25I DELLMECO I EODD DIAPHRAGM PUMPS
6. Installation and mounting
6.1. Installing the DME Pump
Decide where the pump is to be installed and secure a site. The DME Pump installation place have to meet the
following requirements:
-
The suction lift should be kept as short as possible.
-
Sufficient space around the pump for maintenance must be provided. Free space required for the mounting and
disassembly of the pump and the unit
– at least 0.5 m up to 1.0 m (for all DME pump sizes) on all sides.
-
The pump can be operated without fastening to a foundation. However, in the event that a fastening is provided,
the fastening must be stress-free and must be made at the pump or engine support only. In that case use the
cushions on the pump base. The tied-down bolts should be tightened from time to time, to secure the pump.
TYPES OF INSTALLATION
SELF PRIMING APPLICATION
Suction lift capability may vary depending on the construction materials and
application parameters. The range is from 3 meters dry to 8 meters in a primed
condition (values calculated for pumping water at 20 degrees Celsius).
POSITIVE SUCTION HEAD
Common as a method of drawing off the bottoms of holding tanks and
clarifiers. Optimum inlet pressure should be kept at 0.2-0.3 bar.
!
CAUTION
When installing accessories prevent any foreign matter from getting into the product.
Otherwise malfunction of the pump may follow.
Содержание DME 15 R Series
Страница 11: ...11I DELLMECO I EODD DIAPHRAGM PUMPS 5 2 DME 40 50 R Z and DME 80 R Plastic Series Diaphragm Pump exploded view...
Страница 14: ...14 I DELLMECO I EODD DIAPHRAGM PUMPS 5 3 DME 20 25 40 A C S Metal Series Diaphragm Pump exploded view...
Страница 15: ...15I DELLMECO I EODD DIAPHRAGM PUMPS 5 4 DME 50 A C S Metal Series Diaphragm Pump exploded view...
Страница 16: ...16 I DELLMECO I EODD DIAPHRAGM PUMPS 5 5 DME 80 A B Metal Series Diaphragm Pump exploded view...
Страница 17: ...17I DELLMECO I EODD DIAPHRAGM PUMPS 5 6 DME 80 S Metal Series Diaphragm Pump exploded view...
Страница 20: ...20 I DELLMECO I EODD DIAPHRAGM PUMPS 5 7 DME 25 40 50 H Hygienic Series Diaphragm Pump exploded view...
Страница 21: ...21I DELLMECO I EODD DIAPHRAGM PUMPS 5 8 DME 65 H Hygienic Series Diaphragm Pump exploded view...
Страница 22: ...22 I DELLMECO I EODD DIAPHRAGM PUMPS 5 9 DME 80 H Hygienic Series Diaphragm Pump exploded view...
Страница 39: ...39I DELLMECO I EODD DIAPHRAGM PUMPS DME Plastic Series Flow Characteristics...
Страница 43: ...43I DELLMECO I EODD DIAPHRAGM PUMPS DME Metal Series Flow Characteristics...
Страница 45: ...45I DELLMECO I EODD DIAPHRAGM PUMPS DME Hygienic Series Flow Characteristics...
Страница 65: ...Notes...
Страница 66: ...DELLMECO Swierkowa 2 Glincz 83 330 POLAND tel 48 532 720 222 sales dellmeco com www dellmeco com...