![Dell SC4020 Скачать руководство пользователя страница 103](http://html.mh-extra.com/html/dell/sc4020/sc4020_deployment-manual_79827103.webp)
b. Run the following commands to set the BMC IP address, netmask, and gateway.
platform bmc set ip <
IP address
>
platform bmc set netmask <
netmask
>
platform bmc set gateway <
gateway address
>
Example:
platform bmc set ip 169.254.0.1
platform bmc set netmask 255.255.255.0
platform bmc set gateway 0.0.0.0
6.
Run the following command to verify that the prejoin configuration information is correct.
platform prejoin show
If the prejoin information is incorrect, re-enter the information and verify it again.
7.
Run the following command to exit Safe Mode and boot up the storage controller.
-sm -go
NOTE: The storage controller might take several minutes to completely boot up. During this
time, there are long pauses that might make the storage controller appear to be idle. However,
the long pauses are part of the normal boot process. When the storage controller finishes
booting up, the following message is displayed in the terminal emulator:
All subsystems
initialized successfully.
CAUTION: Wait for the top storage controller to finishing booting before configuring the
bottom storage controller. If you configure the bottom storage controller before the top
storage controller has finished booting, the bottom storage controller may not configure
correctly.
CAUTION: As the storage controller boots up, a login prompt may appear in the terminal
emulator. Do not log in to the storage controller with the Admin account at this time.
Logging in with Admin account before the storage controller subsystems are fully initialized
may cause the Admin account to become locked.
CAUTION: Do not log in to the Storage Center System Manager (GUI) until both storage
controllers are configured and fully booted. Logging in to the Storage Center System
Manager at this time in the deployment procedure causes the Startup Wizard to start before
the bottom storage controller is configured.
Establish a Serial Connection to the Bottom Storage
Controller
Create a serial connection from a computer to the bottom storage controller.
1.
Use the supplied RS232 serial cable (DB9 female to 3.5 mm male adapter) to connect a computer to
the 3.5 mm serial port on the bottom storage controller.
To connect from a computer with a USB port, use a USB to DB9 male serial adapter.
2.
Open a terminal emulator program on the computer.
NOTE: Make sure to enable logging in the terminal emulator. If an issue occurs during the
storage system deployment, save a copy of the log file to allow for troubleshooting.
3.
Configure the serial connection in the terminal emulator as shown in the following table.
Set up Storage Center Software
103
Содержание SC4020
Страница 1: ...Dell Storage Center SC4020 Storage System Deployment Guide ...
Страница 170: ...170 Adding or Removing an Expansion Enclosure ...
Страница 178: ...178 HBA Server Settings ...
Страница 182: ...182 iSCSI Settings ...