Product Safety, EMC & Environmental Datasheet
Page 4
VIII. PERFORMANCE DATA
Energy Consumption
4
Service Level
Energy
Consumption
(Wattage)
BTU
Calculation
Description of Service Level
Maximum 24.85 84.987
The system is running programs to maximize the power
consumption
On mode
21.3
72.846
The product is connected to a power source and
produces an image
Sleep Mode
0.52
1.7784
The reduced power state the display enters after
receiving instructions from a content source (e.g.
computer, game console, or set-top box), or via other
functions (e.g. timers or sensors). A blank screen and
reduction in power consumption characterize this mode.
The display returns to On Mode with full operational
capability upon sensing a signal from a source or function
that can initiate that can initiate the reduced power state.
Off 0.42
1.4364
The system is turned off but is still connected to its AC
power source
Energy consumption is tested at 230 Volts / 50 Hz. Heat dissipation is calculated based on the measured watts, assuming the
service level is attained for one hour. Off data is not meant to show compliance to US Executive Order 13221. When
applicable, Dell product information related to US Executive Order 13221 may be obtained at:
http://oahu.lbl.gov/index.html
.
4
This document is informational only and reflects laboratory performance. Your product may perform differently, depending on the software, components and
peripherals you ordered. Accordingly, the customer should not rely upon this information in making decisions about electrical tolerances or otherwise. No warranty
as to accuracy or completeness is expressed or implied.