11
REPLACING THE POWER SUPPLY CABLE
Important! This appliance must be connected to the electricity supply only by an
authorised person.
To connect the supply cable:
■
Unhook the terminal board cover by inserting a screwdriver into the two hooks “
A
” (fig. 4).
■
Unscrew the screw “
D
” and open completely the cable clamp “
E
” (fig. 5).
■
Connect the phase, neutral and earth wires to terminal board “
G
” according to the
diagram in fig. 6.
■
Strain the feeder cable and block it with cable clamp “
E
” (by screwing screw “
D
”).
■
Close the terminal block cover (check the two hooks “
A
” are correctly hooked).
N.B. The earth conductor must be left about 3 cm longer than the others.
VOLTAGE AND POWER CONSUMPTION
220-240 V ac
2600 W (11.30 A)
FEEDER CABLE SECTION
TYPE H05RR-F
3 x 1,5 mm
2
(*) (**)
(*) Connection possible with plug and outlet
(**) Connection with wall box connection.
Figure 5
Figure 4
Figure 6
A
1
2
3
5
4
N
L2
PE
L1
G
D
E
L
N
PE
N
L
220-240 V ac