background image

-      - 

TABLE OF CONTENTS 

 

1. GENERAL CHARACTERISTICS ............................................................................................................................. 5

 

2. DESCRIPTION OF THE FUNCTIONS .................................................................................................................... 6

 

3. MENU ............................................................................................................................................................................ 9

 

4. PROBES AND MEASUREMENTS .......................................................................................................................... 10

 

4.1

 

PP471

 MODULE FOR PRESSURE MEASUREMENT

 .................................................................................................. 10

 

4.2

 

Pt100

 TEMPERATURE PROBE

............................................................................................................................... 11

 

4.2.1 Temperature measurement ............................................................................................................................. 11

 

4.2.2 Connecting the TP47 connector ..................................................................................................................... 11

 

4.2.3 Direct connection of 4 wire Pt100 sensors ..................................................................................................... 13

 

5. WARNINGS ................................................................................................................................................................ 14

 

6. INSTRUMENT SIGNALS AND FAULTS............................................................................................................... 15

 

7. INSTRUMENT STORAGE ....................................................................................................................................... 16

 

8. LOW BATTERY WARNING AND BATTERY REPLACEMENT ..................................................................... 17

 

8.1

 

W

ARNING ABOUT BATTERY USE

 ......................................................................................................................... 17

 

9. NOTES ABOUT WORKING AND OPERATIVE SAFETY ................................................................................. 18

 

10. TECHNICAL CHARACTERISTICS .................................................................................................................... 19

 

10.1

  

T

ECHNICAL INFORMATION ON THE 

M

ANOMETER 

 

T

HERMOMETER

 ................................................................ 19

 

10.2

  

O

N LINE INSTRUMENT PROBES AND MODULES TECHNICAL DATA

 .................................................................... 20

 

10.2.1 Pressure measurement by module PP471 ..................................................................................................... 20

 

10.2.2 Temperature probes Pt100 using SICRAM module ..................................................................................... 21

 

10.2.3  - 4 wire Pt100 Probes .................................................................................................................................. 21

 

11. ORDER CODES ....................................................................................................................................................... 22

 

11.1

 

P

ROBES COMPLETE WITH 

SICRAM

 MODULE

 ................................................................................................... 22

 

11.2

 

T

EMPERATURE PROBES WITHOUT 

SICRAM

 MODULE

 ...................................................................................... 22

 

 

 

 
 

 
 
 
 

 

Содержание HD2304.0

Страница 1: ...n this manual and the instrument that you have purchased We cannot entirely exclude errors in the manual for which we apologize The data figures and descriptions contained in this manual cannot be leg...

Страница 2: ...2 Manometer Thermometer HD2304 0...

Страница 3: ...tion in the menu increases the current value 8 UNIT MENU key it allows selection of the unit of measurement when pressed together with the DATA key it allows to open the menu 9 ZERO performs the zero...

Страница 4: ...FAULTS 15 7 INSTRUMENT STORAGE 16 8 LOW BATTERY WARNING AND BATTERY REPLACEMENT 17 8 1 WARNING ABOUT BATTERY USE 17 9 NOTES ABOUT WORKING AND OPERATIVE SAFETY 18 10 TECHNICAL CHARACTERISTICS 19 10 1...

Страница 5: ...bes The probes are fitted with the SICRAM automatic detection module with the factory calibration settings already being memorized inside The units of measurement for the measurable quantities are Pa...

Страница 6: ...on can be disabled by simultaneously pressing this key and the HOLD key when turning the instrument on During turning on should no probes be connected the NO_PRBE_SER_NUM message is displayed in the l...

Страница 7: ...trument is off the previously memorized data are cleared Upon turning on the instrument automatically starts memorizing the MAX MIN and AVG values To reset the previous values and start with a new mea...

Страница 8: ...nnected to the instrument s input see chapter 3 the menu is opened by pressing simultaneously DATA UNIT the first item of the instrument programming menu will appear use the and arrows respectively lo...

Страница 9: ...te are displayed alternately in the secondary line temperature probes Pt100 complete with SICRAM module the Auto message is displayed in the central part of the display direct 4 wire Pt100 temperature...

Страница 10: ...nts The threaded connection is protected by a plastic cap Put it back after use as it protects the pressure cell from foreign bodies IMPORTANT Ensure the probe s bottom scale is higher than the pressu...

Страница 11: ...probe NOTE when measuring the temperature on frozen blocks it is convenient to use a mechanical tool to bore a cavity in which to insert the tip probe In order to perform a correct contact measuremen...

Страница 12: ...00 3 wires Pt1000 Ni1000 Not Used Caution Before welding pass the probe cable through the fairlead and gasket 6 Weld the wires as shown in the table Sensor Board connection Jumper to close Pt100 4 wir...

Страница 13: ...ve to be soldered as indicated in the figure on the left In order to use this type of probe it is necessary to set up the menu item Probe Type as described at page 9 The P100 probe is recognized upon...

Страница 14: ...erform It has high levels of uncertainty and depends on the ability of the operator 9 Temperature measurements on non metal surfaces usually require a great deal of time due to the low heat conductivi...

Страница 15: ...ecific instrument SYS ERR Instrument management program error Contact the instrument s supplier and communicate the numeric code reported by the display CAL LOST Program error it appears after turning...

Страница 16: ...n places where humidity is high the instrument may be exposed to direct sunlight the instrument may be exposed to a source of high temperature the instrument may be exposed to strong vibrations the in...

Страница 17: ...strument back on To replace the batteries proceed as follows 1 switch the instrument off 2 unscrew the battery cover counter clockwise 3 replace the batteries 3 1 5V alkaline batteries type AA 4 screw...

Страница 18: ...safety of the instrument can only be guaranteed under the environmental and electrical operating conditions that are in specified in chapter TECHNICAL CHARACTERISTICS Do not use or store the product...

Страница 19: ...y 200 hours with 1800mAh alkaline batteries Power absorbed with instrument off 20 A Connections Input for probes 8 pole male DIN45326 connector Unit of Measurement Pa hPa kPa mbar bar atm mmHg mmH2O k...

Страница 20: ...80 C BSP 400 mbar 800 mbar 900 mbar 0 1 mbar TP704 400MBGI 0 25 FSO 10 80 C BSP 500 mbar 1500 mbar 1800 mbar 0 1 mbar TP705 500MBD 0 25 FSO 0 60 C Tube 5mm 600 mbar 1200 mbar 1500 mbar 0 1 mbar TP704...

Страница 21: ...400 C TP474C 0 Contact 50 C 400 C 0 3 C 50 C 350 C 0 4 C 350 C 400 C TP475A 0 Air 50 C 250 C 0 3 C 50 C 250 C TP472I 5 Immersion 50 C 400 C 0 3 C 50 C 350 C 0 4 C 350 C 400 C TP472I 10 Immersion 50 C...

Страница 22: ...TP472I 0 Pt100 sensor immersion probe Stem 3 mm length 230 mm Cable length 2 metres TP473P 0 Pt100 sensor penetration probe Stem 4 mm length 150 mm Cable length 2 metres TP474C 0 Pt100 sensor contact...

Страница 23: ...i campioni internazionali e nazionali delle unit del SIT garantita da una catena di riferibilit ininterrotta che ha origine dalla taratura dei campioni di laboratorio presso l Istituto Primario Nazion...

Страница 24: ...ectronic devices with the following symbol cannot be disposed in the public dumps According to the Directive UE 2002 96 EC the European users of electric and electronic devices are allowed to give bac...

Отзывы: