batteries in holder or snap

the battery clip directly to the optional 24 VAC converter.

BATTERY VERSION

  

Install four “Alkaline C” batteries provided into the battery holder.

After the batteries are installed, make the sensor connection on the driver board neatly

inside the battery box.  Connect battery clip to battery pack.  Two beeps indicate product

is ready to use.  Use caution not to damage wires or components on electronic driver

board.  See Fig. 5.  Secure lid using screws.  Do not use 9V battery.

HARDWIRE VERSION

  

Install CSA and/or UL approved Class 2 transformer or equiv-

alent in a convenient location or in a pipe chase.  

(Do NOT install the transformer

inside the control box.)

  With the power off, bring the 24 VAC supply wires to the box.

Connect the 24 VAC supply to the 060683A conversion kit.  Connect the battery snap

of the hardwire converter to the driver board battery clip.  Ensure snap does not touch

any conductive metal surface, then make the sensor connection on the control module

neatly inside the battery box.  Do not remove battery snap from hardwire converter by

using a flat screwdriver, damage may result.  Turn on power supply for the transformer.  

STEP 6. PREPARE SINK AREA

Before connecting the spout cable – clean off counter and remove all objects

from the sink.

STEP 7. TIE SPOUT CABLE

Attach spout cable to box connector. Use tie wraps to secure spout cable to spout hose.

Your faucet is now ready for use (Fig. 2).

STEP 8. TEST FOR OPERATION

Test for operation.  If faucet leaks from spout outlet: SHUT OFF WATER SUPPLIES.

Replace solenoid (2).

If faucet exhibits very low flow: A) Remove and clean spray outlet, or B) SHUT OFF

WATER SUPPLY.  Clean or replace screen assembly (2). If unit does not work properly;

see Troubleshooting Guide on page 6.

INSTALLATION AND SET UP INSTRUCTIONS

Installation should be in accordance with local plumbing and electrical codes.

FLUSH ALL PIPES THOROUGHLY BEFORE INSTALLATION. 

 

7" (178 mm)

Max.

 

13" (331 mm) Max.

Tie Wraps

NOTE: 

Entire connection can be placed

inside battery box if desired.

 

 

 

3/8" O.D.

Copper

Inlet 

Bypass

Adapter

Ferrule

Nut

Spout

Hose

Plumber

Tape

Fig. 2

Fig. 3

Fig. 4

063131A

3/8” Comp

Connect Nut

and Ferrile

Connect 20” braided hose to spout inlet.  Clean deck/sink surface where faucet will be

mounted.  Mount faucet to sink using nut(s) and washer(s) provided.  Installation of the

single hole deck gasket (060564A) between the turret base and mounting surface is the

recommended assembly practice.  Ensure that gasket is sitting flat on the deck and the

turret is centered on the gasket.  Use the same procedure for installation of optional 4”

or 8” deck plate package (060546A or 060547A).  Mount the faucet to the sink using

nut(s) and washer(s) provided.  Do not overtighten the nut (RP6087) or reposition the

turret once installed, otherwise damage to the gasket may result.  Cutting or trimming 

of the gasket is not recommended.  

NOTE: If the gasket is trimmed or not installed,

then use clear silicone sealant between the faucet and lavatory to prevent water

from leaking beneath lavatory.

 

Fig. 5

Trap

jacket of

cable in

hole for

strain

relief.

NOTE: 

Always make

sure driver board is in

place before inserting

the battery pack.  Use

caution not to pinch

wires or damage

components on the

electronic driver board.

1

2

Page 2

 

209489   Rev. C

w w w . s p e c s e l e c t . c o m

Содержание 150 T3 Series

Страница 1: ...aximum intended pressure setting 061256A 36 Cable Extension RP30523 Braided Hose 060683A 24VAC to 6VDC Converter 063245A 2 2 GPM 8 3 L min 063139A 0 5 GPM 1 9 L min 063140A 1 5 GPM 5 7 L min Adapter w...

Страница 2: ...re converter by using a flat screwdriver damage may result Turn on power supply for the transformer STEP 6 PREPARE SINK AREA Before connecting the spout cable clean off counter and remove all objects...

Страница 3: ...Depending on installation the cable bushings included may be replaced by installer supplied 1 2 conduit Rough in box as per Figure 8 The transformer is to be installed in an adjacent accessible space...

Страница 4: ...w in the direction of water flow See Fig 10 Feed sensor wire from spout into control box and then connect to the driver board Connect red solenoid wire from the driver board to marked solenoid termina...

Страница 5: ...le If this feature is turned to an xx hour value the faucet will turn on itself after this set time from last use OFF 6 12 18 24 30 36 42 48 hours r Rinse Time This is the amount of time you want the...

Страница 6: ...changes the product into a metering faucet it will run the full set amount of time after the user s hands are first detected and will continue to run after the user removes their hands Options are OF...

Страница 7: ...r 060683A if required The faucet stops working No water flow Check the function of the solenoid Step 3 The solenoid should click when activated Clean as required Correct as required If there is a clic...

Страница 8: ...you This warranty gives you specific legal rights and you may also have other rights which vary from state to state This warranty is for commercial products only from Delta Faucet Company and Delta F...

Отзывы: