SAFETY INSTRUCTIONS 

 

ISO AMP 

2 / 7 

DELTA ELEKTRONIKA B.V. 

rev. Febr. 2021 

 

This marking shown on the product, its packing or its literature indicates that it should not be disposed with 
other wastes at the end of its working life, but should be collected separately to recycle it responsibly to 
promote the sustainable reuse of material resources.  

2

 

SAFETY INSTRUCTIONS 

– ISO AMP - series 

2.1

 

Caution 

The following safety precautions must be observed during all phases of operation, service and repair of this equipment. 
Failure to comply with the safety precautions or warnings in this document violates safety standards of design, 
manufacture and intended use of this equipment and may impair the built-in protections. Delta Elektronika shall not be 
liable for user’s failure to comply with these requirements. 

2.2

 

Installation Category 

The Delta Elektronika interfaces have been evaluated to installation category II (Over voltage category II). 

2.3

 

Grounding 

This product is a safety Class 1 equipment. For safety isolation both the metal assembly terminals next to the 15p 
connector must be firmly connected to the metal chassis of a grounded Delta Elektronika power supply. Any interruption 
of the protective ground conductor, or disconnection of the metal terminals will cause a potential shock hazard that might 
cause personal injury. 
 
For grounding of the power supply, see the specific power supply operating manual for detailed safety instructions. 

2.4

 

Live Circuits 

Operating personnel should not remove the unit covers. No internal adjustment or component replacement is allowed by 
non Delta Elektronika qualified personnel. Never replace components with the power cable connected. To avoid injuries, 
always disconnect power, remove external voltage sources and discharge circuits before touching components. 

2.5

 

Parts Substitutions & Modifications 

Parts substitutions and modifications are allowed by authorized Delta Elektronika service personnel only. For repairs the 
unit must be returned to a Delta Elektronika service facility. 

2.6

 

Removal of (safety) covers   

Safety cover(s) are used to cover potentially hazardous voltages. 
Observe the following when removing safety cover(s):  

 

Switch off the unit and disconnect the unit from the AC mains supply and from the DC power application. 

 

Wait for 5 minutes to allow internal capacitors to discharge, then unscrew and remove the cover(s). 

 

Always place the cover(s) back before connecting the unit to the mains supply again. 

2.7

 

Environmental Conditions 

 

The Delta Elektronika power supplies safety approval applies to the following operating conditions: 

 

Usage 

 

 

: Indoor use only.  

  

 

 

 

  

Warning!

 Not intended to be used in the presence of children or animals! 

 

Ambient temperature 

 

: -20 to 50 °C. 

 

Maximum relative humidity 

: 95%, non condensing, up to 40 °C, 75%, non condensing, up to 50 °C. 

 

Altitude 

 

 

: Do not use above 2000 m sea level.  

  

 

 

 

  

Warning!

 Electrical Creepage & Clearance not valid for higher altitudes! 

 

Pollution degree   

 

: 2 

2.8

 

Symbols & markings 

WEEE  (Waste Electrical & Electronic Equipment) 

1.1

 

Correct Disposal of this Product 

Applicable in the European Union. 

Caution risk of electrical Shock. 

Instruction manual symbol. The instrument will be marked with this symbol when it is 
necessary fort he user to refer to the instruction manual.  
 
Protective ground conductor terminal.  

Off (supply).  

On (supply). 

Содержание ISO AMP Series

Страница 1: ...413656 ISO AMP series ISO AMP CARD ISO AMP MODULE PRODUCT MANUAL Contents 1 Safety Instructions 2 Sicherheitshinweise 3 Installation 4 Operation Calibration 5 EU Declaration of Conformity 6 UK Declar...

Страница 2: ...ent replacement is allowed by non Delta Elektronika qualified personnel Never replace components with the power cable connected To avoid injuries always disconnect power remove external voltage source...

Страница 3: ...ttet Reparaturen am Ger t d rfen nur durch eine Delta Elektronika Serviceeinrichtung durchgef hrt werden 3 6 Entfernung von Sicherheits Abdeckungen Sicherheitsabdeckung en werden verwendet um potenzie...

Страница 4: ...pply to the ISO AMP MODULE with the supplied 15 pole cable Connect a 15 30 V DC supply voltage to the 2 pole connector and are indicated on the module see fig 4 1 Finally connect your programming sour...

Страница 5: ...an extra full scale error of 0 1 Table 5 2 shows the full scale calibration trimmers Warning before proceeding with the calibration of the ISO AMP make sure that your measuring equipment has the corre...

Страница 6: ...isted in the official Journal of the European Communities EN 61000 6 3 2007 Generic Emissions residential light industrial A1 2011 EN 61000 3 2 2014 Power Harmonics EN 61000 3 3 2013 Voltage fluctuati...

Страница 7: ...al commercial and light industrial environments BS EN 61000 6 2 2005 Electromagnetic compatibility EMC Generic standards Immunity standard for industrial environments BS EN 61000 6 1 2007 Electromagne...