Yaskawa Incremental Encoder Alarm Codes
Yaskawa Incremental encoder Alarm Registers
Channel 1 Y:$78B22,8,8 Channel 5 Y:$78B32,8,8
Channel 2 Y:$78B26,8,8 Channel 6 Y:$78B36,8,8
Channel 3 Y:$78B2A,8,8 Channel 7 Y:$78B3A,8,8
Channel 4 Y:$78B2E,8,8 Channel 8 Y:$78B3E,8,8
Bit# Error Name
Type
Alarm
Type
Clear
Action
Notes
8
Fixed at “1”
-
-
-
9
Encoder Error
Alarm
Session
Flag
Power
cycle
Encoder Error
10
Fixed at “0”
-
-
-
11
Position Error
Alarm
Session
Flag
Power
cycle
Possible error in position or Hall
sensor
12
Fixed at “0”
-
-
-
13
Fixed at “0”
-
-
-
14
Origin not passed
flag
Warning
-
-
The origin has not been passed in this
session yet
15
Fixed at “0”
Set at zero