![Delta Tau Geo Brick Скачать руководство пользователя страница 146](http://html1.mh-extra.com/html/delta-tau/geo-brick/geo-brick_user-manual_2478499146.webp)
Geo Brick Drive User Manual
Pinouts and Software Setup
146
Setting up the Analog (DAC) Outputs
Differential DAC Output Signal
Single Ended DAC Output Signal
2
3
4
5
9
8
7
6
1
AGND
Analog
Device
DAC+
DAC-
2
3
4
5
9
8
7
6
1
AGND
Analog
Device
DAC+
The analog outputs on X9 through X12 are (12-bit) filtered PWM signals, therefore a PWM frequency in
the range of 30-40 KHz and a PWM deadtime of zero are suggested for a good quality analog output
signal (minimized ripple). A fully populated Brick can have one of three gates generating the clocks:
Servo IC 0 (I7000’s)
Servo IC 1 (I7100’s)
MACRO IC 0 (I6800’s)
I19 specifies which gate is the clock source master. I19 is equal to 7007 by default indicating that Servo
IC 0 is the master gate. However, the analog outputs on X9 through X12 are generated out of Servo IC1.
The relationship between the PWM clock frequency of Servo IC 1 (recipient) and the master gate
(generator), typically Servo IC 0, should always be respected in such a way that:
Where n is an integer
Examples:
With Servo IC 0 sourcing the clock at its default settings (4.5 KHz PWM), the following are suggested
Servo IC 1 clock settings which would provide a good analog output signal:
Servo IC 0
Clock Settings
Resulting
Frequencies KHz
Servo IC 1
Clock Settings
Resulting
Frequencies KHz
I7000=6527
I7001=0
I7002=3
I10=3713991
PWM
PHASE
SERVO
4.5
9.0
2.25
I7100=816
I7101=7
I7102=3
I7104=0
PWM
PHASE
SERVO
PWM
Deadtime
36
9
2.25
0
Note that n=8 in this case