SERIES
3-PHASE FILTERS
L
L
G
Cx1
N
T
E
S
I
R
L
R2
Cy
Cx2
A
R1
T' D
S'
O
R' L
G'
ELECTRICAL SCHEMATIC
1. Applications: Electric equipment, UPS, machine tool,
copy machine, automation equipment, robot, AC motor drive
2. Voltage rating: 480VAC
3. Operating frequency: 50/60Hz
INTRODUCTIONS
MINIMUM INSERTION LOSS IN dB
COMMON MODE(L-G)IN 50 OHM SYSTEM
FREQUENCY-MHz
PART NO.
07TDVST2
16TDVST2
30TDVST2
42TDVST2
55TDVST2
75TDVST2
100TDVST2
.15
50
45
45
50
50
40
35
.50
70
55
50
60
50
55
50
50
55
50
50
65
1.0
50
45
45
35
30
45
50
5.0
25
25
10
40
25
30
30
30
18
15
15
10
10
20
20
30
7
7
DIFFERENTIAL MODE(L-L)IN 50 OHM SYSTEM
07TDVST2
16TDVST2
30TDVST2
42TDVST2
55TDVST2
75TDVST2
100TDVST2
40
30
35
45
45
45
40
45
35
45
45
50
60
55
45
35
50
45
70
50
55
40
35
40
45
50
40
50
40
30
45
35
40
40
50
5
7
20
25
40
30
20
DIMENSIONS IN INCHES/mm
282.0
11.102
3.425
92.0
87.0
3.622
2.835
1.654
6.378
9.528
242.0
222.0
8.740
162.0
2.047
52.0
47.0
3.425
87.0
1.850
42.0
72.0
A
B
C
295.0
312.0
12.283
11.614
2.362
6.5
60.0
0.256
7.087
0.787
7.559
10.709
272.0
252.0
10.039
255.0
235.0
9.921
192.0
9.252
180.0
1.181
30.0
25.0
0.984
20.0
5.4
0.213
D
E
F
G
07TDVST2
PART NO.
16TDVST2
30TDVST2
42TDVST2
55TDVST2
75TDVST2
100TDVST2
8.740
222.0
9.252
235.0
9.921
252.0
9.528
9.449
3.543
5.906
10.63
10.039
2.559
242.0
240.0
90.0
150.0
270.0
255.0
653.0
3.622
92.0
5.394
137.0
10.709
272.0
10.039
255.0
SERIES DIMENSIONS
MECHANICAL CONSTRUCTION
9-8
G
B
M
A
X
.
D MAX.
15.0 2.0
M6X1.0
A MAX.
C
M
A
X
.
INCH
UNIT:
mm
1.0
0.039
E
1
.0
0
.0
3
9
F
0.591 0.787
TH
R
E
E-
P
H
A
SE
F
IL
TE
R
S
07TDVST2
6.6
0.60
0.60
1.70
2.52
1.00
2.2
PART NO.
Cx1(uF)
L(mH)
Cy(uF)
1.0
0.68
R1(M ) R2(M )
Cx2(uF)
2.2
16TDVST2
30TDVST2
42TDVST2
55TDVST2
75TDVST2
100TDVST2
4.4
4.4
6.6
0.45
0.30
1.5
COMPONENTS