DVP15MC11T Operation Manual
11
1
11.3.14
DMC_SetTorque
FB/FC
Explanation
Applicable model
FB
DMC_SetTorque sets the torque of the servo axis. The servo axis will
work under the torque mode when the instruction is executed.
DVP15MC11T
Input Parameters
Parameter
name
Function
Data type
Valid range
(Default)
Validation timing
Axis
Specify the number of the axis
which is to be controlled.
USINT
1~32
(The variable
value must be set)
When
Enable
changes to TRUE
Enable
The instruction is executed when
Enable
changes from FALSE to
TRUE.
BOOL
TRUE or FALSE
(FALSE)
-
TargetTorque
Specify the value of the target
torque.
The torque is expressed with the
permillage of the rated torque of
the servo axis. For example, the
setting value 30 indicates that the
set torque is 30‰ of the rated
torque of the servo axis. While
Enable
is TRUE, modifying the
parameter value will change the
torque directly.
INT
Negative number,
positive number
and 0
(0)
When
Enable
changes to TRUE
Notes:
1. If the torque value is a positive number, the effection that the servo produces works in the positive
direction. If the torque value is a negative number, the effection that the servo produces works in the
negative direction.
2. When
Enable
is TRUE, the instruction is always valid and the torque changes accordingly as the
torque value is modified. The instruction cannot be aborted by other instructions excluding MC_Stop.
When
Enable
of the instruction is reset to FALSE, the instruction execution stops and other
instruction can be executed.
Output Parameters
Parameter name
Function
Data type
Valid range
InTorque
TRUE when the target torque is reached.
BOOL
TRUE / FALSE
Busy
TRUE when the instruction is being executed.
BOOL
TRUE / FALSE
Active
TRUE when the axis is being controlled.
BOOL
TRUE / FALSE
CommandAborted
TRUE when the instruction is aborted.
BOOL
TRUE / FALSE
Error
TRUE when an error occurs in execution of the
instruction.
BOOL
TRUE / FALSE
ErrorID
Contains the error code when an error occurs.
WORD
DMC_Set Torque
Ax is
InTorque
DMC_S etTorque_instan ce
Enable
TargetTorque
Busy
Act iv e
CommandAborted
Erro r
ErrorI D
11-90
Содержание DVP15MC11T
Страница 9: ...Memo viii...
Страница 15: ...DVP15MC11T Operation Manual _2 MEMO 2 4...
Страница 71: ...DVP15MC11T Operation Manual _7 Memo 7 10...
Страница 81: ...DVP15MC11T Operation Manual _8 Timing Chart F_TRG_CLK F_TRG_Q 8 10...
Страница 158: ...Chapter 8 Logic Instructions 8_ The program 1 ASIN EN ENO In Out ASIN_EN ASIN_In Out1 8 87...
Страница 213: ...DVP15MC11T Operation Manual _8 The program 1 LIMIT EN ENO MN Out MX In LIMIT_EN LIMIT_MN LIMIT_MX LIMIT_In Out1 8 142...
Страница 216: ...Chapter 8 Logic Instructions 8_ The program 1 BAND EN ENO MN Out MX In BAND_EN BAND_MN BAND_MX BAND_In Out1 8 145...
Страница 249: ...DVP15MC11T Operation Manual _8 8 178...
Страница 285: ...DVP15MC11T Operation Manual _8 Memo 8 214...
Страница 286: ...9 Chapter 9 Introductions of Axis Parameters Table of Contents 9 1 Description of Axis Parameters 9 2 9 1...
Страница 323: ...DVP15MC11T Operation Manual 10 MEMO 10 34...
Страница 549: ...DVP15MC11T Operation Manual A MEMO A 16...
Страница 571: ...DVP15MC11T Operation Manual C Memo C 10...
Страница 572: ...D Appendix D Explanation of Homing Modes Table of Contents D 1 Explanation of Homing Modes D 2 D 1...