Chapter 4 Parameters
|
4-50
Revision June 2008, 04EE, SW--PW V1.11/CTL V2.11
460V series
0.1 to 510.0V
Factory Setting: 440.0
01.34
Mid-Point Frequency (Fmid) (Motor 2)
Unit: 0.01
Settings 0.10 to 600.0Hz
Factory Setting: 1.50
01.35
Mid-Point Voltage (Vmid) (Motor 2)
Unit: 0.1
Settings 115V/230V series 0.1 to 255.0V
Factory Setting: 10.0
460V series
0.1 to 510.0V
Factory Setting: 20.0
01.36
Minimum Output Frequency (Fmin) (Motor 2)
Unit: 0.01
Settings
0.10 to 600.0Hz
Factory Setting: 1.50
01.37
Minimum Output Voltage (Vmin) (Motor 2)
Unit: 0.1
Settings
115V/230V series 0.1 to 255.0V
Factory Setting: 10.0
460V series
0.1 to 510.0V
Factory Setting: 20.0
01.38
Maximum Voltage Frequency (Fbase) (Motor 3)
Unit: 0.01
Settings
0.10 to 600.0Hz
Factory Setting: 60.00
01.39
Maximum Output Voltage (Vmax) (Motor 3)
Unit: 0.1
Settings 115V/230V series 0.1 to 255.0V
Factory Setting: 220.0
460V series
0.1 to 510.0V
Factory Setting: 440.0
01.40
Mid-Point Frequency (Fmid) (Motor 3)
Unit: 0.01
Settings 0.10 to 600.0Hz
Factory Setting: 1.50
01.41
Mid-Point Voltage (Vmid) (Motor 3)
Unit: 0.1
Settings 115V/230V series 0.1 to 255.0V
Factory Setting: 10.0
460V series
0.1 to 510.0V
Factory Setting: 20.0
01.42
Minimum Output Frequency (Fmin) (Motor 3)
Unit: 0.01
Settings
0.10 to 600.0Hz
Factory Setting: 1.50
01.43
Minimum Output Voltage (Vmin) (Motor 3)
Unit: 0.1
Settings
115V/230V series 0.1 to 255.0V
Factory Setting: 10.0
460V series
0.1 to 510.0V
Factory Setting: 20.0
The V/f curve of motor 0 to motor 3 can be selected by setting the multi-function input
terminals MI3~MI6 (Pr.04.05 to Pr.04.08) to 27 and 28.
Group 2: Operation Method Parameters
02.00
Source of First Master Frequency Command
Factory Setting: 1
02.09
Source of Second Master Frequency Command
Factory Setting: 0
Settings
0
Digital keypad UP/DOWN keys or Multi-function Inputs UP/DOWN.
Last used frequency saved. (Digital keypad is optional)
Содержание AC Motor Drive VFD-E
Страница 1: ......
Страница 2: ......
Страница 3: ......
Страница 13: ...This page intentionally left blank...
Страница 27: ...Chapter 1 Introduction 1 14 Revision June 2008 04EE SW PW V1 11 CTL V2 11 This page intentionally left blank...
Страница 233: ......
Страница 237: ...Appendix A Specifications A 4 Revision June 2008 04EE SW PW V1 11 CTL V2 11 This page intentionally left blank...
Страница 272: ...Appendix B Accessories Revision June 2008 04EE SW PW V1 11 CTL V2 11 B 35 B 11 DIN Rail B 11 1 MKE DRA...
Страница 274: ...Appendix B Accessories Revision June 2008 04EE SW PW V1 11 CTL V2 11 B 37...
Страница 275: ...Appendix B Accessories B 38 Revision June 2008 04EE SW PW V1 11 CTL V2 11 This page intentionally left blank...
Страница 349: ...Appendix D How to Use PLC Function D 66 Revision June 2008 04EE SW PW V1 11 CTL V2 11 This page intentionally left blank...