INSTALLATION 

 

ISO AMP 

4 / 7 

DELTA ELEKTRONIKA B.V. 

rev. Febr. 2021 

 

 

4

 

INSTALLATION 

 

Warning!

 carefully read the chapter "Safety Instructions" in 

this manual before connecting or operating the unit! 

4.1

 

HUMIDITY & CONDENSATION 

 

During normal operation, humidity will not harm the interface, 
provided the air is not aggressive. The heat normally 
produced in the power supply will keep it dry. 

 

Avoid condensation inside the interface, to prevent break-
down. Condensation can occur during a period the interface 
or power supply has been switched off (or operating at no 
load) and the ambient temperature is increasing. Always allow 
the interface to dry before switching it on again. 

4.2

 

TEMPERATURE & COOLING 

 

The storage temperature range is 

–40 to +85 °C. 

 

The operating temperature range is 

–20 to +50 °C. 

 

Please note: a lower temperature extends the lifetime of the 
interface. 

4.3

 

INSTALLING THE ISO AMP MODULE  

 

Mount the ISO AMP MODULE using the wall or rail mounting 
adapter. 

 

Connect the power supply to the ISO AMP MODULE with the 
supplied 15 pole cable. 

 

Connect a 15-30 V DC supply voltage to the 2-pole 
connector. + and - are indicated on the module, see fig 4 -1. 

 

Finally connect your programming source to the connector 
marked ‘TO PROG. SOURCE’, see fig 4 -1 and fig 4 - 2. 

 

For use with other units than Delta Elektronika power 
supplies, make sure to connect pin 1 to pin 8 on the 
connector 'To Power Supply', see fig 4 - 3. 

4.4

 

WALL OR RACK MOUNTING 

 

Use the included mounting plate, see fig 4 - 4, for attaching 
the module to a rack or a wall. 

 

No special cooling is required, the module does not heat up 
more than 10 degrees above ambient temperature. 

4.5

 

INSTALLING THE ISO AMP CARD  

 

The ISO AMP CARD should always be factory installed and 
calibrated together with the power supply. 

 

Contact factory for more information. 

 

For operation, connect a 15 pole cable to the ISO AMP 
connector at the rear side of the power supply.  

 

For the following steps, please advice the operating manual of 
the power supply for exact details. 

 

 

fig 4 - 2 

To programming source. 

 
 

 

 

fig 4 - 1 

Front panel connections. 

 

 

 

fig 4 - 3 

To power supply. 

 

 

fig 4 - 4 

A wall mounting adapter is standard supplied with 

the ISO AMP Module 

Содержание ISO AMP Series

Страница 1: ...413656 ISO AMP series ISO AMP CARD ISO AMP MODULE PRODUCT MANUAL Contents 1 Safety Instructions 2 Sicherheitshinweise 3 Installation 4 Operation Calibration 5 EU Declaration of Conformity 6 UK Declar...

Страница 2: ...ent replacement is allowed by non Delta Elektronika qualified personnel Never replace components with the power cable connected To avoid injuries always disconnect power remove external voltage source...

Страница 3: ...ttet Reparaturen am Ger t d rfen nur durch eine Delta Elektronika Serviceeinrichtung durchgef hrt werden 3 6 Entfernung von Sicherheits Abdeckungen Sicherheitsabdeckung en werden verwendet um potenzie...

Страница 4: ...pply to the ISO AMP MODULE with the supplied 15 pole cable Connect a 15 30 V DC supply voltage to the 2 pole connector and are indicated on the module see fig 4 1 Finally connect your programming sour...

Страница 5: ...an extra full scale error of 0 1 Table 5 2 shows the full scale calibration trimmers Warning before proceeding with the calibration of the ISO AMP make sure that your measuring equipment has the corre...

Страница 6: ...isted in the official Journal of the European Communities EN 61000 6 3 2007 Generic Emissions residential light industrial A1 2011 EN 61000 3 2 2014 Power Harmonics EN 61000 3 3 2013 Voltage fluctuati...

Страница 7: ...al commercial and light industrial environments BS EN 61000 6 2 2005 Electromagnetic compatibility EMC Generic standards Immunity standard for industrial environments BS EN 61000 6 1 2007 Electromagne...

Отзывы: