background image

16

I m p o r t a n t   s a f e g u a rd s

Use this appliance only as described in this instruction manual.
As with any electrical appliance, whilst the instructions aim to cover as many eventualities as
possible caution and common sense should be applied when operating and installing this air
conditioner.

This appliance has been manufactured to cool and de-humidify domestic environments and
should not be used for other purposes.

It is dangerous to alter or modify the unit's characteristics in any way.

The appliance must be installed in line with the relevant national legislation.

Should repairs be necessary, contact the nearest authorised Repair Service Centre. Unautho-
rised servicing can be dangerous.

This appliance is to be used by adults only; keep away from children.

In the case that the power cable becomes damaged, this must be substituted only by specialised
personnel authorised by the manufacturer.

Always ensure the appliance is earthed. If you have any doubts check with a qualified elec-
trician.

Avoid using extension leads with the unit.

Before cleaning or maintenance operations, always unplug the unit from the socket.

Do not pull on or place strain on the power cable when moving the appliance.

The appliance should not be installed where the atmosphere may contain combustible gases,
oil or sulphur, or near heat sources.

If the appliance is utilised in areas where there is no ventilation of air, it is necessary to take pre-
cautions to avoid that the refrigerant gases that may leak from the appliance do not remain
in the room, thereby causing a fire hazard.

This appliance must be utilised and installed only in rooms with a total volume of 15 cubic metres
or greater. 

•  The refrigerant used in this appliance would cause damage to the ozone layer if relased into the

atmosphere. Therefore at the end of the working life of the appliance the unit should be taken to
a recycling centre for disposal of the refrigerant.

•  Keep the unit at least 50 cm away from inflammable substances (alcohol etc) or pressurised con-

tainers (eg. aerosol cans).

Do not rest hot or heavy objects onto the appliance.

Clean the filters at least once a week.

Remember to perform the descaling procedure at the end of each season (see page 25).  In
areas where the water is particularly hard (rich in minerals), the use of a commercial anti-lime
product added to the water is recommended.  This can be requested from De’Longhi LTD.

Avoid using heaters near the unit.

Do not cover this appliance with bags when is not in use

Unventilated area where the appilance using flammable refrigerants is installed shall be  so con-
structed that any leaked refrigerants will not stagnate so as to cause a fire or an explosion hazard
caussed by igniting stagnant refrigerants from other source such as electric heater, stove and simi-
lar home applications.

The unit should be transported in a vertical position. If this is not possible secure the unit at an
angle, do not lie horizontally.
Before transporting the unit drain the condensation collecting-tray and tank. After transporta-
tion, wait at least 1 hour before switching on the unit.

The packaging materials can be recycled. You are therefore recommended to place them in
the special containers for differentiated waste collection.

GB-5751010800  26-01-2004  16:26  Pagina 16

Содержание PAC 46ECO

Страница 1: ...y causing a fire hazard This appliance must be utilised and installed only in rooms with a total volume of 15 cubic metres or greater The refrigerant used in this appliance would cause damage to the o...

Страница 2: ...into the room In single unit models Pinguino a small part of this air is used to cool the refrigerant gas befo re hot and moist air is being discharged outside In suitcase models the cir cuit is coole...

Страница 3: ...the exhaust hose to the coupling on the back of the unit as shown in figu re A 10 22 With a double casement window use the suckers provided to hold the two hal ves of the window together fig C 24 Fix...

Страница 4: ...tside wall or through the glass of a window Check the height and dimensions given in figure D 30 cm 30 cm 106 MAX 120 cm MIN 30 cm When the hose is not attached close the hole with the bung on the fla...

Страница 5: ...To open the front panel grip either side of the panel and gently pull the panel towards you and upwards Remove the tank Lifting it forward 6 4 B Turn the tank upside down and remove the plug remove t...

Страница 6: ...ointer N B Never turn the dial in an anti clockwise direction The timer is in effect an electric clock and works only if the plug is connected to the power supply Whenever the plug is discon nected or...

Страница 7: ...ery warm room quickly down to a more comfor table level In this case Make sure that the tank is full of water see page 22 Make sure that the function selector switch is in the large crystal position 1...

Страница 8: ...Do not obstruct the air intake or outlet Make sure there are no heat sources in the room Do not use outdoors 2 8 PROBLEM WARNING LIGHT The lighted pilot light indicates that the safety device of the p...

Страница 9: ...following method turn off the appliance and remove the plug from the electrical outlet open the front panel and remove the tank remove the bung from the drainage hose which can be found at the back th...

Страница 10: ...ur 4 After this drain out all of the liquid remai ning in the collection reservoir and rinse thoroughly During the rinsing process the drainage hose must be open and the appliance functioning 5 Unplug...

Страница 11: ...people the air outlet hose has come detached from the coupling thermostat adjusted too high air filters clogged the output of the unit is insufficient for the con ditions or size of the room wait thr...

Страница 12: ...he fuse using a 13 Amp Asta approved fuse to BS 1362 In the event of losing the fuse cover the plug must NOT be used until a replacement fuse cover can be obtained from your nea rest electrical dealer...