DVPDU-01

 Digital Setup Display 

                                                     

Instruction Sheet

 

1  

WARNING 

 

 

Please power down the MPU of the 
PLC prior to install the DU-01, which 
is connected via a high-density 
connector.  Also please read the 
figures on the right for operation 
correctly to prevent damage.

 

 

 

2  

INTRODUCTION 

 

DU-01 Digital Setup Display has two operation modes, TS-01 and 
TC-01.  The mode selection switch locates at the back of the 
DU-01.  Factory setting is TS-01 mode.  The current operation 
mode will be displayed every time when power up. 

TS-01

 

TC-01

 

Back of the DU-01 

1. In 

TS-01

 mode, DU-01 (specified as TS-01 hereof) has the following functions: 

• 

Read/Write both the internal devices of PLC (e.g. perpetual calendar, bit devices (X, Y, M, S) 
and word devices

 

(T, C, D)) and the Control Register (CR) inside the extension units. 

• 

Support the read/write 32-bit data register.     

• 

Set Start-up display and power save mode. 

• 

Monitor the devices. 

• 

If connect the accessory cable to ES-series without perpetual calendar, the Time Display will 
start from 00-00-00 calculated by the microprocessor of DU-01 (timing error may occur). 

• 

Give RUN-STOP command to PLC. 

2. In 

TC-01

 mode, DU-01 (specified as TC-01 hereof) has the following functions for DVP all series: 

• 

Read/write the program P, data register D and file register F from PLC. 

• 

Copy program and data. 

• 

Support the PLC password protection. 

 

Overview of the Product - Names of Parts

 

P: program area indication 
(TC-01) 

2  W: write (WR) indication (TC-01) 

3  R: read (RD) indication (TC-01) 

4  “In communication” indication 

D: Data Register indication 
(TC-01) 

F: File Register indication 
(TC-01) 

CR: Control Register indication 
(Extension Module) 

8  ER: Error message display 

9 Display 

Area 

10  Enter button 

 

indication 

11 

K (Decimal), H (Hexadecimal) 
indication 

12 

Contacts & coils of timer / 
counter indications 

13 

Word devices T, C, D, DD 

(32-bit) 

indication 

14  Bit devices X, Y, M, S indication 

15  Digit backspace / Run (TC-01) 

16  Back to previous status 

17  Enter number or select device 

18 Confirm 

ESC

OK

4

3

2

1

5
6
7
8

9

DU-01

 

19  Enter number or select device 

3  

INSTALLATION & WIRING 

 

1.  Direct mounting to the expansion slot in the MPU of 

the EP/EH series 

 

 

 

 

Please power down the PLC MPU prior to install the DU-01,
which is connected via a high-density connector. Also please 
refer to the figures above for proper operation.  Put the 
face-up DU-01 slantly in the extension slot, then push it down 
in arrow direction.   

DO NOT

 push it down vertically to prevent

damage.

 

2.  Connecting to DVP 

series PLC via accessory 
cable 

 

(No need to shut down the MPU)

 

4  

TS-01 OPERATION 

1. 

Switch DU-01 to TS-01 mode. (Please see the back of the DU-01) 

2. Main 

Process 

OK

ESC

ESC

OK

ESC

ESC

OK

OK

ESC

Time Mode

Press and hold for 3 sec.

Auto Save

Confirm & update time

Operation Mode

Display
Selection

No Save

YY-MM-DD

HH-MM-SS

  Device

Selection

Device Selection

X, Y, M, S

T, C, D

CR

DD(32-bit)

OK

OK

OK

OK

OK

OK

OK

ESC

ESC

ESC

ESC

ESC

  Device
  Monitor

   Bit
Device

 Word
Device

Device confirm

Device confirm

Number Selection

Specify a number

Force On/Off setting

Specified No.
    Display

Enter Set Value

Enter a number

Number Selection

Press

to complete entering & return

Monitor status of 8 consecutive 
devices from the specified number

Press and hold for 3 sec.

Press and hold for 3 sec.

Press and hold for 3 sec.

Press and hold for 3 sec.

 

3. 

Start-up display mode setting (press 

+

 

buttons simultaneously) 

Any mode*

Sleep mode

Monitor 

Mode

Press          +

 

Until              shows 

+

Time & device 

content

Sleep mode activated if no button is pressed
within 

30 seconds

*Note: not include system operation mode setting

 

4. 

Please see the back page for detail information about the process of each mode.   

5

TC-01 OPERATION 

 

1. Switch the DU-01 to TC-01 

mode (please see the back of 
the DU-01), and select RD (to 
read P, D and F in the MPU of 
PLC) or WR (to write the data 
in P, D, F of DU-01 to the MPU 
of PLC). 

TC-01

Indication of the connected MPU model

Indication of internal data storage model 

Note: P: Program, D: Data register, F: File register 

2. TC-01 Password Key Setting 

Password key setting of TC-01 can be set via WPLSoft. The purpose is to read/write to the key-locked 
PLC as long as the password setting matches with the one in PLC.    To unlock the password key 
setting, please use WPLSoft as well. 

a)  Password Key Setting 

 

In RD or WR mode, press ESC button and hold for 3 seconds or 
more to enter password setting.    See the figure on the right: 

 

Open WPLSoft   [Setting]   [TC-01 password key setting].   
Select [Enter TC-01 password key], and operate as instructed. 

 

After setting, display shows the figure on the right. (KEY SET), 
then press ESC to exit. 

b)  TC-01 has password key setting, therefore, only if the PLC has no password protection or with the 

same password with TC-01 can process the writing.    It also writes the password to the PLC for 
added protection. 

c)  Password key clear (KEY CLR): Same as the operation above. Open WPLSoft, select [TC-01 

password key clear], and operate as instructed. 

3. Clear P, D, F of TC-01: select the device (P, D or F) to be cleared, press

+

 simultaneously, 

then press ESC. 

4.  RD mode description: 

RD read mode

P,D,F selection

+

P(Program)

D (Data Register)

F (File Register)

Reading P (Program).

You can press ESC to 

pause reading.

Setting reading range.

 (default start & end 

addresses are  latched 

area range. User can 

re-set it.) 

Reading 

F (file register)

You can press ESC to 

pause reading.

Enter start address

Finish reading

Finish reading

Finish reading

Finish reading.

d1EC is the CHKSUM

of writing program

2746 is the CHKSUM

of writing data

Enter end address

Reading processing...
You can press ESC to 

pause reading.

Confirm
Device

 