Profi
Message
Parameter
Symbol Calculation
Example
Recording time Recording time tr
tr = ns / fs
2048 / 2560 Hz
= 800 ms
Frequency
range
Frequency
range
fra
fra = fs /
2.56
2560 / 2.56 =
1000 Hz
Number of
lines
Number of
lines
nli
nli = ns /
2.56
2048 / 2.56 =
800
Frequency res-
olution
Frequency res-
olution
fre
fre = fs / ns
2560 Hz/ 2048 =
1.25 Hz
9.2.2.1
Redundant trigger source
When triggering takes place via an external digital signal, the trigger source can
be automatically switched in the event of a trigger signal failure. There are two
options:
l
1-level redundancy
There is a switch to the time-period trigger if a trigger signal on digital-input
fails.
l
2-level redundancy
There is a switch to the trigger signal on digital input 2 if the trigger signal
on digital input 1 fails. If digital-input 2 also fails, there is a switch to the
time period trigger.
Configuration examples:
255
Delphin Technology AG
Dezember 2015
Profi
Message Manual
Содержание ProfiMessage
Страница 1: ......
Страница 31: ...ProfiMessage 3 5 4 ADIT 31 Delphin Technology AG Dezember 2015 ProfiMessage Manual ...
Страница 32: ...ProfiMessage 3 5 5 ADVT 3 5 6 AMDT 32 Delphin Technology AG Dezember 2015 ProfiMessage Manual ...
Страница 33: ...ProfiMessage 3 5 7 DIOT 3 5 8 IOIT 33 Delphin Technology AG Dezember 2015 ProfiMessage Manual ...
Страница 234: ...ProfiMessage Block diagram for an analogue input signal 234 Delphin Technology AG Dezember 2015 ProfiMessage Manual ...
Страница 312: ...ProfiMessage 11 Appendix 11 1 ISO 9001 certificate 312 Delphin Technology AG Dezember 2015 ProfiMessage Manual ...
Страница 313: ...ProfiMessage 11 2 EC declaration on conformity 313 Delphin Technology AG Dezember 2015 ProfiMessage Manual ...
Страница 314: ...ProfiMessage 314 Delphin Technology AG Dezember 2015 ProfiMessage Manual ...
Страница 322: ......