![DelRay MONTIGO DRL3613LI Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/delray/montigo-drl3613li/montigo-drl3613li_installation-and-maintenance-manual_2471113012.webp)
12
Installation
XG0226 - 042220
Section 3: Venting
Montigo offers a variety of direct venting and termination options. The
direct vent termination location MUST be selected such that it is the
highest point in the venting assembly. It should also be selected such
that it provides the shortest vent run possible. Should it be impossible
to ensure that the termination is the highest point or to meet the
venting guidelines laid out below please contact your Montigo dealer
to discuss power venting options.
Notes For Planning Venting:
• Venting originates from the top of the unit
• Venting can terminate through the roof or through an exterior wall.
• Refer to Appendix A - Termination Locations to ensure the planned
termination location is acceptable.
•
Once the termination location has been established, refer to the
appropriate section below for installation details
•
All fireplaces shipped from the factory are top vent.
• Silicone
application is
NOT
required when joining Montigo vent
pipes and components.
Under no circumstances can Montigo flex venting be cut to
accommodate an installation. Use an alternative length to complete
your vent run. (Excluding flex included in the MVK05 / MVK05F)
NOTICE
MVK05 / MVK05F
MVK05 / MVK05F Flex Vent Kit is a standalone 5' vent kit that
cannot be combined with Montigo Flex or Montigo Rigid pipe to
extend beyond the 5ft of flex included in this kit. The Flex in this
kit can be cut down if shortening is required. Any other venting
configuration beyond the 5ft included in the MVK05 kit will
require going to either Montigo Rigid pipe or Montigo Flex pipe
referenced in the manual pages Venting section.
Figure 4.a
MVK05 / MVK05F Flex Vent Kit
Содержание MONTIGO DRL3613LI
Страница 53: ...53 Notes XG0226 042220...