Users Operating Instructions

Before operating this hob, 

please read these instructions carefully

GB

Содержание GHS 261 ST

Страница 1: ...GHS 261 ST gas hob Users Operating Instructions Before operating this hob please read these instructions carefully GB...

Страница 2: ...Low Voltage Directive 73 23 EEC Protection requirements of the EMC Directive 89 336 EEC Requirements of Directive 93 68 EEC These instructions are only valid for those countries whose identification...

Страница 3: ...dangerous The manufacturer cannot be considered responsible for damage caused by improper incorrect or irresponsible use of the appliance Before disposing of any unwanted appliances it is recommended...

Страница 4: ...ary burner A 1 00 kW 2 Right medium speed burner SR 1 75 kW 3 Left medium speed burner SR 1 75 kW 4 Rapid burner R 3 00 kW CONTROL PANEL 5 Rapid burner control knob 4 6 Left medium speed burner contro...

Страница 5: ...erture position allows slower warming of food or maintaining boiling conditions of liquids To reduce the gas flow to minimum rotate the knob further anti clockwise to point the indicator towards the s...

Страница 6: ...se direction up to the maximum aperture symbol press the knob right down to prime the electric ignition until the burner lights In case of power cut manually light the burner Adjust the burner accordi...

Страница 7: ...ight of the pan are safer as they are less likely to tip Pans which are positioned centrally on burners are more stable than those which are offset It is far safer to position the pan handles in such...

Страница 8: ...ather Note regular use will cause discolouring around the burners because of the high flame temperature BURNERS AND GRIDS These pieces can be removed and washed with suitable products After cleaning b...

Страница 9: ...to check that spreader F and cap C of the burner see Figures 5 and 6 are perfectly in place because if they move out of place serious problems could arise Make sure that electrode S Fig 5 is kept clea...

Страница 10: ...does not light check the ignition is working if not check the 3 amp fuse make sure gas is turned on make sure burner caps are in Position correctly After Sales Service Should you require to book a ser...

Страница 11: ...ce to remain in contact with enamel parts Do not use abrasive cleaners or powders that will scratch the stainless steel surface Do not attemt to repair the internal workings of the hob Always consult...

Страница 12: ...and following the manufacturer s instructions Any repair or maintenance must be performed with the appliance switched off These appliances have been designed and manufactured to be fitted into heat r...

Страница 13: ...is a wall unit or hood above the hob there must be at least 750 mm between the hob and the unit or hood see also Fig 8 If the hob is not installed over a built in oven it is essential to install a hea...

Страница 14: ...screws to fasten it to units from 2 to 4 cm thick Turn the hob over and put tabs A into the mountings only tighten screws B a few turns Do not over tighten Make sure that the tabs are correctly mounte...

Страница 15: ...pening to the outside All rooms require an openable window or equivalent while some rooms require a perma nent vent in addition to a window that can be opened This unit must not be used in a room with...

Страница 16: ...th the Gas Safety Installation and Use Amendment Regulation 1990 and the relevant Building I E E Regulations The following British Standards should be used as reference when installing this appli ance...

Страница 17: ...cookers After connecting to the mains check that the coupling are correctly sealed using soapy solution but never a flame GAS CONNECTION The installation of the hob to Natural Gas or LP Gas must be ca...

Страница 18: ...To replace the injectors proceed as follows Remove pan supports and burners from the hobtop By a spanner remove the injector J fig 12 from its housing and replace it by the proper one according to th...

Страница 19: ...Air necessary for combustion m3 h Auxiliary A 2 00 Semi rapid SR 3 50 Rapid R 6 00 Cat II 2H3 Hs kW Hs kW injector injector 1 100 mm 1 100 mm Auxiliary A 1 00 0 30 50 72 X Semi rapid SR 1 75 0 45 65...

Страница 20: ...sting the minimum gas rate setting is described below For taps with adjusting screw inside the shaft fig 13 using a screwdriver max diameter 3 mm turn the screw inside the tap shaft until the flame se...

Страница 21: ...cut off plug should be disposed of safely to prevent the hazard of electric shock There is a danger of electric shock if the cut off plug is inserted into any 13 amp socket outlet How to wire a 13 am...

Страница 22: ...t are given as simply indicative The manufacturer reserves the right considering the characteristics of the models described here at any time and without notice to make eventual necessary modification...

Страница 23: ...23...

Страница 24: ...cod 1102433 3...