Dell Networking S4100-ON Series

Set-Up Guide

Содержание S4100-ON Series

Страница 1: ...Dell Networking S4100 ON Series Set Up Guide ...

Страница 2: ... to hardware or loss of data and tells you how to avoid the problem WARNING A WARNING indicates a potential for property damage personal injury or death Copyright 2017 Dell Inc or its subsidiaries All rights reserved Dell EMC and other trademarks are trademarks of Dell Inc or its subsidiaries Other trademarks may be trademarks of their respective owners 2017 07 Rev A00 ...

Страница 3: ...Rack or cabinet installation 10 Rack mount safety considerations 10 ReadyRails installation 10 1U Tool less mount installation 11 Two post flush mount installation 12 Two post center mount installation 13 Four post threaded installation 14 S4100 ON Series system installation 15 1U front rack installation 15 Optics installation 17 Optics removal 18 System power up 18 Power up sequence 18 After syst...

Страница 4: ...ed visible and invisible laser radiation may be emitted from the aperture of the optical transceiver ports Avoid exposure to laser radiation Do not stare into open apertures Topics Related documents Information symbols Related documents For more information about the S4100 ON Series see the following documents Dell Networking OS10 Enterprise Edition Release Notes Dell Networking OS10 Enterprise Ed...

Страница 5: ...The Warning icon signals information about hardware handling that could result in injury WARNING The ESD Warning icon requires that you take electrostatic precautions when handling the device About this guide 5 ...

Страница 6: ...e area where you install your S4100 ON Series switch meets the following safety requirements Near an adequate power source Connect the system to the appropriate branch circuit protection according to your local electrical codes Environmental switch location continuous temperature range is from 50 to 104 F from 5 to 40 C Operating humidity is from 5 to 85 percent noncondensing continuous In a dry c...

Страница 7: ...he I O reverse Be sure to order the fans suitable to support your site s ventilation Use a single type of airflow fan in your system Do not mix reverse and normal airflows in a single S4100 ON Series switch For proper ventilation position the S4100 ON Series switch in an equipment rack or cabinet with a minimum of 5 inches 12 7 cm of clearance around the exhaust vents The fan speed varies based on...

Страница 8: ...s from 40 to 149 F 40 to 65 C Store on a dry surface or floor away from direct sunlight heat and air conditioning ducts Store in a dust free environment NOTE ESD damage can occur when components are mishandled Always wear an ESD preventive wrist or heel ground strap when handling the S4100 ON Series switch and its accessories After you remove the original packaging place the S4100 ON Series switch...

Страница 9: ...ack the system Unpack Rack or cabinet installation ReadyRails installation 1U Tool less mount installation Two post flush mount installation Two post center mount installation Four post threaded installation S4100 ON Series system installation 1U front rack installation Optics installation Optics removal System power up After system installation Unpack the system NOTE Before unpacking the system i...

Страница 10: ...siderations Connect only to the power source specified on the unit When you install multiple electrical components in a rack ensure that the total component power ratings do not exceed the circuit capabilities Overloaded power sources and extension cords present fire and shock hazards Elevated ambient temperature If you install the switch in a closed rack assembly the operating temperature of the ...

Страница 11: ...hed to the rail assembly 1 Face the ReadyRails flange ears facing outward Place one rail between the left and right vertical posts Align and seat the back flange rail pegs in the back vertical post flange The center extractions show how the pegs appear in both the square and nonthreaded round holes S4100 ON Series installation 11 ...

Страница 12: ... rail Two post flush mount installation NOTE For more installation instructions see the installation labels attached to the rail assembly 1 For this configuration remove the latch castings from the front side of each ReadyRails assembly item 1 To remove the two screws from each front flange ear on the switch side of the rail and remove each latch casting use a Torx screwdriver Retain the latch cas...

Страница 13: ...to the post flange with two user supplied screws see item 3 4 Repeat this procedure for the second rail Two post center mount installation NOTE For more installation instructions see the installation labels attached to the rail assembly 1 Slide the plunger bracket rearward until it clicks into place and secure the bracket to the front post flange with two user supplied screws item 1 S4100 ON Serie...

Страница 14: ...ocedure for the second rail Four post threaded installation NOTE For more installation instructions see the installation labels attached to the rail assembly 1 Remove the latch castings from each end of the ReadyRails assemblies To remove the two screws each latch casting use a Torx driver Retain the latch castings for future rack requirements 14 S4100 ON Series installation ...

Страница 15: ...or the 1U two post configurations slide the system into the rails in the same manner as the four post configurations 1U front rack installation Configure the rails that are attached to the system 1 NOTE For more information see the installation instruction labels on the rail Attach the inner switch rails to the S4100 ON Series switch Line up the rail with the mounting heads and attach the rail to ...

Страница 16: ... them up on the ReadyRails Slide the switch in until it is flush with the front of rack About three inches before you fully insert your system the rail locking feature engages to keep the switch from inadvertently sliding out and falling 16 S4100 ON Series installation ...

Страница 17: ...ts are mishandled Always wear an ESD preventive wrist or heel ground strap when handling the S4100 ON Series and its components WARNING When working with optical fibers follow all warning labels and always wear eye protection Never look directly into the end of a terminated or unterminated fiber or connector as it may cause eye damage 1 Position the optic so it is in the correct position The optic...

Страница 18: ...ient airflow around the unit The input circuits are correctly sized for the loads and that you use sufficient overcurrent protection devices All protective covers are in place Blank panels are installed if you do not install optional modules CAUTION Do not power up the switch if you did not install a fan module NOTE A US AC power cable is included for powering up an AC power supply You must order ...

Страница 19: ... 2 inches 462 mm Handle 1 57 inches 40 mm Chassis weight with factory installed components 19 lbs 2 PSUs 8 62 kg 2 PSUs Rack clearance required Front 5 inches 12 7 cm Back 5 inches 12 7 cm Table 2 Environmental parameters Parameter Specifications Operating temperature 5 to 40 C 50 F to 104 F continuously 5 C to 45 C 23 F to 113 F short term Short term is 1 of operational hours per year NOTE Reduce...

Страница 20: ...pecifications Power supply 100 240 VAC 50 60 Hz Maximum current draw per system 6A 5A at 100 120V AC 3A 2 5A at 200 240V AC Maximum power consumption 600 Watts Typical power consumption 300 Watts Table 4 DC power requirements Parameter Specifications Minimum and maximum input voltage range 40 5 60V DC 15A Max Maximum Input current 40 5V 15A 48V 12 5A 60V 10A without fan Start up VDC 39 0 1 5 V Sta...

Страница 21: ... the web page and select your country from the drop down menu To obtain product specific information enter the 7 character service tag found on the luggage tag or the 11 digit express service code of your switch and click Submit To view the switch service tag or express service code pull out the tag or enter the show chassis command from the CLI The luggage tag is on the PSU side of the system To ...